Questions & Answers for: Pentair no gas

Question about Minimax Ch 250,000 Btu Natural Gas Pool Heater Millivolt Ignition

1 Answer

the pilot come on but not the burners is t gas valve on is t tem on high ? 24 v at t brown wire at t gas valve replace gas valve if not replace ignitor

Ad

Question about Minimax Ch 250,000 Btu Natural Gas Pool Heater Millivolt Ignition

1 Answer

Jet size differnce from natural gas to bottled Hi, i am wondering if anyone could tell me the differences in the jet size from a natural gas mini max 250 to a bottled gas. Mini max 250 You will need ...

Ad

Question about 250k Minimax Ch Ng Mv Heater

1 Answer

...light and electronic ignighter just continually sparks but burners do not light up? I've checked gas, etc but just won't light. Any suggestions? Do burners need replacing? Heater is 8yrs old Do

Question about Minimax Ch 250,000 Btu Natural Gas Pool Heater Millivolt Ignition

2 Answers

is there any difference in bottle gas heater and natural gas heater by bottle i am assuming you mean propane. yes there is a difference , natural gas is mostly methane gas (ch4) a very small molecule,

Question about Minimax NT Heater

1 Answer

Smell Gas I smell gas periodically when using the heater for the pool or spa then it will go away. Is there something simple I can check or should I call the gas company? If you are smelling gas it is

Question about Minimax NT Heater

1 Answer

...for pool spa are illuminated, looks like it is shut down, somehow. Check to be sure that your gas valves are on at the house or tanks and outside and inside the heater. Then be sure to bleed

Question about MiniMax 100 Aboveground 100,000 BTU Propane Gas Electronic Heater

2 Answers

Pentair Minimax 100 . Natural gas. Milivolt type. Bypass closed. Bled limne until I smelled gas. Sparker is working but won't light at all. Seems there must not be any gas to pilot. Suggestions? ...

Question about MasterTemp high Performance Gas Heater 200 BTU ()

1 Answer

My mater temp is only 2 months old and has stopped working. The gas pressure in drops from 7.5 to 0 when the valve opens. I have had the gas compnay replace the meter and regulator with no lcuk. There

Mastertemp 400 NG heater - unused gas smell when firing whenever we turn on our pool heater, there is a smell coming from the heater that smells like gas. The gas company has determined it to be ...

pentair mastertemp 250 NA. heater will not fire, no error codes. starts fine, gas flows, igniter heating but still will not fire. It has a new valve, gas pressure entering valve from new regulator is ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Pentair Pool and Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Brad Brown

Level 3 Expert

19187 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Pentair Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides