Optoma ES520 DLP Projector Logo

Related Topics:

A
Anonymous Posted on Jul 07, 2014

How to slove this error

Lamp is ok,but lamp led red how to slove

1 Answer

color wheel light tunnel DMD chips retailer

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

  • Expert 138 Answers
  • Posted on Dec 18, 2014
color wheel light tunnel DMD chips retailer
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

Joined: Nov 23, 2010
Answers
138
Questions
1
Helped
94510
Points
190

Please inspect the lamp driver or power supply

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Hp 8000 Solid Red light

desktop small form factor, SFF, (not silly fat frog)
no statement as to where lamp is, I'll guess, FRONT.
just the light bothers you, only..?
why not RTM read the manual to learn what it means.?
so where is said LED lamp, ? front of case on the SSF case?
HP calls it, and searches only work with this.
HP Compaq 8000 Elite Small Form Factor PC./
im reading your manual now for you at HP.com
my guess is lamp 5, (pwr) is not green now but is red
green means power ok, red means, not ok.,
page 2:
if flashing , the flashes are codes, what is your flash code if flashing
if not this LED then say which one?
green on 5 means ok. power ok, no errors. red bad.



sff-s5z5x1uvxsiidstn2afwkml2-3-0.jpg http://h10032.www1.hp.com/ctg/Manual/c01957825


the flash codes are here. page 47 ,

http://h10032.www1.hp.com/ctg/Manual/c01960471

you stumped me, the service manual shows no steady red.
why not ask at Hp.com

more manuals here
https://support.hp.com/us-en/product/hp-compaq-8000-elite-small-form-factor-pc/4065894/manuals


hp forum here.
http://h30434.www3.hp.com/
0helpful
1answer

My 73" mitsubishi dlp WD-73827 turns off and has a red status light blinking. I have replaced the bulb and the heat sensor... any answer to what else could be the problem?

It is helpful to have the sequence of the blinking red light. This may help:

MODELS: WD-52627 / 52628 / 62627 / 62628 / 62827 / 62927 / 73727 / 73827 / 73927

Page 43

3. Error Code Operational Check

Note: The TV must be in "Shut Down" and not have been switched Off, to perform the Error Code Operational

Check. When the TV is switched Off, the code automatically resets to "12" No Error.



Pressing the front panel "DEVICE" and "MENU" buttons at the same time, and holding for 5 seconds,

activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem

has occured since the last Initalization.



Note: The front panel buttons must be used, NOT those on the Remote Control.



• The number of flashes indicates the value of the MSD (tens digit) of the Error Code.

• The flashing then pauses for approximately 1/2 second.

• The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.

• The Error Code is repeated a total of 5 times.



Example: If the Error Code is "23", the LED will flash two times, pause, and then flash three times.



4. Error Codes

The Error Code designations indicating malfunction, or no malfunction, are listed below:

POWER

LED

STATUS

LED

LAMP

LED

Power

Status Condition

Off Yellow Off Low

Power Excess heat. Check Lamp Filter

Off or On Off Yellow No

change

120w usage time over 7000 Hrs.

150W usage time over 3500 Hrs.

Off Off Blinks

Yellow

Low

Power Lamp Cover open

Off Blinks

Yellow Off " Filter Cover Open

Off Off Red Stby Lamp did not turn On

Off Blinks

Red Off Low

Power Fan Stopped

Off Red Off " Circuit failure (short or DVI

connector unplugged)

Abnormal LED Indications

Error Codes "DEVICE" & "MENU"



Error Codes Description



12 No error detected

22 Recovery from Reset

32 Lamp cover is Open

34 Lamp abnormality

35 DM Fan failed (Chassis Fan)

36 Exhaust or Lamp Ballast Fan failed

37 DMD Engine Fan failed

38 Lamp temperature abnormally high. Remove Lamp to check filter.

39 DMD temperature abnormally high

41 Short is detected (Standby Power Supplies)

42 Lamp Fan failed

44 DVI cable between Format and Engine disconnected

46 DMD Temp. Sensor not detected (check DT connector))

47 DM Temperature too high

48 Engine power supply short detected

51 Speaker Drive circuit short detected

52 HDD excess temperature (V30+ & V31 only)

55 HDD Fan Stopped (V30+ & V31 onlyt)
0helpful
1answer
0helpful
1answer

What is wrong with Acer P7280 projector? The lamp goes out after 10 min. use, and red lamp error led turn on

the lamp must be ok
the ballast may be fault
or the mainboard is fault
Have a nice day!
We supply original projector parts: lamp, bulb, Lcd panel, Lens, DMD chip, color wheel,
motherboard, powersupply ... with high quality and competitive price.
Lampdeng Limited
Jerry
0helpful
2answers

