Tania Greenwood Posted on Dec 10, 2014

Hi I have a panasonic split air conditioner. It turns itself off immediately after turning on, the timer button then flashes and that's all.... I have checked for an error code it is H00. I have also made sure both timers are set to 0.00. Can you please advise a fix?? The unit is only a year old...

1 Answer

David

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that hasĀ over 10 points.

  • Contributor 5 Answers
  • Posted on Dec 10, 2014
David
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that hasĀ over 10 points.

Joined: Oct 25, 2012
Answers
5
Questions
0
Helped
5093
Points
10

Hi Tania,
Have you gone through this checking sequence.? it's from a Panasonic a/c manual. It could be something as simple as a clogged filter. Once you have rectified the fault, you will probably have to clear the fault code as described at bottom below, before it will condescend to work again.
David

  • Once error occurred during operation, the unit will stop its operation, and Timer LED blinks.
  • Although Timer LED goes off when power supply is turned off, if the unit is operated under a breakdown condition, the LED will ON again.
  • In operation after breakdown repair, the Timer LED will not blink. The last error code (abnormality) will be stored
    in IC memory.
14.2.2 To Make a Diagnosis

  1. 1 Timer LED starts to blink and the unit automatically stops the operation.
  2. 2 Press the CHECK button on the remote control continuously for 5 seconds.
  3. 3 "- -" will be displayed on the remote control display.
    Note: Display only for "- -" (No signal transmission, no receiving sound and no Power LED blinking)
  4. 4 Press the TIMER ? or ? button on the remote control. The code "H00" (no abnormality) will be displayed and signal will be transmit to the main unit.
  5. 5 Each press of the button (? or ?) will increase error code number and transmit error code signal to the main unit.
  6. 6 When the latest abnormality code on the main unit and code
    transmitted from the remote control are matched, Power LED will
    light up for 30 seconds and a "beep" sound (continuously for 4
    seconds) will be heard. If no codes are matched, Power LED will light up for 0.5 seconds and no sound will be heard.
  7. 7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5 seconds or operating the unit for 30 seconds.
  8. 8 The LED will be off if the unit is turned off or the RESET button on the main unit is pressed.
14.2.3 To Display Memorized Error Code (Protective Operation)
  1. 1 Turn power on.
  2. 2 Press the CHECK button on the remote control
  3. 3 "- -" will be displayed on the remote control display. Note: Display only for "- -" (No signal transmission, no receiving sound and no Power LED blinking)
  4. 4 Press the TIMER ? or ? button on the remote control. The code "H00" (no abnormality) will be displayed
    and signal will be transmit to the main unit.
  5. 5 Each press of the button (? or ?) will increase error code number and transmit error code signal to the main
    unit.
  6. 6 When the latest abnormality code on the main unit and code transmitted from the remote control are matched,
    Power LED will light up for 30 seconds and a "beep" sound (continuously for 4 seconds) will be heard. If no
    codes are matched, Power LED will light up for 0.5 seconds and no sound will be heard.
  7. 7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5
    seconds or operating the unit for 30 seconds.
  8. 8 The same diagnosis can be repeated by turning power on again.
14.2.4 To Clear Memorized Error Code after Repair (Protective Operation)

  1. 1 Turn power on (in standby condition).
  2. 2 Press the AUTO button for 5 seconds (a "beep" sound is heard) on the main unit to operate the unit at Forced Cooling Operation Mode.
  3. 3 Press the CHECK button on the remote control for about 1 second with a pointed object to transmit signal to
    main unit. A "beep" sound is heard, and the Error Code is cleared

  • David Dec 10, 2014


    Hi Tania,

    Have you gone through this checking sequence.? it's from a Panasonic a/c manual. It could be something as simple as a clogged filter. Once you have rectified the fault, you will probably have to clear the fault code as described at bottom below, before it will condescend to work again.

    David


        Once error occurred during operation, the unit will stop its operation, and Timer LED blinks.

        Although Timer LED goes off when power supply is turned off, if the unit is operated under a breakdown condition, the LED will ON again.

