Have trouble programming. When I reset control the doors opens but when I close door, it stops and reverses, then the light blinks 10 times.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 2,524 Answers

Safety sensors are not aligned, or one of the wires to one of the sensors is broken or unattached, or sensor wires to the unit are broken or unattached. door will always open without sensors being correct, but will not close. try pushing and holding wall button and see if door will close, if yes, then it is the sensor wiring or sensors

Posted on Feb 24, 2016

Ad

1 Suggested Answer

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a liftmaster Model 1240. Door will open by remote or wall opener. The door will only close while holding wall opener button down. If i try and close via remote, light starts blinking and door...


The only thing that will cause the main light to flash 10 times and the door to reverse to the open position is a sensor problem. Make sure the light on each sensor is on and not flickering ever so slightly. Make sure they are not moving when the door starts to close. Lights on sensors should not blink. One light should stay on constantly and the other sensors light should go off when you block the sensors.

Jan 22, 2011 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Have a Craftsman 1/2hp garage door opener (HBW0777 year 1994). It won't close and goes back while blinking 8 or 9 times. Transmitting sensor (red light) is blinking 3 times (even i hold the two sensor...


Anytime the main light flashes 10 times and the door reverses to the open position it is a door sensor problem. If the transmitting sensor light is blinking it is bad.

Nov 20, 2010 | Sears Craftsman LiftMaster Chamberlain...

2 Answers

Lift-master 2000SDR remotes will open but not close garage door. Same problem with all clickers and even those programmed into the cars. What could this be and better yet, how do I fix it?


Lift-Master 2000SDR opener. Opener generally works fine from the remotes. However, first time in the morning in cooler weather, it will start to close and the reverse and the lights blink. I have checked the senors - appear to be aligned properly. I have lubed the gear and used garage door spray on the rollers and hinges at the proper places. To close the door when this happens, I have to hold the wall button.

Nov 25, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Door opens, when closing stops immediately but there is nothing blocking the safety light and lights are green. I can hold the button and door will close but as soon as i release the button it opens again.


Check your door sensors closely. Sometimes one will be off just a bit and the light will be on but blinking ever so slightly. If the main light flashes 10 times when the door reverses it is definitely a door sensor problem. Nothing else will cause that.

Nov 23, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Door won't stay closed, then opens only partially.


If the main light flashes 10 times when the door reverses it is a door sensor problem. Each sensor has a small light that must be on and not blinking for them to work properly. If one of them is not on tweak them a bit to make sure they are pointed at one another.

The stopping about 1/3 of the way up is either a broken door spring, a main drive gear that is going bad or an adjustment to the 'up force'. The 'up force' control is on the back of the motor unit near where all those white wires go. Increase it a bit. It will sometimes compensate for a gear that is going bad but if this is the case it will start doing the same thing soon.

Oct 19, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Door won't close, blinks 10 times, sensor light yellow


Anytime the main light flashes 10 times and the door reverses to the open position it is a door sensor problem or the wiring to them. Nothing else causes this symptom.

Sep 13, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Door won't close, with out hold down on button.


If the main light flashes 10 times when the door reverses it is a door sensor problem. Make sure they are pointed at one another and the small light on each one is lit and not blinking.

Sep 07, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Craftsman GDO reverses itself when the door reaches the eyes


The only thing that will cause the main light to blink 10 times is a sensor problem. Sometimes the sensors will be misaligned just enough to turn the light on but will not work properly. If you look really close (on your knees) you can see the receiving sensor blinking ever so slightly. Tweak the sensors until the light glows constant.

Jun 26, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

When I push open or close the unit starts but stops the yellow light on rear of unit blinks 4 times then a short pause and blinks 4 times again and continues to do this



# of flashes

1

2

3

4

5

6

Rapid Flashing





Problem

The Protector System wire open or totally misaligned

The Protector System wire shorted or black/white wire reversal

Door Control or Multi-Function control Panel wire shorted

IR sensor slightly misaligned (dim or flashing sensor LED)

Motor overheated/Possible RPM sensor failure -- unplug to reset

Motor circuit failure -- replace RX/LX board

Liftmaster transmitter with the correct format code being received
(opener not necessarily programmed to respond)

Mar 28, 2009 | liftmaster Chamberlain Garage Door Opener...

2 Answers

SEARS/CRAFTSMAN 53628SRT Not Closing properly


sounds like the safety door sensors are at fault,also did you reprogram the remotes by pressing the smart button on the logic board,when the safety sensors are bad the door will reverse to open state.you can pully the rip cord to manualy close the door untill you solve the problem.

Sep 04, 2007 | Sears Craftsman LiftMaster Chamberlain...

Not finding what you are looking for?
Building Materials Logo

Related Topics:

204 people viewed this question

Ask a Question

Usually answered in minutes!

Top Building Materials Experts

Tom Chichester

Level 3 Expert

54859 Answers

Lawrence Oravetz

Level 3 Expert

10543 Answers

ray gallant
ray gallant

Level 3 Expert

65416 Answers

Are you a Building Material Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...