...exposure lamp or inverter board that powers the lamp. Try lifting up the Document feeder so you can see the optics frame through the platen glass and turning off and then on, the main power switch to ...
exposure lamp problem. To try and correct, turn OFF the copier and then unplug from the wall. Wait 10 seconds and plug it back into the wall, then turn on the copier. Watch to see if the exposure lamp
...wires have been change. what do i do next? Exposure lamp Cable,or transfer corona.Is the expo lamp lighting??? if no there is posible three options -exposure lamp cable -exposure lamp -thermo ...
Question about 1360 Black and White Copier
...exposure lamp luminosity 2. defective engine pcb 3 incorrect shading position 4. defective CCD unit check exposure lamp harness connections; adjust position of contact glass shading plate or ...
...exposure lamp or inverter board that powers the lamp. Try lifting up the Document feeder so you can see the optics frame through the platen glass and turning off and then on, the main power switch to ...
...Exposure lamp error 1- check the Exposure lamp if it damage replace it . 2- check the Exposure lamp fuse ( located in scanner ) 3- check the Exposure harness . and after you solve your problem you ...
Question about Aficio 1022 All-In-One Laser Printer
Exposure Lamp Error Symptom: The standard while level was not detected properly when scanning the white plate. Possible Cause: • Exposure lamp defective • Exposure lamp stabilizer defective • Exposure
...E0061-001 Pre-exposure lamp Does the pre-exposure lamp turn on during copying operation? Check the wiring from the DC driver PCB to the pre-exposure lamp; if normal, replace the pre-exposure
...Exposure lamp problem • Check the CCD input value for the lighting status of the exposure lamp 100 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure ...
...exposure lamp on the copiers is failing or has failed , change it C400 is exposure lamp fails to come on; on start up the main exposure lamp should come on and do a scan. If the lamp is not detected ...