Canon ir600 error code E220

sira canon 600 mechan E220 has cmming turn of the power has coming solve the problam how to slove the problam slove it
0helpful
1answer

Tv desn't turn on,power light just flashes ten times and then stops and then again

Error Indication Information
Error No. Error Information ERROR DESCRIPTION LAMP LED OSD LAMP OFF
(Note 3) (Note 4)
POWER LED TEMP LED
Note:
1.When any of the above errors has occurred, the LED will flash as shown above every 5 seconds.
2.When two or more errors have occurred at the same time, the LED will light up or flash as shown above, and then
change to another every 5 seconds in turn.
3.Warning OSD appears when the Air Filter is clogged 90%, accumulated operation time of the Lamp reaches 5000 hours,
or accumulated operation time of the Air Filter reaches 400 hours.
4.LAMP OFF: The LED will flash right after the Lamp goes off.
5.IC2301 is mounted on LCD Main C.B.A. which is included in the Projection Unit.
6.IC6001 is mounted on TV Main C.B.A.
Clogged air filter
more than 90%
15)
16)
17)
18)
1)
2)
3)
4)
5)
6)
7)
11)
8)
9)
10)
12)
13)
14)
- flashes 5 times -
every 5 seconds
IC2301(pin82) detects the clogged air filter, then indicates the
error when the air filter is clogged 90%.
Front Fan stop or
Lamp Fan stop
flashes orange
once every
5 seconds
- -
IC2301(pin12) detects the Front FAN stop or Lamp
FAN stop, then indicates the error when the Front FAN
or Lamp FAN is stopped.
Lamp Cover open
Temperature Sensor
short or open
flashes orange
twice every
5 seconds
flashes orange
3 times every
5 seconds
flashes green for
140 seconds.
flashing red for
60 seconds.
light up red.
flashes once
every 5 seconds
flashes once
every 5 seconds
flashes red for
10 minutes
flashes once
every 5 seconds
-
-
-
-
Abnormal
Temperature
flashes twice
every 5 seconds
flashes twice
every 5 seconds
- -
Request for Lamp
Replacement - - lights up
Power Ballast Error
(abnormal
Lamp voltage)
- -
flashes 3 times
every 5 seconds
Power Ballast Error
(abnormal
temperature)
- -
flashes 4 times
every 5 seconds
Power Ballast Error
(other causes) - -
- -
Request for Filter
Cleaning -
Abnormal Voltage
on 16 V line of
LCD Main C.B.A.
-
flashes twice
every 5 seconds
flashes twice
every 5 seconds
Abnormal Voltage
on 14 V line of
LCD Main C.B.A.
-
flashes 3 times
every 5 seconds
flashes 3 times
every 5 seconds
Abnormal Voltage
on 7 V line of
LCD Main C.B.A.
-
flashes 4 times
every 5 seconds
flashes 4 times
every 5 seconds
IC2301(pin76) detects the Lamp Cover Unit condition
(open or close), then indicates the error when the
Lamp Cover Unit is open.
IC6001(pin85) detects the Duct FAN stop, then
indicates the error when the Duct FAN is stopped.
IC2301(pin74 and 75) detects open or short of the Temperature
Sensor (R2911) on Front Thermistor C.B.A., then indicates the
error when Temperature Sensor is open or shorted.
(The error is not detected for 1 minute after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Front FAN by the Temperature Sensor (R2911) on Front
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 43 C (109 F).
(The error is not detected for 1 minute after Lamp ON.)
IC6001(pin86 and 87) detects open or short of the
Temperature Sensor (R2901) on Lamp Thermistor C.B.A.,
then indicates the error when Temperature Sensor is open or
shorted.
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Lamp by the Temperature Sensor (R2901) on Lamp
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 60 C (140 F).
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin11) detects the error of LCD Power C.B.A.,
then indicates the error when the temperature fuse
(117 C)(243 F) in LCD Power C.B.A. is open.
IC2301(pin11) detects the error of LCD Power C.B.A. and Lamp,
then indicates the error when an inner malfunction of LCD Power
C.B.A. occurs, the Lamp voltage becomes more than 130V or
less than 30V, Lamp current becomes more than 5A, or the Lamp
is cracked.
IC2301(pin11) detects the error of the Lamp, then indicates the
error when the Lamp is short-circuit.
IC2301(pin48) detects +16V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +13V.
IC2301(pin47) detects +14V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +11V.
IC2301(pin45) detects +7V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +5.7V.
IC2301(pin44) detects +3.3V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +2.5V.
flashes 3 times
every 5 seconds
flashes 4 times
every 5 seconds
Abnormal Voltage
on 3.3 V line of
LCD Main C.B.A.
-
-
-
- flashes 5 times
every 5 seconds
Forced cooling
The failure of Lamp
light up
-
Temperature Sensor
short or open
-
-
Abnormal
Temperature
Duct Fan stop -
When accumulated operation time of the the Lamp reaches
5000 hours, OSD (replacing the Lamp) appears on the screen.
Note: The Lamp time is stored in EEPROM (IC2305).
When accumulated operation time of the Air Filter reaches 400
hours, OSD (cleaning the Air Filter) appears on the screen.
Note: The Filter time is stored in EEPROM (IC2305).
During forced cooling, this indication is indicated.
IC2301 (pin11) detects the failure of light up processing of
the Lamp, then the POWER LED is changed as follows.
1) POWER LED flashes green for 140 seconds (while turning on).
2) POWER LED flashes red for 60 seconds (while cooling).
3) POWER LED lights up red (standby).
Note: If the Lamp will not light after attempting turning on the
power 2 or 3 times, the Lamp, the LCD Power C.B.A. or the
LCD Main C.B.A. may be defective.
Error Symptom Problem Possible Solutio
0helpful
1answer

