Sharp R-1870 Convection/Microwave Oven Logo

Related Topics:

A
Anonymous Posted on Sep 02, 2013

Cuts off after 59 seconds - Sharp R-1870 Convection/Microwave Oven

  • HotCap Jan 27, 2015

    I bought a Sharp Microwave Oven with Sensor, Grill and Convention functions, R-967(SL)M, a few years ago in London, United Kingdom. Problem: Now, each time the timer counts down to 1 second (for example, 1 sec. or 2 mins. 1 sec. or XX mins 1 sec.), the heating function just stop as long as the timer shows 1 second. In addition, I relocated to Hong Kong and the local Sharp customer service refused to provide any repair service (even if paying!) since I did not buy the product model in Hong Kong! The warranty period has ended, hence there is not an issue with warranty service. Appreciate if any expert(s) out there could kindly provide assistance or at least offer a direction/suggestion which I could pursue to get the appliance back to working again. Thank you!

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Sharp microwave r1870 only runs for 59 seconds

If it consistently runs for exactly 59 seconds, and shuts off, it's probably the control panel.

If it runs approximately that length of time, you might have a defective thermal protector on the magnetron, or the magnetron is running too warm for some reason.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/david_29ad5d1dd86564b0

0helpful
1answer

Microwave stops after 59 seconds

Check that a "favourite" setting has not been selected. The unit may think that is the time that you want to cook. Im not sure about your model but see if there is any clear or cancel buttons to clear any pre programmed selections. If not, unplug the machine for 15 minutes to reset the controller and try it again.
0helpful
1answer

My Sharp R-975 Microwave after settin the timer and starting only runs for 59 seconds and stops, I can press start again and it goes for another 59 seconds

This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

I'm not sure this is a US model or if parts are still available, so look up Sharp in your country.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

microwavesvc_30.jpg
1helpful
1answer

Amana OTR Convection Microwave runs 59 seconds and shuts off

This sounds like either a thermistor or a damper switch/motor problem.
Amana's technical support line is 866-426-2621. This is the commercial side but they should be able to get you in touch with the domestic side.
2helpful
1answer

No matter what time i put in it cuts off in 60 seconds on a sharp

This sounds like a bad damper switch or motor. Double check the shut off time....... see if it's actually 59 seconds..
When you unplug the unit from the wall for 2 minutes then plug it bad in, you should be able to faintly hear a motor run for a few seconds. This is the damper motor running. This will verify that the motor is operating.....
Also, check the thermistor.
0helpful
1answer
0helpful
1answer

I have a sharp r959slm microwave. what ever time you set whether convection or normal it cuts out after 59 seconds. It makes a noise simular to coggs turning. is it something i can tackle or not

This is a problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

We're happy to help and we appreciate your thoughtful rating of our answer.

c0a87f2.jpg
0helpful
1answer

Sharp r95 combination oven only stays on foe 1m before switching itself off

Check the damper motor - this closes a small metal door usually located behind the magnetron tube. If the unit runs exactly 59 seconds then cuts off, then that's most likely your problem.
Not finding what you are looking for?

104 views

Ask a Question

Usually answered in minutes!

Top Sharp Microwave Ovens Experts