Wega Mininova EPU Espresso Machine Logo

Related Topics:

Anonymous Posted on Aug 15, 2013

Slow water coming out of Group heads - Wega Mininova EPU Espresso Machine

1 Related Answer

EsWorld

Ernest R

  • 1618 Answers
  • Posted on Apr 17, 2010

SOURCE: miniwx epu no water coming from group head to cup

Since there is no water at the solenoid, then the blockage must be at the metering jet, which sits under the nut on top of the group, turn of water supply and be careful when removing nut do not damaged o-ring if it is not a teflon O-ring, you might have a leak. Clean out jet and filter then reassemble.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I have a Nuova Simonelli Mac Cup 2 Group. 1 group works fine. 2nd ... NO WATER gets to the group head.

It sounds like you may have a clog in the water line or the tubing that leads from the water tank to the 2nd group head of your coffee machine. To address this issue, you can try the following steps:

1. Disconnect the tubing from the group head and the water tank.
2. Flush the tubing with hot water to remove any buildup or debris.
3. Check the inlet and outlet holes on the group head to make sure they are not clogged or obstructed.
4. Reattach the tubing to the group head and the water tank, making sure it is securely connected.
5. Test the water flow to see if it is now flowing properly.

If the water still does not flow after following these steps, you may need to disassemble the group head and inspect it for any further blockages or damage. If you are not familiar with this type of maintenance, it is recommended to seek assistance from a professional.
0helpful
1answer

Rancilio coffee machine .no water coming out of the group head . steam coming of the group head

Hi Ewah,

If you are getting steam from the group and no water when you turn on the water button - then you may have a group blockage.

The fix depends on the type of machine you have.
If it is a commercial type - then call in a qualified coffee technician.
If it is a domestic type like rancilio sylvia, the you could try to descale - maybe too late, but worth a go.JURA descaling tablets
If when descaling, no water is coming from the group try leaving the steam tap open when asking for water.That way you may get the descaler liquid moving inside the boiler and it may clear the solenoid valve blockage.
If no joy with that you may need to replace solenoid valve.
230V 9W PARKER SOLENOID
Domestic machines need regular descaling to avoid group blockages.
0helpful
1answer

Espresso shots pour very slow for both the single and double shots.

Did you try adjusting the group head screw? And/or cleaning and checking the valve in the group head? Good visuals and instructions here: https://myprojectsandmods.wordpress.com/2014/10/27/delonghi-ec702-espresso-machine-no-water-flow-fix/
0helpful
1answer

Water coming slow

filter plugged or pressure weak.
0helpful
1answer

Rancilio Classe 7 no water coming through left group head

https://www.espressoparts.com/resources/barista-basics/no-water-at-the-group
0helpful
1answer

The water flows very slow on group 1. On the other group it flows ok.

There could be a couple of reasons for this. The simplest could just be that you need a new group (brew) solenoid valve, yours might not being opening fully. You could also have a clog some where. Take the shower head out and soak it in PuroCafe over night. If that doesn't fix it you would have to start checking the jets in the head and or the tubing that supplies water from the heat exchanger to the groups.
0helpful
1answer

Hi, no water through e61 group head ?

Check the metering jets and filter on the top of the group heads.
1helpful
1answer

My e61 group head on my Diadema UNICO Splendor exhaust port probs

There might be one of 2 things going on,
1- the exhaust tube is blocked.
2- one of the three gaskets in the group is on backwards.
0helpful
1answer

No water coming through group head

Remove the shower screen and clean. If shower is clean then line to head is clogged.
1helpful
2answers

Astra Mega II <----Need help!

The left grouphead sounds like a different problem than the right group head. For the left grouphead, I would start by replacing the group electro-valve. With hard water, this can cause the valve to remain in the closed position even though the water pump is running.

For the right group head, I would want to see this happen. Usually, if the gaskets haven't been replaced in a while (if you are busy, your 'while' may be quicker than others), I would evaluate the condition of the rubber gasket. I would also look at whether you are tamping too much espresso grounds into the portafilter. This can cause a similar symptom as a bad gasket.


Not finding what you are looking for?

135 views

Ask a Question

Usually answered in minutes!

Top Wega Coffee Makers & Espresso Machines Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Sulejman Sulejmani
Sulejman Sulejmani

Level 2 Expert

138 Answers

Kolbrun...

Level 3 Expert

1228 Answers

Are you a Wega Coffee Maker and Espresso Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...