Cooktops Logo

Related Topics:

Posted on Nov 07, 2007

Gas cooktop vent code

What is code, for needed distance from a window for venting a gas cook top grill or stove

  • 1 more comment 
  • Anonymous Nov 14, 2008

    I have same problem. Builder telling me I don't need it, but it's hard to imagine not having one. Anyone?

  • Anonymous Dec 31, 2008

    I live in california, and would like to know what is the minimum distance a gas kitchen stove can be from a window.

  • Anonymous Mar 12, 2014

    oven works but cooktop does not

×

1 Answer

A

Anonymous

Planning to install a 30" stovetop natural gas.need to know if i need a vent to the outside, it has 4 burners

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I used my grill for the first time, & the downdraft didn't work we'll, the house filled with smoke & eventually the downdraft shut off and I had to finish cooking in a pan. My Jenn-Air is...

The downdraft is electric so there must be something malfunctioning with it. It is a high volume downdraft fan that is to be vented to the outside. Could it be that something has clogged the vent hole up, not allowing the fan to evacuate the smoke?

While I am not a big fan of Jenn-Air, their fans are usually high quality if they are installed correctly, with the proper vent lines.
1helpful
1answer

The Grill side on my electric cooktop doesnt seem heat up enough

I had the same problem with the 45" Jenn Air downdraft cook top. The installation of the ductwork from the stove to the outside of the house was not properly installed. The stove is appr 18' from an outside wall and the flow of air was hampered by
too great a bend in the ductwork at the point below the stove on the underside of the house and the pipe going to the outside wall. I believe that was corrected with more curve in the vent work, making for a smoother flow of air. Make sense?
0helpful
1answer

My new home already has a hood vent for the range. I have a gas Jenn air downdraft range. I prefer to use the hood vent as the downdraft is not very efficient. Do I have to connect the blower on my range...

The poupose of either is to eliminate any smoke created by the range or grille and move as much of the cooking odors to the outside. I wouldn't use both at the same time, but if the hood is vented to the outside, it would be just fine to use only the hood. Aregular cleaning will be necesssary. The downdraft has limits as to the distance it will efficiently exhaust air. Flex hose should not be used. And excessive bends or vent length, cuts into the efficiency.
0helpful
1answer

What is a bottom vented cooktop

There is a fan that sucks DOWN like a Jenn-Air cook top. There is no hood usually over such a stove. Usually the suction for the vent is between the burners. I think the air can be exhausted through a filter back into the room or to the out of doors.

The salesman didnt explain this to you???

I hpe this answers your question

1helpful
1answer

Want to vent gas cooktop from top of ceiling cabinet down to basement and out chimmney. Distance is approximately 20 feet with four 90 degree angles. Suggestions? Thank you.

There are special fans that are used for this. Use the web to look up exhaust fans. Normally used for boilers, tumble dryers where the distance required to run is further than the fan supplied with the item can push it. The fan will need to be wired in so that the gas cannot be turned on until the fan is running. Pick the fan that best matches flue diameter, temp, and distance
Oct 04, 2009 • Cooktops
2helpful
1answer

Downdraft vent unit is stuck halfway.

You'll have to remove it and manually reverse the drive gear. Hopefully, it didn't get stripped.
3helpful
2answers

One of 4 burners doesn't spark/light -- GE JGP979 Cook Top

I am going to assume you hear the "clicking" sound when you try to light the burner.
open the top of the stove. there are four burner. look at the one that is not lighting. use a straighten paper clip open the holes that is directly in-front of the tube that is facing the center of ignitor.
also make sure that the air vent directly behind the knob is fully open.
0helpful
1answer

Broke glass on electric genn-air

Please do not use the stove if the element is viable because of broken glass, this could become a danger to yourself.

Look at the cost of a new stove, you should be able to get one for
around 400.00. One of my customers had a glass top with 4 burners,
they had the same thing happen, the cost to replace the top was
1,200.00. So I would assume that you can get a new stove with 4
burners less then it would cost to replace the part on a stove you don't like. Maybe there is a LOWES around you to look at stoves,
they seem to be everywhere,like death and taxes.

As for putting a 4 burner top on a stove that has 2 with grill, I don't think it can be done without the extra cost of adding the parts to run the other 2 burners, so like I said in the long run,it just might be cheaper to but a new stove. It should not be a big deal to remove the exhaust from the grill part of the stove.

I looked at the model# you put down,and it does not have a grill,
from what I see, there are 4 burners and a downdraft vent in between the 4 burners, there are 6 models with this part # and none have a grill,only the downdraft vent.

If the model# is right, the cost would be around 300.00 for the glass, and then the cost of having it replaced. So I would say over
400.00, In which case for the same amount you could have a new one, but you must weigh the difference for yourself and see what you think is the best way to go.
If you have any more questions,please post back and everyone is more than willing to help you. I hope I have helped a little.

,.
0helpful
1answer

Thermador Cook 'n' Vent Stove with stuck vent (model # SGCS304RS)

I just had a similar problem. The switch knob, and backer for the blower got jambed in the housing. After pulling it all apart I called the parts center at Thermador and ordered a new switch. If you can hear the motor the raises the unit run, then that could be your problem.
Oct 11, 2008 • Cooktops
0helpful
7answers

Venting codes for a pro style Dacor stove top

what need for the code as long as you it safe for your family.. and accesible for yu its okay..
Mar 03, 2008 • Cooktops
Not finding what you are looking for?

1,562 views

Ask a Question

Usually answered in minutes!

Top Cooktops Experts

Paul Carew

Level 3 Expert

3808 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66949 Answers

Are you a Cooktop Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...