Bad capacitor on the inside of the unit.
usually the 10000uf 16v tall cap blue or black cap.
look for a bulge on the top.
replace it with a higher voltage cap.
U have a burned power supply unit. axis 9 comes with 2 mains power options. 110V and 220V. did u select the option correctly as per ur mains supply. europe and asia it is usually 220V and in america 110V. anyway once burnt u have to get it fixed.
Testimonial: "Thanks for the quick feedback. It was on 110 but at least I know it's not a quick fix. Thanks again"