RELIANCE ELECTRIC WATER HEATER Logo
Posted on May 22, 2011

I can not light the pilot on my reliance sta-kleen 502 (30 gallon) waterheater. please help

1 Answer

A

Anonymous

Reliance is Rheem
Replace thermocouple is best start point.
Example Whirlpool manual shows general replacement steps on page 22:
Buy thermocouple at hardware or home center. measure length before going to store.
http://waterheatertimer.org/pdf/Whirlpool-6510397.pdf

Utube videos show how to replace thermocouple

Many things can affect pilot:
Low gas pressure, Water or air or debris in the gas control valve, High-heat event causing ECO to trip requiring new gas control valve, burner and tubes needing clean-out, FV sensor tripped, loose or bad thermocouple.
Manual above shows general steps for doing some of these things, but service technician is probably best choice if thermocouple does not fix problem.

Gas water heaters require periodic maintenance.
If repairs cost more than $330, then buy new gas water heater and install yourself.
Use the old one for a solar collector.
http://waterheatertimer.org/How-to-install-gas-water-heater.html

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My water heater pilot light won't stay lit

I would try cleaning the thermo couple surfaces with some steel wool... Both where the flame contacts the sensor, and the electrical contacts. Even a small increase in voltage may be enough to hold the pilot valve open. Both black, and white soot on the sensor end, can act as an temperature insulator, lowering the output voltage.
As for finding the part numbers for replacement: http://www.reliancewaterheaters.com/media/48391/242117_RPPCR01111-Reliance-Parts-Catalog.pdf
0helpful
1answer

Hot water tank wont heat water, how do you relight or resat, its a reliance self cleaning 808

Reliance Water Heater Literature ' Owner's Manuals ...

www.reliancewaterheaters.com/resources/instruction-manuals
Welcome to the Reliance Water Heaters Owner's Manual and Installation ... 9 40 EKRT - 40 Gallon Tall Self-Cleaning Electric Water Heater - 9 Year Warranty . ..... 10 50 DHPST - 50 Gallon Electric Heat Pump Water Heater - 10 Year Warranty .

How to light the pilot on a Reliance 606 water heater ...

? 3:27
https://www.youtube.com/watch?v=VU2PsFVd2ug
Jul 12, 2011 - Uploaded by kilroywashere123
How to light the pilot on a Reliance 606 water heater ... How to fixwater heater, will not stay lit - sealed combustion no hot water - Duration: ...

Reliance Water Heaters - Consumer Affairs

www.consumeraffairs.com > Homeowners > Bath & Plumbing

Rating: 1.6 - ‎84 votes
I purchased a Reliance 606 water heater in 2010. ... That they don't TELL you there's areset button or that I'm having conspiracy thoughts ... After several attempts, I was able to relight it. ... It's heading to the junk pile and I will purchase a new reliable (NotReliance) ... Checked breaker and changed breaker still no hot water!
1helpful
1answer

Replace thermocouple gas water heater

Thank you for the brand. Approx how old is water heater? 2nd and 3rd digit of serial number are year of manufacture.
For general instructions:
http://waterheatertimer.org/How-to-replace-thermocouple.html

Reliance is AO Smith, and air intake is located on bottom of tank.
Inspect and Clean intake.
Do NOT underestimate need to keep air intake clean because the arrestor screen is fine mesh and once clogged will cause heater to fail. Older models might need full replacement and at least parts.
http://waterheatertimer.org/images/Flame-trap-inspection-325.jpg

Product manual?
These gas water heaters are changing quickly today. The Reliance site shows the 909 but not 805
http://www.reliancewaterheaters.com/lit/om.html
The older designs are different, but instructions shown above will help.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

My reliance sta-kleen 502 gas water heaters' pilot will not lihgt. can some one give me an idea what to do.

Reliance is Rheem
Replace thermocouple is best start point.
Example Whirlpool manual shows general replacement steps on page 22:
Buy thermocouple at hardware or home center. measure length before going to store.
http://waterheatertimer.org/pdf/Whirlpool-6510397.pdf

Utube videos show how to replace thermocouple

Many things can affect pilot:
Low gas pressure, Water or air or debris in the gas control valve, High-heat event causing ECO to trip requiring new gas control valve, burner and tubes needing clean-out, FV sensor tripped, loose or bad thermocouple.
Manual above shows general steps for doing some of these things, but service technician is probably best choice if thermocouple does not fix problem.

Gas water heaters require periodic maintenance.
If repairs cost more than $330, then buy new gas water heater and install yourself.
Use the old one for a solar collector.
http://waterheatertimer.org/How-to-install-gas-water-heater.html

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

Can you tell me how old a Reliance Sta-Kleen 820-PV Water heater is?

Find serial number on side of tank.
I think 2nd 2 digits are year of manufacture.
http://waterheatertimer.org/pdf/WaterHeaterSerialNumberDecoder.pdf

http://waterheatertimer.org/Figure-Volts-Amps-Watts-for-water-heater.html
http://waterheatertimer.org/How-to-troubleshoot-electric-problems-with-water-heater.html
http://waterheatertimer.org/Replace-anode-rod.html
http://waterheatertimer.org/9-ways-to-save-with-water-heater.html

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.
1helpful
1answer

Water heater pilot keeps going out. Relight and may stay lit for a day and then goes out again. Now won't even light at all. Has an igniter button. Also says to clean intake screen every 6 months. Where is...

the intake screen or as is called flame trap is located on the very bottom of the heater underneath. this is very important that you keep this clean or it will keep going out. this is the only way this heater has to get air to the burning chamber.
0helpful
1answer

Atwood gas waterheater with white rodgers gas valve pilot hard to light and not a big enough flame to touch the thermocouple

I think you need to reposition the thermocouple, or adjust the pilot gas pressure by adjusting the pilot screw make sure it is still the recommended gas pressure of the system... please contact a HVAC tech if this things did not work.
16helpful
3answers

Pilot won't stay lit in Reliance 606 gas water heater

The Reliance 606 has an enclosed thermal couple. Before you try taking that assembly apart take a wire brush to the bottom opening directly under the burner. There is a metal filter on the very bottom of the water heater. It could be that the filter has gotten filled with dust or animal hair. It took a serviceman 2 days to figure this out for me. The water heater has to have good airflow through that filter to work well.
Not finding what you are looking for?

575 views

Ask a Question

Usually answered in minutes!

Top Reliance Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a Reliance Water Heater Expert? Answer questions, earn points and help others

Answer questions