SOURCE: Mitsubishi VS-50607 Won't Turn On
This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems. To activate this turn the unit on let it shutdown then press the input/device and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source.
SOURCE: mitsubishi ws65909
Yes,but first it is necessary to repair the problem = replace
both STK392-570 IC's.............Then use remote to adjust
convergence............."inside the tv" is called servicer menu = adjust after repair is complete.You can expect to replace IC's
every five years or so.......................T.
PS Try to match your problem thread model # to actual model #
ie. VS-5043 does not match WS-65909........T.
SOURCE: 50" MITSUBISHI BIG SCREEN (MODEL#VS-5076,
INITIALIZE THE SYSTEM CONTROL. WITH THE REMOTE CONTROL PRESS "MENU 2, 3, 5, 8, " USE THE ADJUST BUTTON TO SELECT "INITIAL" AND PRESS "ENTER"
SOURCE: vs 4561 weak picture
Good Day, Techwanab;
Look for this to be your problem: CHECK FOR OPEN L2C50 PART #325C146030 ON THE SIGNAL PCB, OR BAD CONNECTIONS AND LEAKY CAPS IN THAT AREA.
Hope this was helpful and not too late.
Good Luck, big IRISH.
SOURCE: Mitsubishi big screen model VS 60601 convergence adjustment
you need new convergence ICs. If you can respond to this same post and verify the model number of your mitsubishi, I wll post the correct ICs that your model needs.