You should ask your supplier who supplied the generator to you. Because different supplier, configuration is different.
If you plan to purchase diesel generator set in future, please viist at https://starlightgenerator.en.made-in-china.com
SOURCE: Allis chalmers b starter problem
Two things come to mind. If the plug base is too deep it could bottom out on the piston, and if the cam/shaft timing is off by a tooth or more it could also cause this problem. Check it out.
SOURCE: Cub cadet 2145 (Onan engine)runs the battery down
One possible problem is the voltage regulator is out. To test this, start the engine and put a d.c. volt meter on the battery, if the voltage readout decreases as the mower runs, replace the regulator
SOURCE: allis chalmers 912 hydro belt diagram
I also have the same tractor but i have what your looking for so my email address is [email protected]
SOURCE: diesel fuel or hydralic oil getting into engine oil pan
In some engines have lube oil connection from the rngine block to fuel pump for fuel pump lubrication,If fuel pump oil seal damaged automatically diesel mixed with oil
2.If hydro gear pump connected with engine timing cover,oil seal for that pump once got damaged the hydralic oil goes into the engine crankcase.