Carrier 58MVP; Blower on, no heat. Themosta at 75, temp at 69 and furnace still does not come on. Fault code 12 A code 12 is "Blower on after power-up" Try resetting the furnace with either the ...
Question about Carrier Heating & Cooling
...Carrier 58GP075-3 furnace The burners come on and run tell the blower kicks on, at the exact same time blower comes on burners go off. Blower runs for about a minute, then at the exact same time ...
...carrier furnace code 12 rw closed. how do i fix it. Error code 12 is blower on after power up. Meaning: after you turn on power to the furnace for aprox. 60-90 seconds the blower will run. The blower ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...Furnace is Carrier forced air, about 18 years old. Technician states ''that is what old furnaces do'', cleaned it, checked plenum for cracks, all OK. Could be a defective thermostat in the plenum. ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...carrier furnace, might be too large for house and existing duct work. Would this cause the blower to stay running; would that affect the limit switch. Model #5955-100-121BO Yes. If the high limit is ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
carrier furnace clicking/rattling i have a carrier furnace, it turns on fine, however after a few minutes it starts making a ''clicking'' sound, kind of soundslike a rattling, the burners remain lit ...
...module is expensive and we do not want to buy one if this is not the problem). it is a Carrier 58MVP080 Furnace hi google carrier error , not sure but it could be pressure switch , but it is on ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
Carrier 58STA furnace code 33, no ignition blower stays on. I have a Carrier 58STA furnace. It's getting a code 33 and never trying to ignite. The blower constantly stays on. It is pushing good air ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...Carrier 58MVP furnace with air conditioning that will work some time but many time it will stop with a fault 41 code. I have removed the cover plate over the air condition coils and verified that ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
Furnace question carrier 58ss080-Bc blower motor? Model 58ss080-Bc. After a heat cycle which seems to run normal , blower continues to run which I know is normal as well. After blower motor finally ...