Intermatic T103 timer wired for 240V

I also have a T103, but it is wired for 240V. How should the clock be wired for 120V? Do I need to run a white neutral wire from the neutral in the electric box to the A terminal?

  • Anonymous Mar 19, 2014

    I need to know how to wire a Intermatic T1905P timer

×

1 Answer

Hippy_dd

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Mentor:

An expert who has written 3 tips or uploaded 2 video tips.

Habit-Forming:

Visited the website for 3 consecutive days.

  • Intermatic Expert 112 Answers
  • Posted on Aug 21, 2009
Hippy_dd
Intermatic Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Mentor:

An expert who has written 3 tips or uploaded 2 video tips.

Habit-Forming:

Visited the website for 3 consecutive days.

Joined: Dec 25, 2008
Answers
112
Questions
2
Helped
52789
Points
361

Yes u will, but u will have to make sure one of the motor wires are hooked up that way also, in case it has been moved, here is a link with the diagram u need

http://www.intermatic.com/~/media/files/intermatic/products/instructions/timers/t103%20-%20english.ashx

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Pool timer

You have the T103 timer rated 120-240. The clock motor part of timer is 120Volt. This is a very versatile timer, but confusing for non-electrician and electrician alike.
Solve problem by converting timer from T103 to the 240V T104 by changing clock motor from 120V WG1570 to 240V WG1573.
Buy wg1573 clock motor at WW Grainger or drillspot etc.
Resources:
http://waterheatertimer.org/How-to-replace-Intermatic-clock-motor.html
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T104
This simple fix is intentionally designed by Intermatic so their timers are not only adaptable to all electrical needs, but also can be maintained to last 25 years by replacing clock motors and trippers as needed

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Intermatic T103P Timer (120V) Wiring Guidance

Copy following link for T103 timer wiring options:
The clock motor is 120Volts, but clock motor can be changed from WH1570 to WG1573, and this action changes 120V T103 into 208-277V T104 timer:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

How to wire a intermatic timer T104 240 v to a 120v?

T104 is 240volt timer.
Timer has terminals A 1 2 3 4
T-104 clock motor must receive 240Volts to operate.
Clock motor wires are white-colored and can be seen connected to terminals 1 and 3.
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html
http://waterheatertimer.org/images/Back-of-WH40-2b.jpg

There are two work-arounds for using T104 for 120V.

1) Diagram 1 showing how to change wiring:
http://waterheatertimer.org/images/T-104-control-120V-Load-500.jpg
Move 240V clock motor wires to terminal 1 and A.
Connect 240V Hot leads to terminals 1 and A. This will power the 240V clock motor
Hot wire going to 120V load connects to terminal 2. This wire will be turned on each time timer turns on, and 120Volts will power the 120V load.
To complete 120V circuit, neutral wire that comes from neutral busbar in breaker box connects to 120V load.

To control additional 120Volt circuit, run jumper wire from terminal 1 to terminal 3.
Connect Hot to second load to terminal 4.

2) Second method is to change T104 timer into T103 timer:
http://waterheatertimer.org/images/T-104-control-120V-Load-2-5.jpg
Replace T104 240V clock with identical 120V clock motor from Grainger
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search
Neutral wires connect to terminal A.
Hot wire from Breaker connects to terminal 1
Hot going to Load connects to terminal 2

To control additional 120Volt circuit, run jumper wire from terminal 1 to terminal 3.
Connect Hot to second load to terminal 4.
0helpful
1answer

I have Intermatic timer WG 1573 208/277V 60Hz 3W stamped on the case. I would like to chage this unit to a 110V timer system if possible. (In other words just be able to switch clock motors) If this is...

WG1573 is a 240 Volt clock motor for T100 series timers.
This means you have T-104 timer.
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html
Image shown on link above is T104R outdoor timer.
T104 indoor timer is the same except door does not have rubber gasket.
Terminals are labeled A 1 2 3 4
If this is not your timer, then add a comment.

