Model #919.153231 3 hp...20 gal air compressor runs continuously after building pressure. When new, it would automatically shut off after pressure built up, now it never stops when in use.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
check air tank drain valve located on bottom of tank, if it is not leaking try adjusting air pres regulator (large black knob close to air hose connection.) the knob when turned in will increase the tank air pressure, if knob wont turn check that lock ring on bottom of knob to make sure it is disengaged. also check for air leaks in all lines and connections
you must have wired the new pressure switch incorrectly .when the pressure switch opens it will release the head pressure so your compressor must be running with the pressure switch contacts open should be 4 connections 2 marked motor which is from your compressor and 2 marked line which is your power coming in
Sounds like part #27 is worn. Replace # 24 24 A 24 B and 24. the cylinder may be worn. Perhaps depending on the age and time and labor replace with new comp. maybe Dewalt.
The problem with compressors not building pressure is usually a bad pressure switch or bad regulator. Does the motor shut off at 20psi or does it continue running and not build pressure? If the motor continues to run with no increase in pressure, the you should go over the machine looking for air leaks from your regulator back all the way to the motor. Any air leak while the compressor is running can cause the pressure to "peak" way before the intended shutoff that it is regulated to.
Oil free pumps do tend to blow the piston ring (not too expensive) available at searsparts.com. Remove covers to pump and manually turn crank until piston is at top and look at the condition of the cylinder neer top, If it looks scratched, order cylinder kit with piston ring. If it looks good and shiney, could be the valve plate in the head. There are reed valves that tend to break. Run pump however with covers removed and check with soapy water for air leaks and repair as needed (air leaks under the cover will prevent unit from filling). Good luck
Does the motor rotate the compressor or just set there and hum? How old is this unit? Overload heaters may be to small or unit may be single phaseing. Is there air pressure in the tank when this happens.
×