- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
according to the maker there is no C555t a c55t-1234 (note the vast submodels not stated by you....1233 is m fact sub number what is yours? but is kinda off topic but gee, wrong model stated out of the gate. Ok what update is running, we cant see your screen 1: tell all words on screen and logo's 2: post photo of failing screen
sorry we can not guess WHAT is updating good luck. for sure.
Here are the steps they recommend in the users manual for a c55 error.
5.1.11 Optional communication related service call [C55] ADF I/F error [F11] ADF I/F error (1) Check if the connector CN71 on the ADF/RADF board is disconnected. (2) Check if the relay connector between the ADF/RADF board and the PFC board is disconnected. (3) Check if the connector CN246 on the PFC board is disconnected. (4) Check if the connector pins are disconnected and the harnesses are open circuited. (5) Check if the conductor patterns on the ADF/RADF board and the MAIN board are short circuited or open circuited. (6) Replace the ADF/RADF board. (7) Replace the MAIN board
×