Following instructions will convert T104 240V timer to T103 120V timer

Clock motor can be replace with identical 120V clock motor from Grainger
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search

Timer mechanism snaps out and clock motor is located on back.
Remove clock motor with star screwdriver tip

Connect new clock motor wires to DIFFERENT terminals than before.
Old clock was connected to terminals 1 and 3
New 120V clock motor is connected to terminals A and 1

Wiring for 120V T103 is shown on link below.
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103
White neutral wire must connect to terminal A
Black hot wire must connect to terminal 1
0helpful
1answer

I have an Intermatic T103 DPST timer installed now (120v). The clock mechanism has failed. I bought Tork 1103 guts to replace it. The wiring is a bit different. Can u map for me which wires go to which...

T-103 has 120V clock motor with 5 terminals A 1 2 3 4
Tork 1101 has 120V clock motor with 4 terminals L 1 X 2

T103 is DPST and can control one-or-two 120Volt loads, or one-or-two 240Volt loads.
Tork 1101 is SPST can control one 120Volt load

Common ground between these timers one 120 Volt load
Changeover for one 120 Volt load:
White wires T103 terminal A go to Tork terminal X
Black wire T103 terminal 1 goes Tork terminals L and 1 (there is brass connector plate that connects L and 1 - if connector is missing, jumper between L and 1)
Black wire on T103 terminal 2 goes Tork terminal 2

If Load requirement is greater than T1101, Grainger sells T103 clock motor for $16
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search
http://www.grainger.com/Grainger/timer-accessories/timers/electrical/ecatalog/N-8hi

How to wire T103
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103
T1101 wiring manual
http://waterheatertimer.org/pdf/110111021103WIRING.pdf
2helpful
1answer

I having troble with my t103 timer to turn the lights on manualy i try to set the timer but for some reason doesn't work what can i do ???

T103 Intermatic timer has 120Volt clock motor and can control 120V or 240V Loads.
Wiring for timer is shown on following link:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103

Troubleshoot T103:
1) Manual override is working correctly, and it snaps crisp and clean, and Load turns on-and-off.
That means timer is basically good.

2) Next look to see if yellow dial is rotating.
If dial is not rotating, then 120Volt clock motor needs to be replaced.
Take photo of wiring and mark wires before starting.
Remove two white wires connected to screw terminals 1 and A.
Snap timer mechanism out of box, clock motor is on back of timer.
Use small star screwdriver to remove old clock motor.
Reattach white wires on terminals 1 and A, tighten screws very tight.
Reset current time: lift and rotate dial until current time lines up with silver pointer.
Grainger sells 125V clock motor:
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search

3) If dial is rotating, but gets stuck at certain times, or runs slow, then replace clock motor.

4) If dial is rotating, and trippers are attached to dial, but timer does not turn ON, then trippers are worn down and need to be replaced.
Grainger sells the T103 trippers
http://www.grainger.com/Grainger/INTERMATIC-Timer-Tripper-2E054?Pid=search

5) How Intermatic mechanical timers work:
Dial with ON-OFF trippers is rotated by clock motor.
Trippers on dial contact ON-OFF lever.
ON tripper pushes lever one direction.
OFF tripper pushes lever opposite direction.
Lever moves electrical contacts on back of timer that turn Load ON-OFF.
Manual override lever clicks back and forth with each ON-OFF action.

geno_3245_85.jpg
1helpful
1answer

Are all t104 timers 220 volt?

Yes, all T104s are 240Volt since the clock motor is 240V
Intermatic T101 and T103 have 120V clock motor

http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html
1helpful
1answer

Have intermatic t103 time switch, 240 v supply, clock motor not turning. what the correct wiring for the clock. 2 white wires...

Maybe-bad news.
The link below shows wiring for the T-104, T-103 and T-101
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103

For a 240V installation, the correct timer is the T-104, not the T-103
This is because the T-103 clock motor is 120V, and requires additional neutral wire on terminal A
The T-104 clock motor is 240V, and requires only the two hot wires and does not require a neutral.

