Diagram showing timer tabs being pushed in or out to set programs:
http://waterheatertimer.org/Water-heater-recirculation-system.html#Grundfos
Grundfos illustrated installation guide
http://waterheatertimer.org/pdf/Grundfos-L-UP-TL-043-install-photos.pdf
Rotate programming ring clockwise until current time lines up with arrowhead on inner dial.
Current time must be reset after power outage.
Tabs located around programming ring control timer functions.
Each tab represents 15 minutes.
Tabs push in or out using a pen.
Tabs out = grundfos ON
Tabs in = grundfos OFF
Set manual switch to TIMER and timer program operates pump
Set manual switch to ON or OFF to override timer program