Scanner feed trouble.
The scanner does not complete feeding in the specified time.
Mirror unit abnormality.
The scanner wire is disconnected.
The origin detection sensor abnormality.
Mirror motor harness abnormality.
Use SIM 1-1 to check the mirror reciprocatingoperations.
When the mirror does not feed.
Check for disconnection of the scanner wire.
Check the harness and the connector between the mirror motor and the MCU PWB.
Replace the mirror unit.Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home positionsensor.
From the service manual:
http://www.scribd.com/doc/74632095/ARM206-M161-SM-GB
×