I suggest you exchange timers and get the T-104
Or run another wire to nearby 120V receptacle and connect Terminal A to the white wires in nearby receptacles. This will give you the neutral that is needed for the clock.
In the absence of a Neutral wire, you can work-around by connecting ground wire to Terminal A >>> but this is NOT Code. You might use the ground wire as a temporary work-around until running additional neutral wire.
0helpful
1answer

How do I wire an intermatic t-103 timer switch

The T-103 has a 120Volt clock motor

From there, the wiring can go two directions depending on your Load voltage (load is the fan, light or motor that timer turns on-off)

Here is a link that shows exact wiring:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103

When wiring the T-103, steps 1-2-3 are true for 120V or 240V installation:
1) A white Neutral wire is always connected to terminal A (Neutral wire connects to Neutral busbar in breaker box)
2) A black Hot wire is always connected to terminal 1 >> this hot wire can come from 120V or 240V breaker
3) Black wire going to Load (fan, light, motor) is always connected to terminal 2
The following step is true for 120V Load
4) if Load is 120V, then white wire from Load connects to terminal A
The following steps are true for 240V Load
5) Only the neutral wire connects to terminal A as described in (1
6) The second Black hot from breaker box (240V has 2 hot wires) connects to terminal 3
7) The second White going to Load connects to terminal 4

Here are 2 more links that show how 120V and 240V circuits are wired
http://waterheatertimer.org/See-inside-main-breaker-box.html
http://waterheatertimer.org/B220C.html
1helpful
1answer

How do you wire a intermatic t103

I'm looking at the T-103 sitting here in my office.
Terminals are labeled: A 1 2 3 4
I have about 10 different Intermatic timers on the shelves & each is a bit different

The T103 has a 120Volt (or 110V) clock motor
You need a white Neutral wire to operate the T103 clock

120V: Let's say your Load (light, fan, pump) is 120V
The white Neutral from breaker box connects to Terminal A
The 120V black Hot wire from breaker box connects to Terminal 1
The black wire going to Load (fan, light, motor) connects to terminal 2
The white wire going to Load connects to terminal A along with the Neutral
Ground wires connects to green ground screw
If your wires from breaker and wires to load are wired in reverse, the timer will turn ON the Load but the timer will not shut the circuit OFF.
To test which wire is Hot and Neutral, look at explanation at bottom of page.

240V: Let's say your Load is 240 Volts (or 220 Volts)
The clock motor is still 120V so you still need a white Neutral wire connected on Terminal A
Now you have 2 Hot wires coming from breaker box
Hot wire 1 from breaker box connects to Terminal 1
Hot wire 2 from breaker box connects to Terminal 3
Wire 1 going to Load connects to Terminal 2
Wire 2 going to Load connects to Terminal 4
Ground wires connects to green ground screw

What if you don't have a Neutral wire and you are wiring a 240V circuit?
240V circuits normally have 2 hots and a ground, but no neutral
Buy the T-104 timer
The T-104 has a 240V clock motor
Wiring for the T-104 is exactly the same as 240V wiring shown above for T103 EXCEPT there is no Neutral on Terminal A, and Terminal A is bare
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

How to test which wire is Hot
Test requires wires with live electricity >>> this is not advisable without precaution
Stand on dry boards, do not touch anything metal, wear dry clothes, do not hold screwdriver in mouth, wear gloves, tape tester leads to wood sticks so hands are away from power
Remove wires from terminals
Separate wires so they can be tested
Turn on power
Test each wire to bare ground wire
Tester lights up on Hot wire(s)
If circuit is 120V, then there is only one Hot wire
If circuit is 240V, then 2 wires will test hot to ground >> these wires will be Hots 1 & 2
Test assumes circuit breaker is functioning normally.

How do you test for neutral?
If you have 120V line with only 1 hot wire, then one of the white wires will be Neutral?
Test Hot wire to each white wire
Tester lights up on neutral
Not finding what you are looking for?

1,008 views

Ask a Question

Usually answered in minutes!

Top Intermatic Hardware & Accessories Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you an Intermatic Hardware and Accessory Expert? Answer questions, earn points and help others