Whirlpool LGR5636L Gas Dryer Logo

Related Topics:

A
Anonymous Posted on Jun 10, 2014

How to replasce gas coil valves on whirlpool mod#wgd5540sq0

How to change gas coil valve?

5 Related Answers

Anonymous

  • 2071 Answers
  • Posted on Jan 28, 2009

SOURCE: Gas Dryer quit heating today

Just click below;

If your dryer doesn't heat, check these:

Igniter
Gas valve coils
Thermal fuse

Hope it may help you;

Regards;
VOTIT

Ad

Anonymous

  • 3 Answers
  • Posted on Feb 27, 2009

SOURCE: I Have a gas dryer, and I changed the coil valves

Test thermal fuse mounted on blower housing

Anonymous

  • 57 Answers
  • Posted on Mar 04, 2009

SOURCE: Whirlpool dryer (no heat)

does the ignitor light up if it does check continuity on the thermo fuse (the little white one) if ok replace coils

BOYNISMO

  • 120 Answers
  • Posted on Aug 21, 2009

SOURCE: How to replace gas coil valves on Whirlpool LGR5636EQ3 Gas Dryer

DOES YOUR DRYER HAVE THE LINT SCREEN ON THE TOP? IF SO, REMOVE THAT AND TAKE TWO SCREWS OF(CARE NOT TO DROP IT INTO THE VENT). PULL THE TOP PANEL TOWARD YOU LITTLE BIT AND LIFT UP, THERE WILL BE TWO 5/16 SCREWS INSIDE FRONT PANEL, REMOVE AND UNPLUG THE LID SWITCH CONNECTOR, FRONT PANEL WILL COME OUT. THE GAS VALVES AND COILS ASSEMBLY WILL BE ON THE BOTTOM RIGHT. UNPLUG AND TAKE THE SCREWS OFF THE BRACKET AND REPLACE COILS. CHECK FOR CONTINUITY ON COILS, IT SHOULD READ 1.3 TO 1.9 OHMS. THE ONE WITH THREE TERMINAL, CHECK OHM FROM MIDDLE TERMINAL TO OUTSIDE TERMINALS.

[email protected] 714-334-1998.

Anonymous

  • 311 Answers
  • Posted on Apr 13, 2010

SOURCE: WGD5540SQ0 whirlpool dryer does not get hot.

if the ignitor is glowing then replace the gas coils they are part number 5303931775. If the ignitor is not glowing then look at the thermal fuse located either on the blower housing or if the lint screen is on the top its behind the back panel. Its skinny and white if its blown replace that and the thermal fuse and check your venting because clogged venting can cause the thermal fuse to blow. There should be a small square access piece at the bottom corner of front panel you can remove to see if the ignitor is glowing or not. Hope this helps _MJ_

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2helpful
1answer
0helpful
1answer

My dryer is not heating up the vents are clean just blows cold the gas is on its a whirlpool model wgd5540sq0

You need to check the thermostats, igniter and gas valve. Here is a link to a video to show you how to do that.
http://www.youtube.com/watch?v=fP9pmbw6PzQ
1helpful
1answer

Whirlpool LX1550 gas dryer. Not heating. Lights once at beginning and then shuts off. Does not liht again.

Remove the front panel to get to the gas valve. (Sorry, without a valid model number can't tell how to do it)
Remove the metal bracket holding gas valve coils.
Replace both gas valve coils, part number 279834.

Good luck,
Vlad
First Choice Appliance
0helpful
1answer

Gas dryer works, I can hear the ignitor start but there is still no heat

Good day,
If you hear a clicking, followed by a delay of about 45 seconds and it repeats this sound, it's usually the coil kit mounted on the gas valve, not opening the gas valve.
It consists of 2 coils that are purchased as a kit.
If your dryer has the lint filter on top, then you can use the link below to get to the valve.
The link is for changing the belt, but the beginning shows how to get to the gas valve, mounted inside the cabinet. It is manufactured by whirlpool.

http://www.wikihow.com/Replace-a-Dryer-Belt-on-Whirlpool-Models
0helpful
1answer

I have a gas Whirlpool dryer. I have changed the

no way to visually inspect that i know,but is the gas valve opening? you may have to replace the magnetic coils tat opens the valves.also tap on the gas valve lightly,could be sticking shut.
Sep 08, 2009 • Dryers
0helpful
1answer

Kenmore gas dryer mod.110-73942. burner comes on as normal. After 5-10 minutes running Cycles off, igniter ( new) glows but no burner ign. Also replaced the sensor adjacent the igniter.

The gas valve coil is bad. When the ignitor is glowing the gas valve should open and allow gas in to be ignited. Change the gas valve.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/craig_3fa289bf857b1a3c

3helpful
1answer

No heat, blowing cold air

Hi, You will need to change the coils. They get weak later in cycle and will not open the valve.
Does the moise accur when the gas ignites in the first part of the dry cycle. It is possible the gas valve is starting to go bad but, it is not very common.
Here is how to change the coils:
UNPLUG the dryer. This model you need to remove the two screws under the lint screen. Now use a flat blade screw drive and insert it in the gap between the top and the front panel and pry the top up. Now locate and remove the screws on the inside of the front panel in upper corners. The front should lift off. You will see the two black coils on the gas valve. When you remove the three wire coil, make sure the sleeve inside it gets put back on the post the coils slides onto.
If I can assist you further, please let me know.

Thanks
Vic
1helpful
1answer

Where is the coil valve located?

The coils on this unit are located on the gas/burner valve Assembly. this is a all in one situation. everything is located on the gas valve assembly. you will need to remove the coils from the gas valve assembly.they are attached to the valve assembly.

Located on the back side of the unit on the lower back side. (right)
0helpful
1answer
1helpful
4answers

Does not heat

There is NO starter on a gas dryer burner assembly. The burner is controlled by gas valve coils and a glow bar igniter. Once the igniter reaches the appropriate current level, the gas valves open and you have ignition. The common problem is a weak igniter. You need to do a current measurement to make sure the igniter is within tolerance. If it is within specs, then I would agree with docjohn174 about replacing the coils. If its not within specs, you need to replace the igniter. Depending on the type of igniter you have, the current rating is as follows:

TWO BASIC IGNITER TYPES:

Carborundum (Cylindrical in shape) – needs to produce 2.5 to 3.0 amps for the gas safety valve to work.
Norton (Rectangular in shape) – needs to produce 3.2 to 3.7 amps for the gas safety valve to work.

NOTE: There is a UNIVERSAL FLAT BAR igniter on the market as well, that can be used as a substitute if the igniter type that came with your range is not available.

I still need an accurate model number in order to confirm WHICH type of igniter you have.
Not finding what you are looking for?

108 views

Ask a Question

Usually answered in minutes!

Top Whirlpool Dryers Experts

Virgil Watts

Level 2 Expert

267 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Whirlpool Dryer Expert? Answer questions, earn points and help others