SOURCE: JVC gr dvl 500U E04...safe gaurd mode/ remove and
Poor contact of drum motor connection(flexi found at the upper part of the drum assy). Solution, disconnect this wire from the connector and cut 1mm from the end so that it will make a new contact. WIre will be shortened a little bit but it still can work this way since this flexi can not be ordered alone, it comes complete with the whole drum assy. Good Luck