My Avantco keg refrigerator will not cool down and we have set the controls properly any ideas what it could be

1 Answer

Jorgie Navito

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

  • Refrigerators Master 357 Answers
  • Posted on Mar 12, 2020
Jorgie Navito
Refrigerators Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

Joined: Sep 26, 2009
Answers
357
Questions
0
Helped
108956
Points
2245

FREEZER /FRIDGE NOT COOLING:Optimumrefrigerator temperature at or below40° F(4° C). The freezer temperature should be0° F(-18° C). Check temperatures periodically. Appliance thermometers are the best way of knowing these

Checkurcold control thermostat,urthermistorsin both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as perurmodel ),urair flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) Onthermistorscheck for A close circuit and amount of ohms not just an Ohm reading. As perurmodel. Most shouldatleastshow 1200 ohms. Also Check door seals for leakage.
Evaporator coils
Poorcooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets.
If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited.

FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly.

Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air.But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer.


Condenser
Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator.
May also need to check thedefrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engageurdefrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providingurterminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Placeurmeter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Takeurmeter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Nowur1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u knowurtimer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

THE COMPRESSOR:
If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor,relay and or capacitoris overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed.

To checkurcompressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, somelocated next to compressor in a casing.

You wills see 3 prongs coming out of compressor. 1 goes tourstart winding, 1 goes tourrun winding and the center goes tourground.

Placeurmeter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prongagin. Take note of the reading in OHMS. Example 4 ohms

Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total ofurtwo separate test. 9 ohms, if they matchurok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short inurcompressor. It should show infinity

TO REPLACE RELAY AND CAPACITOR WITH A HARDSTART KIT YOU CAN USE

A3 in 1 start kit for compressors sizes 1/4 through 1/3 HP. And a 5 in 1 for higher H.P. (BE SURE TO MATCH WITH UR COMPRESSOR MODEL NUMBER AND TYPE) Thekit includes relay, capacitor, andoverload device, pre-wired. Thekit will replace all 3 electrical components on capillary refrigeration systems. For newer systems with a run capacitor use?proper kit. For smaller horsepower compressors useTJ90RCO810.

The wire set up is as follows the red wire goes to the right side of compressor prong, the white wire to the left side prong, the black wire to the center prong, and the 2 other black wires go to the power and the ground connection


Lastly you should also checkurTHERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required.


1-3 TEMPERATURE CONTROL
As the food in the fridge gets colder, it gives off less heat, and the air inside the fridge will remain colder. A thermostat called aCOLD CONTROLwill cycle the cooling system on and off to keep the temperature inside your fridge within a certain range. You can adjust that range using one of the dials within your fridge.
On most fridges, all the cold air for both the food compartment and the freezer compartment is produced in one evaporator. Since the freezer is so much colder than the food compartment, most of the cold air that is produced circulates to the freezer compartment. Only a small amount is needed in the food compartment to keep it down to the proper temperature. This amount is adjusted by a smallAIR DOORin the duct between the evaporator and the food compartment. The control for this air door is the other of the two dials within your fridge.

If you hear your compressor "short-cycling" (starting and stopping at short intervals) try jumping across the two leads of the cold controlthermostat ( in the fridge compartment)with an alligator jumper.You can also check both for live voltage current and ohms-If there is a greenthirdlead, ignore it for this test; it is the ground wire. If the fridge starts running constantly, the cold control is bad. Replace it.

To test or change the coldcontrol, firstPull the knob off it and remove any plastic cover plateor housing from it.
You will see two wires leading to it. There will also be a thick, stiffCAPILLARY TUBEattached. The capillary tube is the liquid-filled temperature-sensing element of the cold control, and operates in the same manner as a thermometer
The air damper, baffle or diffuser is the device that balances the air flow from the evaporator fan housing. This normally is a mechanically controlled baffle or flapper that controls the amount of cold air entering the fresh food compartment. If the baffle is damaged or the linkage to the control knob is damaged, then you may not have enough cold air entering the fresh food compartment resulting in higher than normal temperatures. This baffle or damper will be located where the cold air enters the fresh food compartment.

My Avantco  keg refrigerator will not cool down an - defrost timer testing defrost timer pins-undefined-undefined-0_1.jpg

3 Related Answers

Anonymous

  • 43501 Answers
  • Posted on Apr 12, 2010

SOURCE: Refrigerator is not cooling properly

Hi,
As the weather is getting warmer for many people their freezer and/or refrigerator do not work right because of a dirty condenser coil...

