the water heater has heated up and shuts off current to top element. Only one element at a time can be on. If current still does not go to bottom AFTER top element shuts off, the top stat could be bad
Question about WH40 - Water Heater Time Switch - NEMA 1 Indoor Steel Case - DPS
the dial - twist it in either direction so that the pointer is on the current time of day. Release the dial to it's original (in) position. You can get the manual here. Please rate this reply - thanks
Question about WH40 - Water Heater Time Switch - NEMA 1 Indoor Steel Case - DPS
Get a electric water heater or not? I currently have a boiler w/hot water coil for domestic water. Wanted to know if it's worth shutting down the boiler for the off-heating months and using an ...
Question about WH40 - Water Heater Time Switch - NEMA 1 Indoor Steel Case - DPS
...current time with the pointer. Let the dial return to the original (in) position. You'll have to do this whenever DST changes and after power outages. The manual for the WH40 can be downloaded for ...
Question about 81VP15S Point-of-Use Electric Water Heater, 15 Gallon, 120v
...time because of a resistive joint in the block getting hot due to the high current that water heaters consume. It seems that the element has failed if the reset button does not get the system
Question about 81VP15S Point-of-Use Electric Water Heater, 15 Gallon, 120v
...current, the gas will stop flowing and the pilot light will go out. This is a pretty common failure on water heaters and furnaces. Replacement of the thermocouple is fairly simple if you are the ...
Question about 81VP15S Point-of-Use Electric Water Heater, 15 Gallon, 120v
current time, rotate the dial and fudge current time by 10-12 hours so water heater thinks it's time for boost, but the actual time is during off-peak hours. If terminals 4 and 5 both have wires, then
Question about 81VP15S Point-of-Use Electric Water Heater, 15 Gallon, 120v
...current and gas control valve shuts off gas to heater. Moreover, the new gas control valve can be repaired and replaced without removing from tank. So tank does not have to be drained... saving time ...
Question about 81VP15S Point-of-Use Electric Water Heater, 15 Gallon, 120v
...could sweat from time to time ..
depends on installation /location /current climate and ambient temperatures
NO not normal
if water is near wiring or running down the side seams or ...
Question about 81VP15S Point-of-Use Electric Water Heater, 15 Gallon, 120v
...current required for instant hot water may be switched via a relay or contacter which may be faling. One way to diagnose may be with cover off and careful listening and visual inspection, but a risky ...