What is the nominal consumption in amps of the comet ka 2500's motor

1 Answer

Claude Kayser

Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

  • Comet Master 9,098 Answers
  • Posted on Aug 03, 2015
Claude Kayser
Comet Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

Joined: Jun 15, 2015
Answers
9098
Questions
0
Helped
5067065
Points
28436

2.9 kw/h up to 4.5 kw/h depending on the model.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

What features does a apex tv gt3215 have?

GENERAL
  • TV typeCRT TV
  • Screen size
    32 in
  • Power Consumption Operational
    150 Watt
  • Timer Functions
    Sleep, wake
  • Video Interface
    Composite, S-Video
  • Manufacturer
    Apex Digital, Inc.
FEATURES
  • TV features
    auto volume adjustment
VIDEO
  • Technology
    CRT
  • Aspect ratio
    4:3
TV TUNER
  • TV tuner presence
    Yes
  • Analog TV tuner
    NTSC
  • Reception System
    NTSC-M
  • Secondary Audio Programme (SAP)
    Yes
  • Secondary Audio Program (SAP)
    Yes
  • Channel Coverage
    VHF:2-13, UHF:14-69, Cable:1-125
  • Stereo Reception System
    MTS
AUDIO
  • Speaker(s)
    2 x main channel speaker - built-in - 5 Watt
  • Output Power / Total
    10 Watt
  • Audio Controls
    sound mode
CONNECTIVITY
  • Video interface
    composite
REMOTE CONTROL
  • Type
    universal remote control
  • Supported Devices
    DVD player
CONVENIENCE
  • Closed Caption Capability
    Yes
  • Parental Channel Lock
    Yes
  • V-Chip Control
    Yes
  • Menu language
    Spanish
MANUFACTURER WARRANTY
  • Service & support
    1 year warranty
POWER
  • Nominal Voltage
    AC 120 V
  • Power consumption operational
    150 Watt
DIMENSIONS & WEIGHT
  • Weight
    156.5 lbs
DIMENSIONS & WEIGHT (SHIPPING)
  • Width
    38.7 in
  • Depth
    29.2 in
  • Height
    30.5 in
  • Width (Shipping)
    38.7 in
GENERAL
  • Manufacturer
    Apex Digital, Inc.
1helpful
1answer

Mw612

The Motor Controller has detected excess current in the motor or electronic
switches. This fault has occurred momentarily.
Primary Source: Wiring.
Action: Check the wiring connections from the Motor Controller to the Stator
and the Rotor Position Sensor.
Secondary Source: Motor.
Action
1) Measure/check the motor harness, connectors and motor for shorts. This can
be done by taking a resistance measurement between phases of the motor
harness at the Motor Control module end. Nominal resistance should be
around 12.2 ohm for Phase 2, 3 & Phase 4. For Phase 5 and 6 Smart Drive
the nominal resistance should be around 32 ohms.
2) Check the Rotor Positional Sensor, Stator brass bridge terminal point and
associated harness for water, mechanical damage or corrosion.
Tertiary Source: Motor Controller module.
Action
If all the above show no signs of fault then replace the Motor Controller module.
Also check for water leaks from the cooling chamber or valves that could possibly
come in contact with the Motor Controller and fix the leak before replacing with new
Motor Controller module.
0helpful
1answer

Need a fan motor for millermatic 135 part#196 063

If You are wanting to avoid the high price of an official replacement, you can use an exhaust fan motor from an inexpensive exhaust fan from a home center- but you will need to locate a 24 volt transformer of about 1 Amp capacity -24 Volt Amps. These are used in furnaces so one pulled from a scrapped furnace will also save some cash.

It is a matter of locating the transformer out of the way, then clipping the wires that go from the control board to the old fan motor, Locations on the PC board of 12 and 13 and making those connections. Then running the primary leads and the new fan leads together to the AC power coming in. On 220, you are only going from one hot to return, so your nominal votlage for fan and transformer remain at 115 volts. Terminals 11 and 15 on the Control board.

Since the original was a nominal 24 volts, using a discrete transformer may leave you with a faster than expected feed rate you cannot slow down significantly. If that happens,either put resistance in series with the transformer output, 1,2 or 4 Ohms will slow it down some, as will changing the speed control potentiometer itself.

Miller used a 2500 Ohm linear taper potentiometer in most cases. Raisng the resistance to 5000 Ohms will also slow down the feed rate and using a 1000 ohm linear taper potentiometer will speed it up as well.
0helpful
1answer

Given 1hp motor how to compute the exact amount of amphere use in circuit breaker

You're not going to be able to do this with just a known Horse Power.

There are 3 elements to the equation, with any two, you can work out the third.

If you want to know how the amperage, you will need to know the voltage and wattage of the motor. I imagine that you already know the voltage (It's going to be 220V or 110 volt)

Watts divided by volts = Amps

Examples:

A 220v 1000 watt motor (1000 divided by 220) will draw 4.55 amps
A 110v 800 watt motor (800 divided by 110) will draw 7.27 amps

Bear in mind that most washing machines have a couple of windings for wash and spin. As an average, the was winding will usually be about 500 watts to spin and about 250 watts to wash. ALSO, bear in mind that if you are using this data for a WASHING MACHINE, then there is a water heating element in there too and that draws about 2Kw (2000 watts)

Dont just take this as read, you DO need to check wattages, but, working on what I have just said, the max consumption on a 220V machine will look like this:

At Spin, with a 500 Watt consumption: (500/220) = 2.3 amps
While Washing with a 250 watt consumption: (250/220) = 1.14 amps

Consider that the WASH and HEAT may be running at the same time.
2Kw heating (2000/220) = 9.1 amps PLUS 1.14 amps for the motor - Total wattage 10.24 amps

Watts / Volts = Amps
Amps x Volts = Watts
Watts divided by amps = Volts
0helpful
1answer

How durable is the comet pumps ?

From my experience they are very durable! I have two pressure washers, and two sump pumps that I have built using these pumps and they hold up to hard use.

The sump pumps are used for draining flooded basement and also new foundation pours flooding. So they have had some hard use. I am in the process of building a sump pump for my daughters swimming pool using their pump also.

One CON - make sure you COMPLETELY drain them in freezing weather AND blow air through them to completely dry them.
0helpful
1answer

Excessive oil consumption. Some smoking when accelerating. No visiable external leaks. Any Idea? 1995 GMC Sierra 2500 5.7 L

excessive oil consumption and smoking is usually due to worn rings and/or valve guides in the engine. If you observe blue smoke coming out of the tailpipe, it signals a worn out engine.

If no external leaks, that's what it is. Maybe try to change the oil with a high mileage oil when changing the oil and filter.

I'm afraid, that these conditions don't get better with time.

A replacement motor, or overhaul of the present one is recommended if you cannot pass emissions tests in your area if required by law.
0helpful
1answer

1400 miles/1.5 gal oil consumption

Sounds like you have worn rings in your motor. Needs a rebuild, or replacement.
2helpful
1answer

2001 dodge 2500 4x4 high oil consumption

These are know for having a leaking gasket on the bottom of the intake that will cause oil consumption. To test for this take the pcv valve out of the passenger side valve cover and the crankcase filter out of the driver side. With the engine running put your thumbs over the holes in both valve covers. It should build pressure. If you feel it pulling a vacuum, the gasket is leaking. You have to remove the intake and flip it over on a bench to change the pan gasket on the bottom.
0helpful
1answer
Not finding what you are looking for?

132 views

Ask a Question

Usually answered in minutes!

Top Comet Garden Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Steve Pack
Steve Pack

Level 3 Expert

7128 Answers

Are you a Comet Garden Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...