Panasonic projection TV does not turn on.

Power LED flashes orange 1 x 5 secs. = 1 of 3 fans stopped. TEMP LED flashes 1 x 5 secs, = Temperature error. Lamp LED flashes 1 x 5 secs. = lamp ballast error. (check lamp 1st.)
Hope this helps.
0helpful
1answer

Fujitsu Scanpart 620c Leds error Amber on, Green blinking,red bli

Hi,
Thank you for contacting Fixya.
You need to check the blinking times of the Paer jam LED. Then check the followings:
1. If the lamp is on, then ADF Switch is malfunctioning. Disble or short the switch.
2. If the lamp is off, then it is Flatbed or ADF Inverter error. Lamp inverter circuit is to be replaced.
5. If the Lamp is still off, then Lamp is to be replaced.
6. If the issue still persists, then you may have to contact the authorized Avision Service personnel for further diagnosis and suggested repair or replacement.
Hope the above information is helpful.
Please revert if you have any doubt.
Regards,
TechSatya
0helpful
1answer

Kodak DS3500 scanner

Are you using a Kofax SCSI card or an normal SCSI controller like Adaptec?
By using a normal SCSI controller, is there an ASPI driver problem after a WIN XP update? After an update check the ASPI dlls in \sytem32. They should be version 4.71 or higher.

Check the SCSI connector pins and the terminator.
If available change the cable.

Scanner check:
Is the green lamp (Ready) on or is the red lamp (Error) on?

- green lamp on:
the internal self test is ok, but the internal SCSI interface may possibly faulty.

- red lamp on:
the internal selftest detect an error.
It's possible that the DC/DC power board, the CPU board or the power supply inside the scanner is defective.
After reassembling the front side camera you will see at the bottom a PCA board with some LEDs whitch indicate by red light the different voltages when power is on. You find the different voltages printed at the PCA close to the LEDs.
In case on or more LEDs don't shine the according DC/DC transformer on the PCA is defective.
Futher you see LEDs at the camera PCAs. They should be on too.

In case the CPU board has an defect you must have an special Kodak activation tool to unlock an new or used CPU board after exchange.



1helpful
1answer

TV turns off aftering powering up. red LED flashes 3 times.

3 red blinks means th lamp door in not on. if you have installed the lamp door corectly and it still does this solder all three pins together on the door switch.
Not finding what you are looking for?

113 views

Ask a Question

Usually answered in minutes!

Top Optoma Office Equipment & Supplies Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

john h

Level 3 Expert

29494 Answers

Are you an Optoma Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...