Haier HBF05EBSS Commercial Beverage Dispenser Logo
Posted on Mar 24, 2011
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

I have a kegerator. It's not functioning. When plugged in no clicking no sound nothing. Wondering if it's the overload switch or relay.

1 Answer

Dennis Boxerman

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Haier Master 1,306 Answers
  • Posted on Mar 24, 2011
Dennis Boxerman
Haier Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Feb 07, 2009
Answers
1306
Questions
1
Helped
646980
Points
2787

Http://www.haieramerica.com/en/asset/product/1ffd77cfa0
This site has your product manual for your dispenser but it is very vague on trouble shooting the cooling system.
In general, the compressor is controlled by a thermostat that is usually located in the conditioned space. It cycles the compressor on and off based on the sensed temperature and the setting that it is adjusted to.
So, let's talk in general refrigeration terms. Where the compressor is located, is there a fan? If so, is it running? That fan is usually the condenser fan and is wired to come on anytime the compressor is supposed to be running. If the fan is running and the compressor is not, then there is an issue with the compressor. If the fan is not running and the compressor is not running, then there is an issue with either power or the thermostat. If the compressor is running and the fan is not, then there is an issue with the fan.
This is a good starting point. Let me know if I can be of further help.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Kegerator. Is the compressor shot?

It's possible that the compressor in your kegerator is shot and will need to be replaced. However, there are a few other things you can check before determining that the compressor is the issue.
  1. Check the power supply: Make sure the kegerator is properly plugged in and that the outlet has power.
  2. Check the thermostat: Ensure that the thermostat is set to the appropriate temperature. If it is set too high, the compressor will not turn on.
  3. Check the compressor overload protector: The overload protector may have tripped, check to see if it is tripped and reset it if necessary.
  4. Check the compressor's capacitors: They could be damaged and need replacing.
  5. Check the evaporator fan motor: If the evaporator fan motor is not functioning properly, it could cause the compressor not to turn on.
  6. Check the 3 in 1 starter: Make sure the 3 in 1 starter is working properly, it could be defective.
  7. Check the wiring: Make sure all the wiring is properly connected and not loose.
If you have tried all above steps and the problem persists, it may be best to contact a professional or the manufacturer for further assistance. It could be the compressor, but it's better to confirm that before replacing it, as it's a costly repair.
1helpful
1answer

Not starting

ck that you are getting power to it some of them have fuses on them , the switch may be bad
0helpful
1answer

TDD 2 Kegerator clicking and not cooling?

It's extremely rare that the compressor will be any good. Usually replacing the start relay does nothing on these small units. If you know how to use a multi-meter and are any good at wiring the cheapest way to go is to get what is called a 3-in-1 start kit at a HVAC wholesaler. You need to know the model of the compressor and/or the horsepower to get the right one. I would recommend getting a service tech to look it over though. Most likely the compressor is locked up.
0helpful
2answers

My ryobi bst10 table saw stopped working. The switch appears fine. I am wondering if the overload protector could be a problem. The little button seems loose?

I'm having the same problem only mine is bran new and has only been turned in one time when I put it together it worked then now the switch is lose and does not make a clicking sound what is wrong with mine
Aug 22, 2012 • Ryobi Saws
0helpful
1answer

Whirlpool model GC3SHEXNS - was in a flood in my house appx. 20" - light comes on in fridge but nothing else happens when I plug it in - just wondering if it's worth having serviced?

:
Hi!
A relay starts the compressor with a higher voltage and then quickly kicks out
It does a lot of clicking (trying to start over and over again)
If thats what is happening with yours
Its best for a tech to replace The relay but you can do it
Take your model number to your Local Appliance parts store they will have a diagram
showing you how to install the relay. Its called a hard start relay
I use part no ERP410 POWER START RELAY, CAPACITOR AND OVERLOAD all in one. (110 v)

If you still have trouble Go Here:

http://www.applianceaid.com/procedures.html

Thank you for using fixya
Leo Ponder
PLEASE VOTE FOR ME IF THIS WAS HELPFUL
10helpful
1answer

I have a 2 year old Haier kegerator and it seems to have stopped working. I hear a clicking sound which I believe is the compressor going on and off. I have done some research and found that this is a...

Do you have any technical background? There is a simple and sure fix to this but you will need to be able to read a wiring diagram and have basic electrical tools like a wire stripper and electrical tape.
0helpful
1answer

My kegerator recently stopped cooling. When I plug it in the fan starts up and then compressor starts for a second and there is a clicking noise and it turns off. I replaced the relay and start/run...

The overload relay is the likely problem. See if it is burnt looking or if it rattles when you shake it. Or just replace it. It's not expensive. If that's not the problem then it's the compressor.
2helpful
1answer

I'm getting a wierd sound coming from my JBL2088HES refrigerator. It is a buzz like an electric shaver followed by a click. It seems to happen in 3 min intervals. Any Idea what it could be?

Kevin,

It sounds like it could be the compressor overload relay or the compressor itself. Lets hope that it is the overload relay, most compressor replacements are very expensive.

The overload/relay isn't very expensive and replacing it will be cheaper than calling a repair tech to tell you if it is the compressor or the overload/relay.

This is a relatively simple repair, if you look at your compressor you will find two wires connected to a small box ( overload/relay )
To remove the overload first you must remove the metal retainer by unhooking it with a pair of needle nose pliers.
Now remove the overload relay by pulling it away from the compressor.

The relay for your refrigerator has a capacitor connected to it, the capacitor and the relay are sold as one piece part # 67005560.

all that you have to do is remove the old relay with the capacitor from the wires by pulling the plug off and connecting the new overload/relay/capacitor to it, reinstall the relay to the compressor and you are done.

Good Luck
Check us out at www.centuryappliancerepair.com

0helpful
1answer

My bev air bm23 kegerator wont cool. the fan works like it is suppose to inside 24/7. The fan outside works as well. There is a hhhmmm sound and then a click. It thought it was the compressor so i took the...

Yes replacing the relay may fix the problem. You want to replace all the start parts. Overload, relay, and capacitor if one is present. Your unit is probably 1/3 horse power or less. You may be able to install a universal 3N1 starter from Supco, rated at 1/4 -1/3 H.P. If new start gear does not fix the problem you may need a new compressor.
1helpful
2answers

I hear buzzing sound and a click like a switch when the compressure turns on.

Then you will need to get that fixed. Sounds to me that your start relay and start capacitor are not making good start connection and the overload is clicking out. If you don't fix this problem soon the compressor may be damaged. I need to know if your model is the MSD2756G or a different model. Let me know..Sea Breeze
Not finding what you are looking for?

537 views

Ask a Question

Usually answered in minutes!

Top Haier Refrigerators Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

vince

Level 3 Expert

2530 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Haier Refrigerator Expert? Answer questions, earn points and help others