Questions & Answers for: Jandy gas adapter

Question about Laars Hi - E2 350,000 Btu Heater

1 Answer

heater will not heat blower comes on gas valve clicks igniter bar glows but will not burn gas. If you dont smell any gas make sure that all gas valves between the heater and the main gas meter are ...

Ad

Question about Lite 2 Natural Gas Pilot Light Heater

0 Answer

...2 CODE HEATER STARTS TO CYCLE IGNITION GLOWS BUT NO FLAMES TO START. ANY TOUBLE SHOOTING TIPS check gas flow, check for cobwebs in gas orfices also check if 24 volts ac to the brown gas lead if not ...

Ad

Question about Lite 2 Natural Gas Pilot Light Heater

1 Answer

need to run a lite2 250n on lpg can i just adjust the gas pressure ?? No, you'll need an adapter kit to change the orrifices.

Question about Laars LX Pool Heater / 400,000 BTU / Natural Gas

0 Answer

what does it mean when gas pool heater states "service gas" not enough gas pressure or gas valve bad

Question about Lite 2 Natural Gas Pilot Light Heater

0 Answer

...fl 6 Does error FL 6 always mean that the control board is bad - or could it be another problem?? gas signal being sent to gas valve not by controller either stuck gas valve or bad control ...

My Jandy lite 2 natural gas heater has a loud clicking noise. It fires up and heats my pool nicely. My problem is.... as it is heating there is a loud clicking noise from the gas valve area. It acts a

Question about LXI 400 NATURAL GAS POOL HEATER -

1 Answer

Control panel is blank and the gas company checked the pressure, it is at 5. The heater is not activated. first of all, if the inlet gas pressure was only 5 inches water column the heater will under ...

Jandy Lite 2 is showing FL4 My igniter is turning red but no flame. DO I hve a gas problem? When I turn on the system, it sends power to the igniter which you can see turn red, after 10 seconds the ...

Question about Lite 2 Natural Gas Pilot Light Heater

0 Answer

Can FL2 be caused by running out of gas ( it is an LP Gas heater ) either by running out of gas or pump being turned off while heater is on turn heater off then back on should restart

I have a Jandy 125 pool heater and it runs for a few minutes and the gas valve starts to chatter and then goes off and locks out. It sounds like low gas pressure. check gas pressure if ok possible bad

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Jandy Pool and Spa Experts

David Spradling
David Spradling

Level 3 Expert

13520 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

john h

Level 3 Expert

29494 Answers

Are you a Jandy Pool and Spa Expert? Answer questions, earn points and help others

Answer questions