59.F0 ERROR
The primary transfer-alienation motor has experienced an error.
1. Check to ensure the ITB is installed correctly.
2. Run a sensor test to verify that the primary transfer disengagement roller is functioning. If not replace the sensor (SR17).
3. Run the primary transfer drive test in actuator drive mode. If not functioning replace the ITB (Intermediate transfer belt).