JVM1650SH01 Will cook for 3 to 7 seconds and then shut off. took it to repair shop, they ran many cook cycles and could not get it to fail. Took it home, ran about 10 times perfectly, and then remounted above oven, original problem immediately. Checked elect ckt and even rewired circuit so I know power at receptacle is good. Any answers? Thanx

  • Anonymous Dec 17, 2008

    display goes blank.then comes back on instantly.may work a couple times and then out again.

  • Anonymous Feb 22, 2009

    Mine cooks for about 3 seconds, then shuts off. It is steadily getting worse. I used to put in the time and date and after 5 or so tries it would work. Today, it will not work at all. Also, it doesn't cook right any more. I had to press the popcorn button 3 times last night and it still did not come close to cooking all the kernels. The last several times I made potatoes, they didn't fully cook. In the past week, I have read many, many bad reviews about GE microwaves. Their customer service is lousy, too. I paid a lot of money for what I thought was a quality product. I will never buy GE again. 

×

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Master 770 Answers
  • Posted on Jan 24, 2008
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Dec 03, 2007
Answers
770
Questions
1
Helped
474851
Points
1794

Your problem most likely is in your door aligment there are 2 arms that need to close some door interlock switches inside the unit next time press in on the door hold it and try to start or push down on the door after it is closed and try to start it

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Ge space maker Ge model jvm1650sh01.  Serial hg

It may be a defective upper or lower door switch (or either switch's mount may be bad) or a stuck relay on the control circuit board.

At our Web site, we have a video available showing how to remove a typical over the range control panel assembly in under 5 minutes.

Our file on door switches is here.

After you or a friend look that over, if you still have a problem, we repair these control boards for $39.95 with a one-year guarantee.

Instead of having yours repaired, you can buy a new control circuit board from the Pros here, our favorite supplier.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
0helpful
1answer

I have a Panasonic microwave convection that runs for 2 or 3 seconds, then cuts off. It doesn't matter what setting or length of time you program into it, it will run a couple of seconds and shut down. Is...

See if this describes what's happening:
  • Put in time, push start and unit runs for 2 seconds, relay clicks, unit goes off. Cook time on display goes off and clock time comes back. Bad upper interlock switch and charred connector
If so, see http://207.234.249.73/mwd/safety.txt , http://207.234.249.73/mwd/disassembly.txt and http://207.234.249.73/mwd/doorsw.txt

Otherwise, if the digital programmer circuit / controller does not get a feedback signal from the inverter for a period of 3 seconds, the controller will stop the cook cycle.

That may be a loose connection in the wiring between the inverter, magnetron, and/or control board, or maybe one of those components has failed.


Due to the lethal voltages used and produced in inverters, I do not recommend that an inexperienced person work on these.

You can find an authorized Panasonic servicer here.

In Canada, you can find an authorized Panasonic servicer here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
1helpful
1answer

Ge spacemaker jvm1650sh01 starts to microwave then loses power

See this FixYa solution.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
1helpful
2answers

Shuts off after approx 5 - 7 sec. some smoke

If it stops after 7 seconds, it has a problem with the inverter.

If the digital programmer circuit / controller does not get a feedback signal from the inverter for a period of 3 seconds, the controller will stop the cook cycle.

It may be a loose connection in the wiring between the inverter, magnetron, and/or control board, or maybe one of those components has failed.

Due to the lethal voltages used and produced in inverters, I do not recommend that an inexperienced person work on these.

You can find an authorized Panasonic servicer here.

In Canada, you can find an authorized Panasonic servicer here.
If you prefer to replace the inverter yourself, you can find links to helpful exploded view diagrams and part ordering help here.

I recommend that you bookmark that link to your favorites.We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
0helpful
1answer

Sharp Carousel Model R-1440 won't shut off

Take it immediately to a local Microwave repair shop...looks like one of the circuits may have gone...otherwise switch off from mains
0helpful
1answer

Microwave runs 3 sec then shuts off.

mtystufquit - We've already discussed this by chat & e-mail, and if and when you need further help, please let me know.

"If the digital programmer circuit / controller does not get a feedback signal from the inverter for a period of 3 seconds, the controller will stop the cook cycle."

ddmdavid - you probably have a bad door switch or door switch mount. Please see these links.

http://www.microwavedisplay.com/safety.txt
http://www.microwavedisplay.com/disassembly.txt
http://www.microwavedisplay.com/doorsw.txt

If you still need help, please create a new post with your brand and model number.
3helpful
1answer

Operates for 3 seconds on microwave then stops

If the digital programmer circuit / controller does not get a feedback signal from the inverter for a period of 3 seconds, the controller will stop the cook cycle.

It could possibly be as simple as a loose connection in that area. The repair shop your friend used may not have been Panasonic-authorized.

Due to the lethal voltages used and produced, I do not recommend that an inexperienced person work on these.

I would recommend that you contact your nearest Panasonic-authorized servicer.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
.
0helpful
3answers

Model # NN-T793/T993

My first guess would be to checvk the venealation fan
1helpful
3answers

Microwave shuts off after 2-5seconds

The problem is most likely the magtube, it takes aprox 3 sec for the tube to energize and then it kills the microwave. If you drop the control panel away and start the microwave 90% of the time it will cook fine.
2helpful
1answer

Microwave runs for 3 seconds and shuts off

This is an inverter-driven model, and this is one way the inverter fails. Often it will tick, too, but the cooling fan may be too loud to hear ticking. If you haven't had smoke, then it may not yet catastrophic. I would bet that a thorough resoldering would take care of it. A good technician can troubleshoot and repair this, as needed, but often they will just replace the inverter. Sometimes that's actually cheaper. Troubleshooting an inverter is way too much for someone without good solid technical experience. I would call a shop and ask for an estimate to replace the inverter. Good luck.
Not finding what you are looking for?

448 views

Ask a Question

Usually answered in minutes!

Top GE Microwave Ovens Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

NOEL
NOEL

Level 3 Expert

8606 Answers

Are you a GE Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...