...need on it but here are the most common wiring on a stat W= heat C=Common (24V) R=Hot (24V) G= Fan RC=Hot (24v for Cooling) RH= Hot (24v for Heat) O= Reversing Valve (Heat Pumps Only) Hope this ...

Ad

Question about Programmable Thermostat Heater

1 Answer

wire in? Thermostat wiring depends on which thermostat you are using. The blue wire is typically used for the 24v common. The red is your 24v power. If you have one transformer you will jump RC and RH

Ad

Question about 67680 Evaporative Cooler Air Conditioner

1 Answer

...common for testing when the blower was not on high. Blower on low just green has 24v. Blower on high green and yellow have 24v. If there was a fifth wire added hopefully it would be a ground wire. ...

Question about CKL24AR24 Air Conditioner

1 Answer

...common causes for that are as follows. 1) a blown fuse. (usually a blade fuse mounted on the board) 2) a broken/loose/disconnected wire. 3) a bad 24V transformer. When the unit loses control voltage ...

Question about CKL24AR24 Air Conditioner

1 Answer

...valves 24 volt solenoid, and return to Common as all 24v circuits must to terminate or complete the circuit. Some parasitic type Termostats need the 24v power to run, some are battery, some are

Question about CKL24AR24 Air Conditioner

1 Answer

...24v? Honeywell R8285D1026 hi welcome to fixya, The"r" on subase is hot all time. The queston is do you have a common. Some t-stats dont have a common spot, The only thing you need is a earth ground. ...

Question about Toner Cartridge For Cnm Ir 6570, Black

1 Answer

...common problem on this models the motor is not turning steps first take out the dev unit and see if it has toner in it if the dev unit is full then check the sub hopper unit and if any one of these ...

Question about Toner Cartridge For Cnm Ir 6570, Black

1 Answer

...2 more wires these are your low 24v side colors can range from red,green, blue, yellow ect. the wires for 24v dont matter about polarity or which one you hook up. one is 24v and the other is

Question about Toner Cartridge For Cnm Ir 6570, Black

1 Answer

t the problem then check for 24V at the unit board from W to common. If you have 24V there the stat isn't the problem. I don't know if your heater is gas or electrical, so there's not much else to say

24v and common with a color of wire for C. And if the t-stat takes batteries that you need to install, you shouldn't need C wired in. C is there so you don't need batteries, if it has a battery option