Check out this tip that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

http://www.fixya.com/support/r4024657-refrigerator_condenser_coil_cleaning

heatman101

Testimonial: "Thanks for the tip. I have cleaned it in the past at the suggestion of another service tech who came out for a "recall" repair in March 2009."

Ad

Anonymous

  • 67 Answers
  • Posted on Apr 17, 2010

SOURCE: Refrigerator and freezer not cooling properly.

most likely the defrost is not working and it is choked up with ice. Turn off and leave doors open for 24 hours to completely defrost. Then try again, if it works well for a few weeks it will need the defrost looked at.

Anonymous

  • 43501 Answers
  • Posted on Jul 12, 2011

SOURCE: LG Refrigerator Model GR-721R

Hi,

Check out these tips...they can help you figure out what is going wrong withyour refrigerator and why it is not cooling

Refrigeratornot Cooling or Fridge not Cooling

How to Defrost Refrigerator DefrostTimer Problem

WaterRunning in refrigerator from Freezer

Refrigeratoror Freezer not Cooling or Getting Cold
heatman101

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My Avantco refrigerator is leakingg water from inside on bottom shelf, what could be the reason,?

Sounds like you have a plugged drain tube. You can look in the back in the compressor compartment and look for a hose about the size of a chapstick. try a turkey baster to push air or water in it , or a small wire to clear the blockage.
Always disconnect power before attempting to repair any electrical appliance
0helpful
4answers
0helpful
1answer

I have a danby kegerator and i just tap the keg and all its doing is spitting air with some foam and i tasted the beer it was completly flat i need help asap!!!

try changing kegs sounds like the tube in the keg is broken the keg has a tube that runs to the bottom of the keg inside and u push air into the keg to push beer thru that tube and into a cool glass and down to ur gulletbut it sounds like u have a defective keg or an empty keg
0helpful
1answer

I can't get my keg beer under 48 degrees, even at

clean all coils and fins and filter ...don't block exhaust with anything (should be no sugar left to ferment)
0helpful
1answer

I have an older beer cooler. the fan costantly runs but the refrigeration part of the beer cooler doesn't keep the keg cold? ? ? It's refrigerate is r12 cooled. Do you think I could just re charge the...

You would need to be a certified refrigeration technician to even buy R-12, since it is a CRC refrigerant. The kegerator probably doesn't have service ports so you would either have to braze a low-side port in or use a piercing valve, and fix wherever the refrigerant leaked out from. Basically, by the time you pay a refrigeration tech to do all this, it isn't worth it and you would be better off buying a new one
1helpful
2answers

Beverage-Air Kegerator Not Staying Cold

It can take a very long time to get a keg of beer down in temperature. The heat transfer from a keg is slow due to the lack of air circulation inside the keg. You should also check your condenser coils, make sure they are clean. Door gasket should also be in good repair. Hope this helps.
0helpful
1answer

Cooler wont cool below 48 degrees.

Keep a thermometer handy. (adjust temperature control knob accordingly)
Periodically monitor temperatures inside your cooler. (adjust as necessary)
Keep the refrigerator door closed as much as possible to avoid temperature fluctuations

The temperature of the refrigerator compartment is
controlled by adjusting/setting the thermostat control
knob, located on the ceiling of the refrigerator
cabinet.
To start the refrigerator, and achieve maximum
cooling quickly;
• Turn the temperature control knob (using a coin
or screwdriver) clockwise to the furthest
(maximum) setting on the darker blue section of
the graduated control dial.
• Allow the refrigerator to run at this setting for 3~4
hours.
• When maximum cooling is achieved, turn back
the temperature control knob setting to the 2:00
o'clock position on the graduated blue control
dial.
• Correct cooling temperature is a key factor to
consider in storing and dispensing draught beer.
• Optimum temperature for serving draught beer is
between 34ºF ~ 38ºF.(1ºC ~ 3ºC)
• To maintain temperatures ranging between
34ºF ~ 38ºF.(1ºC ~ 3ºC) We recommend the
thermostat knob be positioned at the "2:00
o'clock" setting on the graduated blue control dial.
• To turn off the refrigerator, (no cooling) rotate the
control knob to the "0" position.
Not finding what you are looking for?

3,119 views

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...