...Precor Error 29, Excessive AC Input Current Probable Cause 1. The running belt and/or deck are badly worn. 2. Bad lower PCA. 3. Drive motor is shorted or de-magnetized causing a high power demand. ...
...Precor Error 29, Excessive AC Input Current Probable Cause 1. The running belt and/or deck are badly worn. 2. Bad lower PCA. 3. Drive motor is shorted or de-magnetized causing a high power demand. ...
PRECOR 927 TREADMILL WHAT DOES SPEED ERROR ON PRECOR 927 TREADMILL MEAN? I had the speed error on my precor 9.23. When I opened it up I found that there are two little round magnets on the belt&
Precor 933i belt error Treadmill started getting belt errors a couple of days ago. Everything I read online said it was friction of the belt and deck. Flipped the deck today and started the treadmill.
Question about C956i Treadmills with HR / WholeSale
...treadmill that is known to have a good running belt and deck. Replace the belt and/or deck if necessary. Don't forget, some units have a double sided deck which means it may be flipped over rather ...
Question about Treadmill Precor C954 (Used)
...treadmill stops wen runing and brings up er 27 on screen I tried tighting the belt but it hasent worked. but feels like it sliping Precor Error 27, Too Much Drive Motor Current Probable Cause 1. The ...
Question about Treadmill Precor C954 (Used)
treadmill stops wen runing on it and brings up er 27 on screen ive tightened belt but no dif Precor Error 27, Too Much Drive Motor Current Probable Cause 1. The running belt and/or deck are badly worn
treadmill stops wen running on it and brings up er 27 ive tried tighting belt but no dif Precor Error 27, Too Much Drive Motor Current Probable Cause 1. The running belt and/or deck are badly worn. 2.
...If so, there may be a problem with the upper - contact Precor and have them look up bulletins on that model/SN. If no belt movement, then there is a problem with either motor or MCB, probably
...Precor Error 29, Excessive AC Input Current Probable Cause 1. The running belt and/or deck are badly worn. 2. Bad lower PCA. 3. Drive motor is shorted or de-magnetized causing a high power demand. ...