How do i fix card obstacle error on Panasonic tde 200

IP 16 extension card

1 Answer

JP Meneide

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Dedicated:

Visited the website for 20 consecutive days.

  • Panasonic Master 483 Answers
  • Posted on Jun 26, 2015
JP Meneide
Panasonic Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Dedicated:

Visited the website for 20 consecutive days.

Joined: Apr 27, 2012
Answers
483
Questions
1
Helped
178139
Points
2858

Hello Fra,
Your tech support would be best to address this issue.
Nonetheless I am including 2 links that can help you.
Best of Luck,
JP
Panasonic KXTDE200 PURE IP PBX Manuals

Panasonic KX TDE200 Manuals

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers

Pc console for panasonic pabx tde 600 e

Google the bolded words below exactly as they are.It should lead you to a download source.

- Panasonic Unified
Maintenance Console UPCMCv7.1.1.7
1helpful
1answer

How can I change line voltage from 24V to 48V in KX-TA308 ?

Why? A TA-308 as well as all Panasonic systems run on 24 volts, even the TDA/TDE. The quickest way to do that, and very expensive, was a Proctor Long Line Adapter (46222/46224). The only time we ever had to use one was to bring up the line voltage of a Merlin Legend extension to interface to a Panasonic system we were using as a factory intercom. The intended purpose is for off-premise extensions as they provide high voltage ringing and protect the system it's attached on.

Proctor is long gone, but Viking Electronics makes an exact replacement. Here are the specs http://www.vikingelectronics.com/products/pdf/lla-4.pdf They also run about $500 for 4 ports.

Carl

0helpful
1answer

I have a panasonic KX-T7130E and want to know how to connect and install it.

It connects to a Panasonic Key Service Unit, pick a number, TA/TES, TAW, KXT, KXTD, and in some cases TDA/TDE/NCP. It's an analog 4-wire system phone, so it requires both voice and data pairs (a 4-pin connection) and a port on the system. You can only connect one 7130 to a system extension.

Carl
2helpful
1answer

I want to change me voice mailbox message on my Panosonic kx-dt321

What happens when you dial 500 on the intercom?

Panasonic has 2 voice mail systems that operate on the TDA/TDE/NCP system. By default, the voice mail extension is 500. If you dial it, the system will answer and you can follow the prompts to record and change the greeting.

If your voice mail is embedded, then you have some oher codes like *382 to play it back and *381 to record a greeting.

Carl
0helpful
1answer

I want to extend the extension numbers beyond134. is it possible with Panasonic KX-TDA 200

Not exactly sure what you're asking, so I'll give you 2 answers. If you mean extension number 134, the answer is yes. The whole universe of numbers are available to you and by default you can use 100-599 in a 3-digit numbering plan. You can grow beyond extension 134 if you have the hardware to support it.

If you're talking about 134 physical extensions, the answer is "maybe" The 200 has 11 card slots. Slot 11 is usually reserved for an option board for a message card and other features. Card slot 1 is usually a digital card for digital extensions, and you need at least one trunk card (slot 10?). That leaves slots 2-9 (8 total) for other cards. Each card is 16 analog or 32 digital extensions, so if the system is being used for single line stations, the answer is 128, but if digital you can expand the memory and address more than 128 extensions. Actually, I think you can address 256 ports before you have to expand the memory.

Carl
0helpful
1answer

Extension Error when setting up new phone

Look in programming, does that extension exist? If not create it. Or, turn on "auto create extension"
0helpful
1answer

Panasonic kx-nt265 npn tunnel, can ping ip

Is the 265 connected via a TDA on the old IP ext card or the newer NCP or TDE if its on the TDE or NCP check the phones software may need to be upgraded, thats the only problem I have ever had with the KX-NT265 I now only use the newer KX-NT321 or NT343,346 etc
2helpful
2answers

No dial tone kx174

That's a trick. Pull out the card on the bottom of the cabinet and see if you get dial tone from the cards in the middle and top positions.

I think A1 and A2 mean extension cards of which you can derive 32 extensions, and the 16 analog ports on the base cabinet. I could tell you about the TDA-100 or 200, so I hope you didn't pay a lot of money for the 174's.

Carl
2helpful
1answer

Change the time on the clock

For the KSU model TDA50, TDA100/200, TDE or NCP.

From the main phone or manager phone default ext. 101 enter prog, *#1234. Then dial program code 000, select enter, Use the up down pad to move the cursor enter your time and date select enter when finished. Then Exit on the screen .
1helpful
3answers

Interconecting 2 Panasonic KX-TDA 200 & KX-TDA600

You are asking for some very advanced setup features, as far as connecting them you need the IPGateway cards. They are cat5 cards that will do the trick. However programming the setup to do what you want will be VERY time consuming and not to easy to walk someone through. On-site tech is highly recommended for that much programming and work.
Not finding what you are looking for?

2,712 views

Ask a Question

Usually answered in minutes!

Top Panasonic Cell Phones Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66977 Answers

Are you a Panasonic Cell Phone Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...