Cleaned cond. coil. turned ref off for about 1 hour in case evap. coil was frosted over left fresh food door open for about one hour.after running for two hours ,freezer temp dropped from 21 deg and falling. fresh food only dropped from 61 deg to 59.

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Contributor 478 Answers
  • Posted on Mar 12, 2009
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Mar 11, 2009
Answers
478
Questions
2
Helped
164358
Points
61

An hour aint enough. Turn off fridge, use blow drier, thers a huge ice cube behind that sheetmetal wall back of freezer inside wall, it takes 48 hours at 75 degrees to let it do itself. Listen for inside motor, its obvious. If so, you hve a defrost problem.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Igloo refrigerator's freezer: -16 deg. Fridge: 60 deg. No evap fan & duct from freezer to fridge. Cond coil clean. Discharge line warm. T/STAT@coldest temp. Fridge gasket seals. Condensate drain clear

freezer is working fine, refrigerator won't go above 60 degrees.

www.shopyourway.com > Manage My Life > Questions
Freezer is working fine but fridge won't go about 60 degrees. Cleaned out pass through from freezer to fridge, clean vents, and cleaned coils. All to no avail.Missing: gloo

Beckly Powerful Suction Cup Handle No Tools Necessary!

www.amazon.com > ... > Bathtub Appliques

Amazon.com, Inc.
Rating: 3.6 - ‎85 reviews
Just Turn 60 Degrees and place on any Flat Smooth surface. For Bath Safety and Cabinet Doors Also Fridge Accessory. Beautiful ... No tools, no glue! No need ...

[PDF]Operate Refrigerator In Room Warmer Than 60°F


0helpful
1answer

Why is my refrigerator temperature dropping and freezing food, but freezer temp holds.

Hello Michael, I appreciate your inquiry!

Based off the information you have provided your Frigidaire refrigerator is dropping the temperature within the fresh food side. The damper is located within the back of the fresh food side and this part will open and close so that the cold air from the freezer will come into the fresh food side. It is possible that this damper can be stuck open or staying open for too long. Do you notice any frost developing within the freezer? If so, please perform a manual defrost on the refrigerator and you can do that by disconnecting power from it for at least one hour. If there is no frost within the freezer then check to make sure no packages are holding the damper open. You may need to replace the damper or the damper motor and I would recommend having a professional technician out to perform proper replacement repairs. Best of luck! -Matt

0helpful
1answer

W have a amanda ref model AF12538AEW SER#12987374LX putin to storage a year ago. Worked fine. Pulled it out of storage. Freezer get 34deg. Ref 40 deg. Any thought whats wrong?

THE UNIT HAS MOLD BUILD UP IN THE EVAP COIL IT NEEDS TO BE CLEANED PROPERLY BY REMOVING THE FREEZER RACKS AND THE SCREWS IN THE REAR OF FREEZER COMPARTMENT THEN USE HOT SOAPY WATER IN A SPRAY BOTTLE AND CLEAN THE EVAP COIL AND MAKE SURE THAT THE DRAIN TUBE ISNT CLOGGED REINSTALL PARTS THEN TURN ON BOX CHECK TEMPARATURES. FOOD AND MOLD GETS INTO THE EVAP COIL AND MOVING DOORS AND FLAPS AND AIR PASSAGES CLEAN UNIT WITH HOT WATER AND BLEACH MIXTURE TO KILL MOLD SPRAY OUT ENTIRE BOX WITH MIXTURE OF SOAP AND BLEACH WATER AND RINSE COMPLETELY
0helpful
1answer

Not freezing enough

You might have ice building up on your evaporator coil. That ice serves as an insulator and prevents the internal freezer temps from going down to design parameters. The ice buildup is caused by the defrost mechanism not working - check the timer or the defrost heating element.
1helpful
1answer

Ge moogram Model# PSB42YSXSS The first time I went to this unit temp freezer was 12 but ref was 58 cleaned out condenser next morning Freezer 0 ref 37 week later fr is 40 ref58 water is leaking from evap...

Hey Rkraft,

i may have answered that question in the comment ya posted on the other Monogram

But now as i think about it how is the frost pattern on it is part of the evap coil covered in ICE (not frost) that could be a sign of a sealed system problem but only if part of the evap coil is iced up and the tube i spoke about on in that other comment isnt frozen


GENE
0helpful
1answer

Freezer temp is set to 5 and fresh food temp is blinking 4, watering running from fresh food side. Fresh food side is not working. What is the problem

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

If you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
1helpful
1answer

What is the best setting for the freezer and the refrigerator to save electricity?

to save the most electricity.??? turn off // ha ha // to run any frig properly try to keep ref side ( fresh food at 36 to 38 deg and freezer if it has ice maker around 0 to 5 deg . . . to save power . keep the coils clean and door seal clean . make sure doors close properly and seals are good . mm
0helpful
1answer

My upright Frigidaire freezer is not freezing completly. The food is still frozen but when I put in my new popcilcles to freeze ( a week later) they are slushy when they should be completly frozen solid....

Check temp. in freezer shoud be 0 to -5 Deg. Check condensor if dirty clean some units had a recall on diers cap.tube to far in dier also check for ice on back wall if icedup check defrost heater and defrost timer check evap. fan make sure it's turning.
0helpful
2answers

Left not transfering cold enough air to right side. doesn't get colder than 50 degrees, why?

Remove back panel of freezer (where you see the frost) and melt the frost with a hair blower. The frost blocked evaporator coils are not allowing air to pass over the cold coils, so no cold air is able to get to the fresh foods section. You will most likely need to replace the defrost heater at the bottom of the evap coils to prevent this from reoccurring in two weeks time.
0helpful
1answer
Not finding what you are looking for?

254 views

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...