Shows code of f06 fills w/water and pumpsout motor wont engage
F/06
Drive Motor Tachometer Error
The control is unable to properly detect motor speed and the machine will shut down. If a failure occurs during high-speed spin, the door will be unlocked after 3 minutes.
Flashes f6
702 views
Usually answered in minutes!
I have an F6 promblen and don't know how to check the harness connection where is it and how do I do it
Same issue, note sure if it is the MCO, CCU, or motor...
part repair bingo is not fun
Had the same problem. Just fixed it. The wire harness from the MCU to the drive motor had two bad terminated ends at the motor on the connector. I took the connector apart and re-terminated the wires on the connector. I couldn't have done it without this site!!!
FIXYA!!!! OOOHHH YA!
×