SOURCE: i have a hobart ironman 210 that lost all power
take side panel off where power goes into unit,check for voltage ,if not go to where plug is plugged into check for power if there is power check the crows foot to make sure all three wires are tightly screwed to terminals
SOURCE: Weld arc not stable. Wire feeds, good ground,
Arc blow could be the cause! Put your ground on the work piece and weld away from it. If you weld toward a ground clamp the magnetic forces will blow your arc around sometime. When taking a cert this simple mistake can make or break ya on your cap or reinforcement beads.
SOURCE: will not arc
Check ground connection at welder along with your ground clamp. Bad connection could be the issue. Also check settings on your welder.