The cable that came with the generac has 4 control wires in it. The connection block in the generator and the transfer switch has 6, am I missing something or do 2 wires not have to be connected?

  • Anonymous Mar 13, 2012

    the other two are probably for the battery charger circuit

×

3 Answers

Anonymous

Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

  • Contributor 33 Answers
  • Posted on Dec 01, 2009
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

Joined: Dec 01, 2009
Answers
33
Questions
0
Helped
18776
Points
66

Older model Generac only haver 4 control wires:
N1
N2
23
194
if it is the included wiring harness the wires should have their numbers stamped on the jacketing and a sticker should designate the proper screw to mount it to in both the ATS and the generator housing. hooking these wires up incorrectly often results in blown fuses and/or damage to the control board in the generator.

RSG000

Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

  • Contributor 26 Answers
  • Posted on Jul 09, 2009
RSG000
Contributor
Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

Joined: Jul 09, 2009
Answers
26
Questions
0
Helped
17575
Points
41

Just 4. I install generac switches and generators

Ad

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Mar 13, 2012
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Mar 13, 2012
Answers
1
Questions
0
Helped
2056
Points
1

The 4 wire you have in the cable are utility sense and the start circuit. the two extra terminals that you are talking about are likely the battery charge circuit

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
3answers

Generac Guardian Standby Generator 04760 15KW LP won't stay running

Turns out it was the Manual-off-Auto switch that was bad. My DVM showed a voltage drop across the switch. The controller wasn't getting enough power.

One good thing about it was it forced me to really study the schematics to understand how everything worked. I'm now in the process of designing my own esp32 based controller, with wifi connectivity, to replace the stock control board.
0helpful
1answer

I need the schematic and wiring drawings for a RTSN100A3 transfer switch connect to a GOO70310 generator serial #3001798687

Generac Power Solutions | Service and Support | Online Product Support | Generac Power Systems

www.generac.com/service-support/product-support-lookup/product-support-details?productid=a834ffa6-fce4-4df9-bb9d-98968e97a5b1&serialNumber=3001798687®istered=false
2helpful
2answers

Generac generator won't turn off in automatic

It is possibly a transfer switch issue, not the generator control board. Have an electrican kill utility power, let it start and run, then disconnect the sensing wires in the ATS. If it stops problem is ATS
0helpful
1answer

For these 4 control wires. How many watts do they consume. I have a generator 150ft away from the transfer switch, should these 4 18AWG control wires upsized?

No. They are fine. The voltage is 220. But the amperage is nearly nothing because its just for signaling the generator and switch when the powers out. I install, repair, and service generac products for a living.
0helpful
1answer
0helpful
1answer

Generac generator remote start

si tiene transfer automatico solo poner un swicht en hilo 1N para cortar senal de entrada al generador del utility power que sensa la presencia de voltage en caso de falta arranca el generador en forma de prueba
4helpful
4answers

I have a new Generac 20KW Propane generator with a rtse 200A3 automatic switch. I had an electrician install the switch and make the connections from to the generator. The generator is blowing the 7.5 amp...

Sounds like the electritian wired something wrong. Control wiring for that generator should be:
N1 and N2 = 240 vac utility input
Wire 0 = ground
Wire 194 (15B) = + battery
wire 23 = transfer signal
0helpful
1answer

Generac 4456 does not start on power loss

I install and work on these everyday. If you hooked up the transfer switch you probable have a control wire wrong. check the utility power sense wire. That lets it no when to start in auto. it could be a relay or fuses. or a control board.
Not finding what you are looking for?

2,066 views

Ask a Question

Usually answered in minutes!

Top Generac Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Brad Brown

Level 3 Expert

19187 Answers

Paul Bade

Level 3 Expert

1818 Answers

Are you a Generac Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...