TORK Digital Interval Timer Ssa100r-24 Logo
Posted on Nov 05, 2009

I am replacing an old Tork mechanical Light contoller with a new Tork digital light controller.The unit will control an outside pole light but on the same circuit I have manually switch contolled lights on either of my entrance door.The terminals on the new controller differ. Can you help me out? I am having difficulty with the wiring diagram as it applies to my situation.

1 Answer

A

Anonymous

Tork timers are each a bit different depending on voltage and model number.

Each timer has a model number on inside of timer door.

1) Add a comment with model numbers for each timer, and voltage you are working with, and I will post the conversion wiring.

2) Also look up your model number and wiring diagram on following link.
http://waterheatertimer.org/Tork-timers-and-manuals.html

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How do I wire GE# 15351 24hr mechanical timer switch for 110 volt outdoor landscape lights

15351 is 240 Volt timer... requires 240 Volt to run clock motor.
You need a neutral wire to connect 120 Volt lights.

15351 has same wiring as Tork 1104
http://waterheatertimer.org/images/Tork-1104-wired-to-control-120.jpg

http://waterheatertimer.org/Basic-house-wiring.html#basic-wire

Gene

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Intermatic/GE 15071 digital wall timer - Connection Problem

1) GE 15071 (Tork SS20) is single-pole timer, and cannot be wired as 3-way timer
http://waterheatertimer.org/How-to-wire-timers.html
http://waterheatertimer.org/GE-timers-and-manuals.html#15071

2) Check wire nuts are tight
Remove light bulb and spray WD40 into socket. Reinstall light bulb

3) Reset timer using paper clip or tooth pick, then reprogram to see if functionality is restored

4) Move timer to different location and see if it controls different light

5) Buy another 15071 from home depot.
Remove bad timer, take photo of wires, and install new timer same wire-for-wire.
Return bad timer to home depot in new package.
This is GE's extended warranty plan, but do not mention warranty at return desk.

5) Intermatic and GE are fierce rivals in the timer business.
http://waterheatertimer.org/Intermatic-timers-and-manuals.html
Intermatic makes their own products. GE timers are generally made by Tork. Both companies sell timers worldwide.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

I have an Intermatic T103 DPST timer installed now (120v). The clock mechanism has failed. I bought Tork 1103 guts to replace it. The wiring is a bit different. Can u map for me which wires go to which...

T-103 has 120V clock motor with 5 terminals A 1 2 3 4
Tork 1101 has 120V clock motor with 4 terminals L 1 X 2

T103 is DPST and can control one-or-two 120Volt loads, or one-or-two 240Volt loads.
Tork 1101 is SPST can control one 120Volt load

Common ground between these timers one 120 Volt load
Changeover for one 120 Volt load:
White wires T103 terminal A go to Tork terminal X
Black wire T103 terminal 1 goes Tork terminals L and 1 (there is brass connector plate that connects L and 1 - if connector is missing, jumper between L and 1)
Black wire on T103 terminal 2 goes Tork terminal 2

If Load requirement is greater than T1101, Grainger sells T103 clock motor for $16
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search
http://www.grainger.com/Grainger/timer-accessories/timers/electrical/ecatalog/N-8hi

How to wire T103
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103
T1101 wiring manual
http://waterheatertimer.org/pdf/110111021103WIRING.pdf
6helpful
1answer

I have a Tork timer model number 1101 24 hr time switch. Can you tell me how to set it???

Tork 1101 is a 120V mechanical dial-type timer

c79f9b8.jpgTork 1100 series

To set timer, you lift and rotate dial. Line up current time with the word Time located to lower right of dial.

Next, place trippers on dial. Dark trippers are OFF and light-colored trippers are ON

Tork 1101 is 120V timer.
120V Black Hot wire from circuit breaker connects to Pole L
There is a brass bridge that connects Pole L and Pole 1 >> if this is missing, put a jumper wire that connects both Poles
120V White Neural wire from circuit breaker connects to Pole X
White wire going to Load (lights, fan, motor) connects to Pole X
Black wire going to Load connects to Pole 2

Up-vote if this information was helpful. Thanks for the feedback.
1helpful
2answers

Im installing a TORK 1103.. Im hooking this timer up to 4 outlets.. I have a black, a white, a red and a copper wire.. my problem is I have to turn the timer on and off manually.. The clock is not...

