Life Fitness 9100 Next Generation Remanufactured Treadmill Logo

Related Topics:

A
Anonymous Posted on Jan 07, 2014

Display is in maintenance mode - Life Fitness 9100 Next Generation Remanufactured Treadmill

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Brother DC8060 how to reset fuser life

ENTRY INTO THE MAINTENANCE MODE
Press the [Menu] and [Start] keys. Next press the [/\] key four times to make the machine enter the maintenance mode.
FAX models equipped with numerical keypads can enter the maintenance mode by pressing the [Menu], [*], [2], [8], [6] and [4] keys in this sequence.
The machine beeps for approx. one second and displays MAINTENANCE " on the LCD,
indicating that it is placed in the initial stage of the maintenance mode, a mode in which the machine is ready to accept entry from the keys.
To select one of the maintenance-mode functions press the [/\ ] key or [\/ ] key to display any function code on the LCD. Then press the [OK] key 88 Counter Reset After Replacing the Fuser Unit, Laser Unit and
Paper Feed Kit
0helpful
1answer

How to enter maintenance mode KM 3050

Press the STATUS KEY

With the numeric key pad key in 10871087 (if done correctly the display will change and say ENTER MAINTENANCE ITEM)

Enter 201 with the numeric key pad (follow the steps below):
1. Press the start key. 2. Select the [INITIALIZE].
3. Press the start key.
4. Press the center of the + keys. Be sure to press three + keys displayed in order. The touch panel is adjusted automatically.
5. Press the indicated three + keys, and then check the display.
6. Press the stop key. The screen for selecting a maintenance item No. is displayed.
Completion Press the stop key. The screen for selecting a maintenance item No. is displayed.

Now to exit maintenance mode key in 001 with the numeric key pad

Press the Start Key ( you should be back to the status screen, press copy key to go back to the copy mode)

Remember do not go to any other maintenance mode or make any other changes.
0helpful
1answer

T632 reset count

Enter diagnostic mode:



1. Turn the printer off.
2. Press and hold the Go and Return buttons.
3. Turn the printer on.
4. Release the buttons when Performing Self Test displays on the operator panel.

Once you're in diagnostic mode, go to Printer Setup > Page Count.


To reset the maintenance page count to zero:

1. Select Reset Maintenance Count Configuration menu.
2. Pressing Select resets the maintenance page counter to zero.

Reset Maintenance Count Saved displays momentarily. When the reset operation is complete, the menu returns to the Printer Setup Reset Maintenance Count screen.
1helpful
1answer

Printer unable to clean

This most likely means that the over flow tank is full. You can order a replacement tank but you have to disassemble the printer pretty far to get to it. You would also need to reset the counter so ..... if you want you can just reset the counter. Doing this without replacing the Ink Absorber will mean that once it is truly full it will leak into the printer itself. Do so at your own risk, but then again these are cheap printers....

Brother Maintenance Mode Commands:
- Quickly press Menu/Set * 2 8 6 4 to enter maintenance mode.
- Display should read maintenance.
- Press one or more of the maintenance mode commands below. After each command display should read re-init for a few moments then redisplay maintenance.
- Press 99 to exit the maintenance mode.
Maintenance mode commands:
01 Full RAM clear (see 91 below for retaining user programming)
02 scanner initialize (feed a white sheet, then a black sheet)
05 white level
09 print test
10 modify soft switches
11 print configuration list
16 panel test
19 CML test
20 signal test
21 tonal test
23 filter RX
54 scan edge
55 scanner area
66 test print memo
75 display drum life (if enabled on laser models)
76 reset drum life counter (laser models)
91 parameter initialize (user programming remains intact)
95 protection
99 Exit maintenance mode"

I would use the 01 and reset everything. Otherwise you can go through the 91 parameter list till you find the counter.

Jim
7helpful
2answers

Hi, Have a Kyocera KM4050 copier/scanner/printer with a touch screen. The touch screen is out of alignment (i.e. where you point does not align with what is sensed by the touch screen) and needs...

First you have to get into the maintenance mode. It is important once in there you don't make any changes other than the one I tell you or you could damage the machine.

To get into maintenance mode do the following:

Press the STATUS KEY

With the numeric key pad key in 10871087 (if done correctly the display will change and say ENTER MAINTENANCE ITEM)

Enter 201 with the numeric key pad (follow the steps below):

1. Press the start key.

2. Select the [INITIALIZE].

3. Press the start key.

4. Press the center of the + keys. Be sure to press three + keys displayed in order. The touch panel is adjusted automatically.

5. Press the indicated three + keys, and then check the display.

6. Press the stop key. The screen for selecting a maintenance item No. is displayed.

Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.

Now to exit maintenance mode key in 001 with the numeric key pad

Press the Start Key ( you should be back to the status screen, press copy key to go back to the copy mode)

Remember do not go to any other maintenance mode or make any other changes.

28helpful
2answers

I have a Oki b6500. Replaced the fuser. How to reset the message exchange, "Maintenance." Please help!

The following procedure was provided by Oki Tech support when a web search did not provide an answer. Resetting the Fuser After Replacement - When Counter is NOT Reset First print out a MenuMap and note the fuser count, to later verify that the maintenance reset has taken affect. To reset the fuser counter, enter the diagnostics mode and go to Maintenance Mode Step-1 How to enter the maintenance mode. Hold the Menu & Right arrow button while powering on the printer. Hold the buttons down until the op panel displays “Initializing”. The op panel will display “Output Test” Step-2 Press the down arrow three times. The op panel will display “Maintenance Info” Step-3 Press the right arrow. The op panel will display “Reset Maint Reqd Execute” Step-4 Press the select button. A quick flash will come up on the op panel “Resetting Maintenance Reqd”. The op panel will then display “Reset Maint. Reqd. Execute” Step-5 Press the Cancel button to exit the Maintenance Mode and go back to “Online”. This completes the process, please print out the Menu and inspect the Fuser Count it should read ‘0.’
1helpful
1answer

Upper body workout arms on Startrac 6230 crosstrainer are locked in the ''None'' position. How do I switch to ''Pushing'' or ''Pulling''?

