The interval of the ROS Start-of-Scan (C) signals exceeds the specified value.
Procedure
+5VDC is measured between the MCU PWB P/J401-A1 (+) and ground (-).
Yes No Unanswered
Replace the MCU PWB ( PL 13.1).
Refer to Figure 1 and check the wire between the SOS PWB (C) P/J514-2 and the MCU PWB P/J401-B9 for an open circuit.
Check the wires between P/J527 and the MCU PWB P/J401 for an open circuit.
If no problems are found, replace the ROS Assembly ( PL 3.1).
If the problem continues, replace the MCU PWB ( PL 13.1).
Figure 1 6-382 RAP Circuit Diagram - ROS SOS C
×