Tork 1103 is mechanical timer with 125V 3 watt clock motor
Dial on front face rotates when clock has voltage
Dark and light colored pins connected to dial, and turn timer on and off
There is removable brass bar that connects poles L and 1

You have 4 wires:
Red >>> I'm not sure about this wire, is this Hot wire coming from tandem breaker?
Black >>> this is Hot wire coming from tandem breaker
White >>> this is Neutral wire
Bare ground

Test wires:
Please test Black and Red to bare ground to see if these are both Hot
Test Hots to white to confirm this is Neutral
Solution ASSUMES black and red are both Hot, and white is Neutral

You have 2 problems:
Prob 1) Clock does not rotate dial: so clock is bad -or- clock not wired correctly
Prob 2) You are able to control 4 plugs using manual override, which means load wires are correct
However, you want to wire timer 'without red wire' (which is confusing, since red wires are connected to outlets)

ef19106.jpg
Solution Prob 1:
1) The diagram show the N or Neutral wire is connected to Unmarked pole on timer
2) Black Hot has to be connected to pole L
3) Unmarked pole and pole L must be wired with 120V as shown before dial will rotate
4) If wiring is correct and dial does not rotate, then clock motor is bad
5) If dial rotates, check outer rim of dial to see if you have dark and light pins for on-off functions
6) Notice that all the Neutrals connect on Unmarked pole

Solution Prob2:
Are you saying that the household wiring extends beyond the 4 plugs, so when you turn off the 4 plugs, it also turns off more plugs and switches farther down the line? If so, you need to wire plugs with separate hot wire.
Let me review features on timer which might help:
1) There is removable brass bar between poles L and 1
2) If brass bar is removed, then you need Hot wires on both L and 1... but you can jumper between L and 1 with short black wire
3) If brass bar is there, then one Hot connected to either L or 1 will power both clock and load.
4) Timer is DPST double pole single throw ... so you can control 2 different loads ... one load connects to Unmarked pole and pole X ... another load connects to Unmarked pole and pole 2

If brass bar is removed:
Jumper between poles L and 1 ... so only one Hot wire is used on your timer.

Below shows jumper on poles L & 1: hot to load is on pole 2

743d806.jpg
2helpful
1answer

Hello can i get the instuctions for tork timer model 1191 please?

According to Intermatic conversion chart, Tork 1191 is same as Tork 1101.

Link to 1101 .pdf
Link to Tork manuals

Tork 1101 is dial-type mechanical timer. Dark pins turn OFF. Light pins turn ON.

Clock motor is 120V
Hot black wire from breaker connects to pole L
Neutral white wire from breaker connects to pole X
Removable bridge connects poles L &1 together
If bridge is gone, Hot from breaker must also connect to pole 1
Black wire to Load connects to pole 2
White wire to Load connects to pole X

Timer can control 240V Load if removable bridge between poles L and 1 is taken out.
Timer clock is still 120V: so 120V Hot still connects to pole L and neutral from breaker connect to poles X
240 V circuit has two hot lines: Hot line 1 and Hot line 2
240 volt Hot line 1 from breaker connects to pole 1
240 volt Hot line 1 to load connects to pole 2
240V Hot line 2 goes directly to Load and does not connect to any pole
1helpful
1answer

Hello I have an older T103 Intermatic which controlls outside lights. It is no longer turning on lights and is making an unusual clicking noise. Can it be repaired or should I install a new...

You can replace the clock motor for $16 ...
http://www.grainger.com/Grainger/wwg/search.shtml?searchQuery=Wh40&op=search&Ntt=Wh40&N=0&sst=subset
... but if the mechanical timer mechanism is worn out, then that is not repairable. To check mechanism, lift timer dial and rotate tripper pins out of way, then click manual override on-and-off >> if override works fine, and lights come on then motor is probably the problem.

If you buy a new T103, the insides might snap right into old timer box without needing to replace the box. To remove insides, depress retainer spring located at top, tip out timer, and lift to remove. New timer has 4 tripper pins. Save old tripper pins, and tape them inside box.
0helpful
1answer

Climate contol does not light up.

Unfortunately the bulbs that light up your climate control are not replaceable and in order to get it to light back up again you need to replace the climate control unit.
Not finding what you are looking for?

199 views

Ask a Question

Usually answered in minutes!

Top TORK Hardware & Accessories Experts

Cindy Wells

Level 3 Expert

6688 Answers

vince

Level 3 Expert

2530 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66831 Answers

Are you a TORK Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides