Tip: The max point reward for answering a question is 15.
If you do not have communication by the printer when connected by USB cable to the USB Port on the Computer; you are lacking the updated printer drivers. Go to Brother on line, plug in the DCP 8040 ( the printer mod.) in the support area, and download the current printer drivers. Install the drivers and see if you can now connect properly. You can also use the Windows DEVICES to locate the printer and check for updates.
I supose the keybord of that Brother DCP causes this problem. Turn off the machine and try it again. If it does not work afterwords, the machine needs an new keyboard I am afraid.
try to change the port that your printer used. and then restart you computer..if it still dont worked try to unplug and plug it again...while the computer is ON..
6E Heater temperature does not go up
enough. (Slower temperature rise rate than 2°C/5 sec. is detected.)
To cancel the trouble status follows these steps: STEP1 .Press MENU
*,2,8,6,4 STEP2.The machine beeps for approx.
one second and displays “MAINTENANCE" on the LCD, indicating that it is placed in
the initial stage of the maintenance mode, a mode in which the machine is ready to accept entry
from the keys. STEP3.Now you are inside the
simulation Press 01 to reset the
trouble status. STEP4.To exit the simulation press 99 • Pressing the 9 key twice
in the initial stage of the maintenance mode makes the machine exit from
the maintenance mode, restoring it to the standby state. • Pressing the Stop button
after entering only one digit restores the machine to the initial stage of
the maintenance mode.
If again 6E occurs try to check the halogen lamp or power supply PCB.Contact authorized technician to do this checking.
×