We have a Maytag MEDE300VF (3000 series, i think) front loading dryer. During the drying cycle, the dryer door opens even though the clothes have not completed drying.
Chances are the little plastic latch keep is broken. Look at the door and locate a peice that will press into the front area where the clothes go in.
Once you see it, check the keeper and see if it is broken. The door should not just pop open.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
A fairly common problem! The official instructions are
Before using your dryer, wipe the dryer drum with a damp cloth to
remove dust from storing and shipping.
1. Load clothes loosely into the dryer and close the door. Do not
pack the dryer. Allow space for clothes to tumble freely.
2. Turn the Cycle Control knob to the recommended cycle for the type of load being dried. Use the Energy Preferred Automatic Setting (,) to dry most heavyweight and medium weight loads. See "Drying, Cycle, and Temperature Tips."
3. Select a temperature setting on models with a Temp/Fabric selector. The cycle descriptions include temperature setting suggestions.
4. Push the START button.
Stopping and Restarting
You can stop your dryer any time during a cycle.
To stop your dryer
Open the dryer door or turn the Cycle Control knob to OFE
NOTE: The Cycle Control knob should point to an Off area when
the dryer is not in use.
To restart your dryer
1. Close the door.
2. Select a new cycle and temperature (if desired).
3. Press START
Extracted from
http://www.manualslib.com/manual/511763/Whirlpool-Lte5243dq.html?page=10#manual
oooow,,,temper temper,,,,take a deep breath,,,
i think the temp censor has stoped working thats why its not getting very hot its that or the heating coil/s are broken,,also check the air vents at the back are not blocked up if so its not getting any air to it,,,
then go out and find a big stick,,,and batter it with the stick,,,
this realy wont help fix it,,but it will make you feel soooo much better?
There is either a switch or a sensor that tells the dryer when the door is opened. If it's a switch you can repair it yourself most likely, but if it's a sensor it will probably need to be replaced.
open it and see where the leack come from it might be the drain pump and it easy to replace or it might be a hose that got burst... see if you can open it from the back or the bottom front
if she could open the door during wash cycle the door lock is broken and you may need a new one also inspect pumpn and tub to pump hose for foreign objects
Is this a front loading machine? Also whats the model number when you open the door? If this is a front loading machine and you haven't been using HE soap, it's almost certain it's the brearing.
Sounds like you need a blower wheel.you will need to remove the front panel and the houseing under the front panel.It is located on the bottom front laft side. if you need help on assembly or disassembly let me know hope i fixya :)
Hello
ALARM CODES
Alarm
code Description of fault User
code Effect
E11 Problems with water fill in wash phase E10 Cycle PAUSED 8.2
E12 Problems with water fill in drying E10 Cycle PAUSED 8.3
E21 Problems with water drain in wash phase E20 Cycle PAUSED 8.4
E22 Problems with water drain during drying or drying
condenser blocked E20 Heating phase skipped 8.5
E31 Analogic (electronic) pressure switch circuit faulty --- Cycle blocked
with door closed 8.6
E32 Incorrect calibration of analogic (electronic) pressure
switch --- Cycle PAUSED 8.7
E33
Incongruency between level of analogic (electronic)
pressure switch and level of anti-boiling pressure
switch 1
--- Cycle blocked
with door closed 8.8
E34 Incongruency between level of electronic pressure
switch and level of anti-boiling pressure switch 2 --- Cycle blocked
with door closed 8.9
E35 Water level too high --- Cycle blocked with door
closed and water drain 8.10
E36 "Sensing" circuit of anti-boiling pressure switch 1 faulty --- Cycle blocked
with door closed 8.11
E37 "Sensing" circuit of anti-boiling pressure switch 2 faulty --- Cycle blocked
with door closed 8.11
E38 Pressure chamber blocked --- Heating phase skipped 8.12
E41 Door open E40 Cycle PAUSED 8.13-14
E42 Problems with door closure E40 Cycle PAUSED 8.15-16
E43 TRIAC which powers the door interlock faulty E40 Cycle PAUSED 8.17-18
E44 "Sensing" circuit of door delay interlock faulty --- Cycle blocked 8.19
E45 "Sensing" circuit of door delay interlock triac faulty --- Cycle blocked
with door closed 8.19
E51 TRIAC which powers the motor short-circuited --- Cycle blocked with door
closed (after 5 attempts) 8.20
E52 No signal from tachometric generator --- Cycle blocked with door
closed (after 5 attempts) 8.21-22
E53 "Sensing" circuit of motor TRIAC faulty --- Cycle blocked
with door closed 8.23
E54 Relays (motor) contacts faulty --- Cycle blocked with door
closed (after 5 attempts) 8.23
E61 Insufficient heating during washing --- Heating phase skipped 8.24
E62 Overheating during washing --- Drain, end of cycle 8.25
E63 Insufficient heating during drying Heating phase skipped 8.26
E64 Overheating during drying --- Heating phase skipped 8.27
E66 Power relay to heating element faulty --- Drain, end of cycle 8.28
E71 NTC wash sensor faulty --- Heating phase skipped 8.29
E72 NTC sensor on drying condenser faulty --- Heating phase skipped 8.30
E73 NTC sensor on drying duct faulty --- Heating phase skipped 8.31
E84 "Sensing" circuit on circulation pump triac faulty --- Drain, end of cycle
(door open) 8.32
E85 Circulation pump faulty --- Drain, end of cycle
(door open) 8.33
E91 Communications error between main PCB and user
interface --- --- 8.34
E93 Configuration error E90 Cycle blocked 8.34
E94 Incorrect configuration of washing cycle E90 Cycle blocked 8.34
EF1 Drain filter blocked LED-EF0 --- 8.35
EF2 Excessive detergent LED-EF0 --- 8.35
Regards David Marsh