Model No Required below Model No AH-X18MEV Self diagnosis mode given
1. Indoor unit
(AH-X18MEV, AH-X18MEV-1, AH-X24MEV, AH-X24MEV-1)
To display the self-diagnosis, hold down the AUX button for over 5 seconds on the indoor unit when the indoor unit is not operating.
• The operation lamp (red), timer lamp (orange) and Super jet lamp lighter) flash to indicate the information of malfunction.
(Display of self-diagnosis result)
The operation lamp (red) and the Super jet lamp (green) flash in synchronization with the timer lamp (orange).
(AH-XP18MV, AH-XP18MV-1, AH-XP24MV, AH-XP24MV-1)
To display the self-diagnosis, hold down the AUX button for over 5 seconds on the indoor unit when the indoor unit is not operating.
• The POWER CONSUMPTION indicator indicates the information of malfunction by showing the main category error (number) and the sub-category
error (-number) alternately in 1-second intervals.
Example: Compressor high-temperature error
Remark
• If the power cord is unplugged or the circuit breaker is turned off, the self-diagnosis memory is lost.
AUX
Operation lamp(red)
Timer lamp(orange)
Super jet lamp(green)