Avanti at380 treadmill,hasn't been shifted or anything like that,just went that way at startup.what can I do?
DescriptionError 09 checks lower PCA memory locations during the power up test sequence. If a fault isfound during the power up test sequence, error 09 will be displayed. This error code is only usedon products utilizing the dual microprocessor system.Possible Causes1. This error message almost always indicates a lower PCA problem when it is consistentlydisplayed. Failures causing this error message to be displayed are rare.Possible Remedies1. If the error message is consistently displayed when the unit is powered up, the lower PCAshould be replaced. It is possible to see this error message displayed intermittently due toexternal causes. If the units A.C. input significantly dips during the power up test sequencethe test could fail resulting in this message being displayed. Treadmills operating onnon-dedicated A.C. circuits may see this message displayed on an intermittent basis.God bless you
SOURCE: I didn't receive my instructional or users manuel for my Avanti AT380 Treadmill
GO THIS WEBSITE AND DOWNLOAD SIMILAR MODEL FROM AVANTI USER GUIDE:
http://www.manualsnguides.com/results.php#.TtV56Xpc71s
SINCERELY
http://www.manualsnguides.com/document.php?iddocument=Dwhbzqg9ue#.TtYPiXpc71s
User's GuideAVANTI
928S
Treadmill AND DOWNLOAD AND YOU MUST PAY FOR IT. YOU DO NOT HAVE ANOTHER SOLUTION. AVANTI IS DOES NOT ANY WEBSITE WITH CUSTOMER SERVICE. ONLY COMPANIES THAT SELL THE EQUIPMENT BUT WITHOUT TECHNICAL SUPPORT.
SINCERELY.
E.CUADRA
730 views
Usually answered in minutes!
×