My air conditioner turn off itself and the degrees on the ac would not go pass 31 degrees n its blew no kool air

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Legend:

An expert who has written 200 answers of more than 400 characters.

  • Expert 251 Answers
  • Posted on Jun 07, 2011
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Legend:

An expert who has written 200 answers of more than 400 characters.

Joined: Jun 03, 2011
Answers
251
Questions
0
Helped
76224
Points
272

A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner, the first thing to check is whether the unit is getting proper power. If the unit uses 220 volt power be sure that the proper voltage is getting to the unit. Same for 110 volt units. A voltage meter can be used to assure that the voltage is correct.

For window air conditioning units the voltage can also be checked before and after the thermostat. If voltage is being supplied to the thermostat but not from it then the thermostat probably needs replaced. This is a fairly common problem. Another place to check is the fan motor voltage. The fan on window air conditioners runs both the indoor blower and the condenser fan. If that motor fails than the compressor may run for a short time, but will overheat and shut off. Continued operation like this will result in compressor failure. This motor can be economically replaced for larger window air conditioners, but for smaller ones the cost of replacement will be more than a new unit.

Central air conditioners for the home are more complex and there are more things that can go wrong. As with the window air conditioner the thermostat can also be a problem. The central air conditioner thermostat will only have 24 volts going to it. So don't look for high voltage there. Some units the voltage will be coming from the outdoor unit and others the voltage will be supplied by the indoor air handler or furnace. Most home central air conditioning will be supplied by the indoor air handler or the furnace. If the air conditioner is for cooling only the unit will usually have only two wires going to the condenser unit. Make sure that you have 24 volts across those wires.

The next thing to check will be the indoor blower. If your thermostat is calling for cooling then the indoor blower should be running. If there is no air moving across the indoor cooling coil then you will soon have a big block of ice formed on the coil. This can happen for a few reasons. The indoor blower is not working, the air flow is restricted and not allowing air to move across the coil. A clogged air filter would also do this. Or the outdoor condenser unit has lost the charge of refrigerant.

Finally and worst of all is when you have a complete compressor failure. Often when this happens the compressor will "lock up" or not be able to turn when power is supplied to it. Overheating or lack of lubrication are usually the main causes of compressor failure. Overheating can be caused by the outdoor coil around the compressor getting clogged with dirt, leaves, or grass. Loss of the refrigerant charge will also cause the compressor to overheat. It is the cool return gas coming back to the compressor that helps to keep it from overheating.

As you can see there are many things that can go wrong with an air conditioner and I have not come close to exhausting the possibilities here. I have just touched on the most common problems in a very basic way.
There are some basic trouble shooting things that can be done very easily. Most problems are above out of the range of comfort for many homeowners and professional help should be consulted before any attempt is made at repairs. Remember also, that the release of refrigerant gases into the atmosphere is a federal offense in the
US. Proper care must always be taken to minimize the release of any gases. A license is also required to handle refrigerants. Make sure that the professional you call has the proper certifications to handle refrigerants properly.


http://www.fixya.com/support/r3636709-size_air_conditioner_need

http://www.fixya.com/support/r3623253-window_air_conditioners_clean_every_year

http://www.fixya.com/support/r3633369-portable_air_conditioning_great_portable

http://www.fixya.com/support/r3623166-heating_air_conditioning_scams

http://www.fixya.com/support/r3597468-you_can_add_air_conditioning_to_your_hot

http://www.fixya.com/support/r3583697-how_to_keep_house_cool_without_using_air

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I need a master control knob. I don't know the model number of the Emerson Quiet Kool air conditioner.

Without the Model Number, it's hard to know what knob fits your model. However, the link below, may provide some help. But, having the Model Number would be a bulls eye. Remove the front of the AC unit. There may be a manufacturer's data plate inside, which would provide the model number.

http://www.appliancefactoryparts.com/airconditioners/emerson/emerson-knobs.html

Hope this helps you.
0helpful
1answer

We need one purhcase emerson window ac. Plant send contact details. In noida & New delhi

R.S.AIRCONDITIONER.

Mr Surender +(91)-9818551447 Shop No-5,Sharma Mkt,, Nr B Blk,Mother Dairy,Sec-31, Noida, Noida - 201301

HELPFUL?
0helpful
1answer

Emerson quiet kool model.eqk 1350 f serialo 20e 808320 wont heat, does it have an element? where is it located?

I looked up the model number parts
Their does not appear to be a heating element associated with this ac nor a reversing valve so I don't think it has a heat feature. You could mount it backwards and heat an area. That would look weird.


If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

0helpful
1answer

Air conditioner turned itself on to 22 degrees.

If it got to 22 degrees the Ac unit should have self destructed. What brand and model is that unit?
I think I would love to have one here in Georgia.
2helpful
1answer

BTU's on Emerson Quiet Kool A/C

AC Type dtrquestion.gif Thru-Wall/Window Cooling Capacity dtrquestion.gif 10000 BTU/hr Energy Efficiency Rating dtrquestion.gif 9 EER Fan Speeds (Cooling) 3
1helpful
1answer

Ac has a loud hard bang when compresser kicks in

The internal motor mounts for the compressor are broken, that is the loud banging.
At 17, new one is more energy efficent.
0helpful
1answer

Thermostat window ac turns unit on and off 8 degrees above se

the unit may be drawing the cool air it just released back into itself,plus the air close to the unit may be a little cooler than the air in the rest of the room.
0helpful
1answer

Emerson Quiet Kool A/C Filter

If you know where to find a filter for a Emerson Quiet Kool--Model # 18DD4H-EE
Serial # 21A 927552 Please let me know
[email protected]
Thanks
Ed Beverley
Not finding what you are looking for?

601 views

Ask a Question

Usually answered in minutes!

Top Maytag Heating & Cooling Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Steve Pack
Steve Pack

Level 3 Expert

7128 Answers

ADMIN Eric
ADMIN Eric

Level 3 Expert

39387 Answers

Are you a Maytag Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...