        In operation after breakdown repair, the Timer LED will not blink. The last error code (abnormality) will be stored

        in IC memory.


    14.2.2 To Make a Diagnosis




        1 Timer LED starts to blink and the unit automatically stops the operation.

        2 Press the CHECK button on the remote control continuously for 5 seconds.

        3 "- -" will be displayed on the remote control display.

        Note: Display only for "- -" (No signal transmission, no receiving sound and no Power LED blinking)

        4 Press the TIMER ? or ? button on the remote control. The code "H00" (no abnormality) will be displayed and signal will be transmit to the main unit.

        5 Each press of the button (? or ?) will increase error code number and transmit error code signal to the main unit.

        6 When the latest abnormality code on the main unit and code

        transmitted from the remote control are matched, Power LED will

        light up for 30 seconds and a "beep" sound (continuously for 4

        seconds) will be heard. If no codes are matched, Power LED will light up for 0.5 seconds and no sound will be heard.

        7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5 seconds or operating the unit for 30 seconds.

        8 The LED will be off if the unit is turned off or the RESET button on the main unit is pressed.


    14.2.3 To Display Memorized Error Code (Protective Operation)


        1 Turn power on.

        2 Press the CHECK button on the remote control

        3 "- -" will be displayed on the remote control display. Note: Display only for "- -" (No signal transmission, no receiving sound and no Power LED blinking)

        4 Press the TIMER ? or ? button on the remote control. The code "H00" (no abnormality) will be displayed

        and signal will be transmit to the main unit.

        5 Each press of the button (? or ?) will increase error code number and transmit error code signal to the main

        unit.

        6 When the latest abnormality code on the main unit and code transmitted from the remote control are matched,

        Power LED will light up for 30 seconds and a "beep" sound (continuously for 4 seconds) will be heard. If no

        codes are matched, Power LED will light up for 0.5 seconds and no sound will be heard.

        7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5

        seconds or operating the unit for 30 seconds.

        8 The same diagnosis can be repeated by turning power on again.


    14.2.4 To Clear Memorized Error Code after Repair (Protective Operation)




        1 Turn power on (in standby condition).

        2 Press the AUTO button for 5 seconds (a "beep" sound is heard) on the main unit to operate the unit at Forced Cooling Operation Mode.

        3 Press the CHECK button on the remote control for about 1 second with a pointed object to transmit signal to

        main unit. A "beep" sound is heard, and the Error Code is cleared


×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My Panasonic air conditioner model is A75C3012 when i turn it on it start 2or 3 minutes after that the timer light is blinking it turn off by itself. how can I fix this? Thank in advance

Hi,
Try this and see if it works:
- check the remote and set the timer ioff;
- while is turned on, unplug the unit for 5 mins.
Hope it helps.
Regards,
Dan
0helpful
1answer

Hi, I have a Panasonic split A C, i think the off timer is set in it by mistake but when i 'm trying to cancel the timer ..it is not getting cancellrd. All the time timer light is blinking. Pls...

A fairly quick solution is to turn the unit OFF & unplug it for 15 - 20 minutes. Once the time has elapsed, plug the unit back in & turn the ON/OFF Switch to ON. During that time out, the electronics should have reset and reverted back to the original factory settings. You should now be able to set the controls as you like.

Hope this helps and thanks for Choosing FixYa.
0helpful
1answer

Hi, Our Panasonic split system is not working....the timer button just flashes. In the manual it says to hold down the check button for 5 seconds, then hold down numbers 1 and 2 until it beeps to get an...

Diagnosis display = H00
Abnormality / Protection control = No abnormality detected
Abnormality Judgment = Nothing
Emergency operation = Normal operation.

Your unit is under timer set up. Please keep remote towards indoor sensor press timer on and change to 00.00 . If you get beep sound, switch off a/c and then restart.
Not finding what you are looking for?

4,215 views

Ask a Question

Usually answered in minutes!

Top Panasonic Heating & Cooling Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66915 Answers

Are you a Panasonic Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...