You May have to recalibrate Here is the procedure
Engaging Maintenance Mode 1. Press and hold the , and keys together. 2. A beep will sound and the “MAINTENANCE MODE” will display momentarily in the information window. 3. Release all keys. “SERIAL NO XXXXX” will display in the information window.
Modifying the Maintenance Mode The following keys are used to modify Maintenance Settings: Upper and Lower Data Information Window SCROLL keys: Display the next and previous settings. Increase and Decrease Level Keys: Adjust the value of the displayed setting up and down respectively, in increments of 1 unit. OK Key: Updates (saves) the value of the display setting in the Flash

Diagnostics - UB Calibration UB (Upper Body) Calibration (Elite Only) The UB Calibration will set the minimum and maximum range of the upper body arms in which they can move within. You can do a Manual Calibration or an Auto Calibration. Auto Calibration is recommended. To calibrate the Upper Body: 1. Enter the Maintenance Mode (see Settings – Maintenance Mode). 2. Press until UB Calibration is displayed in the information window. 3. Press to enter UB Calibration Mode. Manual Calibration 1. For Manual Calibration press 1. 2. Press the until the upper body arms stop moving (None Position), and then press to save. 3. Press the until the upper body actuator stops, and then press the to save. Auto Calibration For Auto Calibration press 2. The display will automatically raise the arms up, then bring them back down to calibrate the positions.
0helpful
1answer

Switches to "Quick Start" before I enter all information

The Maintenance Mode allows you to query and modify the basic settings of the Star Trac Pro
Stepper.
Engaging Maintenance Mode
Press and hold the0 , 2and OK keys together.
A beep will sound and the “MAINTENANCE MODE” will display momentarily in the information
window.
Release all keys. “SERIAL NO XXXXX” will display in the information window.
Modifying the Maintenance Mode
The following keys are used to modify Maintenance Settings:
Upper and Lower Data Information Window SCROLL keys: Display the next and
previous settings.
Increase and Decrease Level Keys: Adjust the value of the displayed
setting up and down respectively, in increments of 1 unit.
OK Key: Updates (saves) the value of the display setting in the Flash memory, and exits
Maintenance Mode.
The Keypad Test can be used to verify that all keys are functioning on the display assembly.
To engage the Keypad Test
Enter the Maintenance Mode (see Settings – Maintenance Mode).

Press until Keypad Test is displayed in the information window.
Press to enter the Keypad Test.
Press each key on the display. Each time you press a key, the information window will display
which key has been pressed.
To exit the keypad test, press .
If any of the keys do not respond, they may not be functioning and the display keypad must be
replaced.
0helpful
1answer

Need to reset the drum counter on the AL 1740 sharp while changing to a used drum

Entering in the simulation mode:press Clear - Interrupt - 0 - Interrupt -Main code - Start -Subcode - Start.
When the clear all key is pressed the simulation mode is cancelled.When the interrupt key is pressed,the proces is interrupted and the screen returns to the subcode entering display.After cancelling the simulation mode be sure to turn OFF/ON the power and check the operation.
Main code 20 subcode 1 =Maintenance counter clear.
Main code 21 subcode 1 =Maintenance cycle settimg
subcode 2 =Mini maintenance cycle setting.
Maincode 22 subcode 1 = Maintenance counter display
subcode 2=Maintenance preset value display
subcode 3=Jam memory display
subcode4=Total jam counter display
subcode 5=Total counter display
subcode 6=Developing counter display
subcode 7=Developing preset counter value display
subcode 9=Paper feed counter display
subcode 12=Drum counter display
Maincode 24 subcode 1 =Jam counter clear
subcode 2=Trouble memory clear
subcode 7=Drum counter clear
subcode 8=Copy counter clear
Maincode 26 subcode 22=Language setting
Maincode 42 subcode 1=Developing counter clear
Maincode 43 subcode 1=Fusing temperature setting
Maincode 46 subcode 1=Copy density level adjustment
subcode 19 AE mode picture quality change
5helpful
4answers

Printing below standard

The problem could very well be clogged ink or air bubbles. There's no need to perform the regular cleaning any more as if it didn't solve the problem in the first few tries, it wont help, more force is needed.
You can perform a powerpurge (takes more ink, uses more force, solves more clogged ink), to perform it, follow these steps:
  • Enter maintenance mode, press menu, 2, 8, 6, 4 quickly (in two seconds).
  • When the buttons are flashing and the display says Maintenance, press 7, 6.
  • The display should now say "CLEANING ALL", press 3.
  • Now it should say something among the lines P_PURGE or POWER_P. Press Mono/Black Start.
  • After cleaning is done, you will get back to Maintenance. Press 9,9 to leave service mode again.
If the problem isn't solved now however, chemicals would probably be needed to solve it, as this is pretty much the only "function" you can use.
Not finding what you are looking for?

78 views

Ask a Question

Usually answered in minutes!

Top Life Fitness Exercise & Fitness Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Are you a Life Fitness Exercise and Fitnes Expert? Answer questions, earn points and help others