Treager smoke auger won't turn - Traeger Industries Grilling

1 Answer

tau1618

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

  • Expert 233 Answers
  • Posted on Dec 24, 2014
tau1618
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

Joined: May 21, 2010
Answers
233
Questions
0
Helped
126075
Points
763

If the auger won't turn because it's jammed, here's details direct from Treager
Treager smoke auger won't turn - treager-smoke-auger-turn-2xyy4ak2ishhqrxtr0fk0i44-4-0.png

Elswise, I would check your electrical on the back of your control panel. There should be three sets of two-wire leads: (1) Purple/White=Hot Rod; (2) Orange/White=Induction Fan; and (3) Red/White=Auger. Obviously, check the Red/White leads for voltage and continuity.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers

Treager BBQ will not get hot at all.

Ensure your fire box is cleaned out and ventilation holes at the base are not obstructed. Ensure the induction fan is operating and moving air into the fire box.

According to Treager FAQ:

"I've been noticing that my grill temperature keeps dropping lower. What is the problem?
You need to "true" your auger. To do this:

Run the unit out of pellets.
Remove the allen screw and nut out of the auger and motor shaft.
Try spinning the auger shaft over the motor shaft. The auger shaft should spin freely over the motor shaft without binding.
If the auger binds, loosen the 7/16th inch bolts on the motor bracket and move bracket until you can rotate the auger shaft over the motor shaft. Then re-tighten 7/16th inch bolts. Make sure auger shaft still rotates over motor shaft, or repeat step 4 again until it does.
Reattach auger and motor shafts using the screw and nut which you removed in step 2."
0helpful
1answer

Treager is overheating on smoke setting

Make sure you are leaving it open long enough when you first turn it on. Everything in the smoke chamber needs to burn up before you begin. There also may be grease buildup in the bottom of your smoker that is catching on fire. If neither of these two possibilities work, contact Traeger support https://www.traegergrills.com/support
0helpful
1answer

Treager is overheating

Make sure you are leaving it open long enough when you first turn it on. Everything in the smoke chamber needs to burn up before you begin. There also may be grease buildup in the bottom of your smoker that is catching on fire. If neither of these two possibilities work, contact Traeger support https://www.traegergrills.com/support
0helpful
1answer

My yardmachine snow blower 8hp auger won't turn. I replaced the cable and belt but it still won't turn. What else could be wrong?

Check the auger shear pins replace if necessary with correct parts(not regular bolts).
If auger and the impeller are not turning your cable is out of adjustment.
If only the auger doesn't turn, and the shear pins are ok then the brass/bronze gear has shredded which is why proper shear pins must be used. Donyboy73 on youtube show how to replace that gear on an older but similar MTD affiliated blower.
0helpful
2answers
0helpful
1answer

The pellet auger on my traeger doesn't feed pellets. It is not stuck as I can turn it with my fingers. Any ideas? Are there any resets? Everything else seems to be working OK.

Call Treager direct
They have a great customer service dept and if you have an issue with a motor or control board they are really good about sending replacements
800-372-3437
If this helps please leave a comment
Mar 28, 2010 • Grilling
0helpful
1answer

My grill stopped smoking after being on for some time and had gotten cold. I restarted it and it start smoking vigorously very quickly. When I turned it to medium there was a internal explosion of sorts as...

I had the same thing happen with my Treager.

However when mine back drafted ( the explosion ) the blew the door open so hard it bent it, I had just turned away or I would have taken that blast in the face, from a distance of 3 feet - could have been one of those OUCH moments

When i talked to Mike Treager he said NEVER start your grill with the door closed And that if you are smoking with low heat before you turn the grill off run it on high for 5 minutes to burn up anything left in the ash pot
I do and have never had a problem since and I rarely need to clean it out as the high fire burns 99% of everything in the ash pot
Not finding what you are looking for?

633 views

Ask a Question

Usually answered in minutes!

Top Traeger Industries Grilling Experts

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Kardoc

Level 3 Expert

7503 Answers

Are you a Traeger Industries Grilling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...