Hi, I cleaned the air filter on the Hitachi CP- RX60 projector and followed instructions on the resetting of the timer. Using the remote it jumps (in the menu) out of the cancel mode to sub menu and it will not let me high light the reset. There is no reset on the projector itself. How can I clear the air filter message when I start up the projector?
Hiya there, just worked out how to reset the filter timer so for those that need to know here's the solution;
Bring up the menu and go right the way down to "Option" where it shows you the lamp and filter hours.
Next highlight/select the filter timer section and while its on there hold the RESET button on the remote for 5 seconds.. this then pops up with a resert option and hey, 0h again, good as new! :-)
Oh and if you dont have a remote, just hold the right arrow button instead for 5 seconds in place of the reset and follow instructions as above!
Hope this helps.
Regards,
Omar.
Highlight filter time in menu then press RESET button on remote for min 3s to bring up menu. then up arrow to reset.
Hope this helps.
Under Advanced go to filter time.
The filter time is the time counted after the last resetting. It is shown in the OPTION menu as the use time of the air filter. Performing this item resets the time.
Pressing the RESET button on the remote control or the button > on the projector for about 3 seconds displays a dialog to make sure. To perform reset, poing at RESET using the UP ARROW button
Ok, don't know about the CP-s225, but the CP-RX60 (and CP-RS55). I find it easier not using the remote but the Menu button and the cursor keys. 'menu', then work your way down to the 'reset / Filter Time sub option' option in the 'easy menu' and when you get to the Filter Time option press the right cursor key and keep it held in until the reset menu appears (it needs holding in for 5 - 10 seconds before the reset menu will appear. its more or less the same procedure for the lamptime and filter time but i think the lamp time is only accessible through the 'Advanced menu' which again you select via the cursor keys at the bottom of the easy menu. Apologies if this sounds a bit naf, it what i can remember off the top of my head but the key is holding the right cursor key down for longer than one click.... Hope this helps
It helped. I lost the remote, but could also do it with the buttons on the projector itself. The key is to hold for more than 3 sec. thanks!
Depress the RESET button for at least 3 seconds while lamp time is being displayed. The reset menu will appear. After you replace the filter, select RESET on the menu.
I also have the same problem. Last time I just about managed to get it to reset after working on it for ages, this time I canno. Dioes anyone know the answer? [email protected]
SOURCE: Resetting the air filter timer
Hitachi CP- RX60:
Press the RESET button on the remote control or the right-pointing triangle button on the projector for about 3 seconds. Once you see the RESET dialog, use the upward-pointing triangle to RESET. I can't see what you are or are not doing...so please see page 39 of the user's manual (download found below)
Source:
http://www.aboutprojectors.com/Hitachi-CP-RX60-projector.html
Hitachi-CP-S335 :
"The lamp time is the time counted after the last resetting. It is shown in the OPTION menu as the use time of the lamp. Pressing the RESET button on the remote control for about 3 seconds displays a dialog. To reset the lamp time, select the RESET option using the (triangle) button."
Taken from pg 36 of the users manual (download link below)
Source:
http://www.aboutprojectors.com/Hitachi-CP-S335-projector.html
SOURCE: Resetting the air filter timer
If you do not have a remote here is how to reset the filter time. Use the "Menu" bottun to get the "easy menu" to display. Push the down arrow until you get to "Filter Time," then push and hold the RIGHT arrow to reset the filter time. DO NOT try to reset using the "Reset" option on the easy menu, it will not work.
6,017 views
Usually answered in minutes!
same problem
Hi, I cleaned the air filter on the Hitachi CP- s225 projector and followed instructions on the resetting of the timer. Using the remote it jumps (in the menu) out of the cancel mode to sub menu and it will not let me high light the reset. There is a reset on the projector itself but won'reset the projector hour . How can I clear the air filter message when I start up the projector?
I have the same problem! Can anyone help?
I do not have amanual for the projector. Can you describe the steps in resetting the bulb and filter timer? It appears to be working fine, but the temp and lamp lights remain on. I pulled up the menu and found the screen that lists the lamp and filter time. Both state 107 hours. thanks
Same problem....please help.
I cannot believe there is no help... Never buy Hitachi again.
sam problem
×