Precor 935 Premium Series Treadmill Logo

Related Topics:

Posted on Dec 19, 2010

Stop key showing on precor 935 screen, unit wont turn on

1 Related Answer

Anonymous

  • 10515 Answers
  • Posted on Nov 14, 2010

SOURCE: I have a 2006 Precor

Hi,

Kindly provide few more details :-

1. If you run it at a lower speed, have you ever noticed an issue with the machine?
2. Is it an intermittent or eveytime you increase the speed to above 5 mph, it would stop?

Let me know,so that we could proceed.

Hope i helped you.

Thanks for using ' Fixya ' and have a nice day!!

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How to change password on precore 9.35 treadmill?

Hello!

According to the manual (included in the link), there is no way to change the password on the Precore 9.35 Treadmill from its default setting.

If you would like to disable the password, follow these steps:
1. At the Precor banner screen, press STOP, SPEED?, SPEED?, ENTER, PROGRAMS very quickly
2. At the SELECT UNITS screen, press ENTER
3. Using the arrow keys, select DISABLED at the PASSWORD prompt
4. Press ENTER to accept these settings

https://www.precor.com/sites/precor.com/files/manuals/48854-103%2520933i_9.35i%2520Lit%2520Kit_1005_EN.pdf
0helpful
1answer

Removing a user I'd password from a precor 935 2005

Procedure 2.3 - Accessing the User Parameter Program
This procedure allows you to change the following settings:

• Set Measurement Units
• Enable/Disable Password
• Set User Name

Procedure

1. Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
2. Press keys STOP,5,6,7,1 sequentially.
3. The display will momentarily read SELECT UNITS
4. The currently selected measurement unit will then be displayed.
5. Use the UP, DOWN arrow keys to toggle between U.S. STANDARD and METRIC.
6. Press the ENTER key to select the currently displayed measurement unit.
7. The display will momentarily read, PASSWORD
8. Use the UP, DOWN arrow keys to select either PASSWORD ENABLED or PASSWORD DISABLED
9. Press the STOP or ENTER key to exit the program.
0helpful
1answer

Can you advise please

reset the machine make this: God bless you
Unplug the treadmill. Locate the console key and place the safety or reset key into the treadmill console. Replace any parts that need replacing, or is large enough to trigger with a pencil eraser or Q-tip. Plug the treadmill plug back into the wall. Use the Q-tip to press the reset button. It may be necessary to hold the reset button down for a few seconds. "CL11" will appear in the display of the treadmill.

    • 3
Press the reset button one more time with the Q-tip. "CL21" should appear on the screen. Press the enter key. The display will change again and show "CL22." Keep pressing the enter key until the numbers cycle through to the number "CL26." Press enter one more time. The letter E should appear on the display screen.
    • 4
Press enter twice more. The letters "SS" should appear on the screen. When this happens, press the start/stop key. Making sure to keep well away from the tread, press enter to start the treadmill. The treadmill will start on its own. The treadmill will stop on its own after a few seconds. When it stops, press the power key two times. Remove the safety key and put in a safe place. Your treadmill is reset.move on to the next step.
    • 2
Locate the reset switch on the underside of the treadmill console. Usually the button
0helpful
1answer

Treadmill precor 932 er05 error

Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05
0helpful
1answer

How do you get into the service menu of a precor 932i treadmill?

Typically on the Precor Treadmills if there are errors on the unit, you can press and hold the stop button for 3-5 seconds and it will go into the error log. Not sure what model you have.
E-2 is not what normally shows up on the screen. Do you mean Error 2 was displayed? From what I have read on Error 2's it could be a upper PCA issue, or possibly a dip in AC input during the power up sequence.
Treadmills require a dedicated line, meaning it is on its own dedicated circuit on your fuse panel/circuit breaker.
What exactly is the treadmill doing? Is it constantly showing Error 2 on the screen? Call up Precor tech support. They will be able to give you advice, and or get you connected with an authorized Precor factory trained technician who will be able to get you back up and running.
0helpful
1answer

How to unlock safety code for precor 9.35 treadmill

Procedure 2.3 - Accessing the User Parameter Program
This procedure allows you to
change the following settings:

• Set Measurement Units
• Enable/Disable Password
• Set User Name

Procedure

1. Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
2. Press keys STOP,5,6,7,1 sequentially.
3. The display will momentarily read SELECT UNITS
4. The currently selected measurement unit will then be displayed.
5. Use the UP, DOWN arrow keys to toggle between U.S. STANDARD and METRIC.
6. Press the ENTER key to select the currently displayed measurement unit.
7. The display will momentarily read, PASSWORD
8. Use the UP, DOWN arrow keys to select either PASSWORD ENABLED or PASSWORD DISABLED
9. Press the STOP or ENTER key to exit the program.
0helpful
1answer

Precor treadmill error L5

Precor Error LS, Speed Sensor Signal Missing Probable Cause 1. Intermittent or open connection of the speed sensor (reed switch) wiring.
2. Reed switch is defective or has intermittent connection.
3. Drive motor brushes are bad.
4. Lower PCA is bad.
Corrective Action
  1. Inspect the speed sensor (reed switch) wiring for damage or poor connection to the lower PCA. Replace damaged wiring or reset connection as necessary.
  2. Using an ohm meter, test the reed switch while rotating the drive pulley. The reed switch will close when the magnet passes in front of it.
  3. Inspect the drive motor brushes and replace if necessary.
  4. Test unit with a known good lower PCA. Replace lower PCA if nec
Precor Error Code LS
0helpful
1answer

I have a precor 935 that is showing error 5 stuck key that wont clear. any ideas

Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05
0helpful
1answer

What is the password the get the precor 3.1 treadmill to work?

Procedure 2.3 - Accessing the User Parameter Program

This procedure allows you to change the following settings:

• Set Measurement Units
• Enable/Disable Password
• Set User Name

Procedure

1. Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
2. Press keys STOP,5,6,7,1 sequentially.
3. The display will momentarily read SELECT UNITS
4. The currently selected measurement unit will then be displayed.
5. Use the UP, DOWN arrow keys to toggle between U.S. STANDARD and METRIC.
6. Press the ENTER key to select the currently displayed measurement unit.
7. The display will momentarily read, PASSWORD
8. Use the UP, DOWN arrow keys to select either PASSWORD ENABLED or PASSWORD DISABLED
9. Press the STOP or ENTER key to exit the program.
0helpful
1answer

We forgot the password on our treadmill. How can we reset the password?

Procedure 2.3 - Accessing the User Parameter Program

This procedure allows you to change the following settings:

• Set Measurement Units
• Enable/Disable Password
• Set User Name

Procedure

1. Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
2. Press keys STOP,5,6,7,1 sequentially.
3. The display will momentarily read SELECT UNITS
4. The currently selected measurement unit will then be displayed.
5. Use the UP, DOWN arrow keys to toggle between U.S. STANDARD and METRIC.
6. Press the ENTER key to select the currently displayed measurement unit.
7. The display will momentarily read, PASSWORD
8. Use the UP, DOWN arrow keys to select either PASSWORD ENABLED or PASSWORD DISABLED
9. Press the STOP or ENTER key to exit the program.
Not finding what you are looking for?

314 views

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

920 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...