Zebra Symbol Technologies MC909X-G Series Barcode Scanner Logo
LeoM Posted on Dec 06, 2012

Couldn't get PM power status MC9090

On boot up, get error couldn't get PM power status, Says to close battery door, which is closed. And an error appears throughout the screen stating the message about.

3 Answers

Marcin J

Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

Habit-Forming:

Visited the website for 3 consecutive days.

New Friend:

An expert that has 1 follower.

  • Contributor 8 Answers
  • Posted on Dec 08, 2015
Marcin J
Contributor
Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

Habit-Forming:

Visited the website for 3 consecutive days.

New Friend:

An expert that has 1 follower.

Joined: Dec 08, 2015
Answers
8
Questions
0
Helped
23819
Points
17

Clean ribbon cable connector and connector at board

Frantiek Tma

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 3 Answers
  • Posted on Nov 10, 2015
Frantiek Tma
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Nov 10, 2015
Answers
3
Questions
0
Helped
6926
Points
6

I figured out, that the problem i caused by badly connected motherboard cable. I solved it by assembling the "display etc" part with the motherboard firts, then connecting the MB cable firmly, and finally put together with the "gun holder/battery closet" and secure it with screws

Ad

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 4 Answers
  • Posted on Dec 15, 2012
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Dec 15, 2012
Answers
4
Questions
0
Helped
6663
Points
4

Mc9090 does not have a battery door?! You should try a reflash by SD card or Activesync, you will need access to support.symbol.com and possibly a service contract to access the firmware.

4 Related Answers

Anonymous

  • 1 Answer
  • Posted on Jul 12, 2012

SOURCE: Hi, unable to boot mc9090. (warmboot

909XCLEANBOOT.ZIP
This file is intended for use when a CLEAN BOOT of an MC909X WM 5.0 device is required. Unzip the contents of this device to either the root of an SD Card (and place the SD Card in your device) OR the TEMP folder. Then follow the UPDATE LOADER boot instructions below.

909XCLEANBOOTANDBLANK.ZIP
This file is intended for use when both a blank Application Folder and a CLEAN BOOT of an MC909X WM 5.0 device is required. Unzip the contents of this device to either the root of an SD Card (and place the SD Card in your device) OR the TEMP folder. Then follow the UPDATE LOADER boot instructions below.

There are two methods to perform an Update Loader Boot on MC909X:
Method 1
1. Navigate to the location where the ZIP file was unzipped
2. Tap 'StartUpdLdr.exe'
3. After 20 seconds or so, the device will perform an Update Loader boot which will cause the PKGS.LST file deposited on the device to be processed. Leave the device on A/C power during the Update Loader process

Method 2
1. Press the primary battery release on the mobile computer to partially eject the battery from the mobile
computer.
2. On an MC9090-G, while the battery is partially released, simultaneously press and release the trigger and
the Power button.
3. On an MC-909X-K or MC909X-S, while the battery is partially released, simultaneously press and release
the left scan button and the Power button.
4. Push the battery to fully re-insert it in the mobile computer. One audible click can be heard as the battery is
fully inserted.
5. The mobile computer initializes. During this time press and hold the trigger used on step #2 or step #3 (as appropriate) and place the device on A/C power either by placing it in a cradle or a CAM.
6. The device will invoke an Update Loader boot, which will cause the PKGS.LST file deposited on the device to be processed. Leave the device on A/C power during the Update Loader process.

When the device has completed the process it will return to the Windows Mobile ""Tap the screen to set up your Windows Mobile-based device" screen. At this point, if you used an SD card, please remove it from the device. If you placed the files in the TEMP folder, they will be automatically erased by the CLEAN BOOT process.


The files can be downloaded from:
https://docs.symbol.com/downloads/909XCLEANERS.zip but this didnt work for me i use another similar ones, probably its because you will need to find the properly version.
Regards

Ad
thesuperdude

Oscar Suarez

  • 97 Answers
  • Posted on Mar 26, 2009

SOURCE: Symbol MC9090 scanner disabled

You may need to reflash the OS. you can normally download it from symbol webpage. you will need a cradle and an SD card.

thesuperdude

Oscar Suarez

  • 97 Answers
  • Posted on Mar 26, 2009

SOURCE: Error A000000B scanner support dissabled

You have a hardware problem with the scanner i am afraid. this will have to be sent for repair.

Anonymous

  • 47 Answers
  • Posted on Nov 04, 2009

SOURCE: i can't boot a Symbol MC9090.

She's Broken...contact your dealer or the Motorola Help Desk at 1-800-653-5350.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers

Hi I have a 2006 Lincoln navigator the air suspension pump will not turn on the vehicle dynamics module is not turning on the pump relay because in the pid data the drivers door says it is ajar when it is...

Hey Jeff, any U- codes stored in any modules ?
U1900 Missing CAN message(s) Door(s) ajar, PRNDL, 4x4, instrument cluster (IC), running boards, vehicle speed REFER to Section 418-00 . U2023 Invalid CAN message(s) Door(s) ajar, PRNDL, 4x4, instrument cluster (IC), running boards, vehicle speed REFER to Section 418-00 .
L4 CHECK THE VDM FOR DOOR AJAR INPUT
  • Key in ON position.
  • Monitor VDM door position status PID.
  • Close all doors, liftgate, liftgate glass and power running boards.
  • While observing the diagnostic tool, open and close one door.
  • Does the door status PID change between CLOSED and AJAR states?
When you open an close the driver door you have no PID change ,right ?
L4 CHECK THE VDM FOR DOOR AJAR INPUT
  • Key in ON position.
  • Monitor VDM door position status PID.
  • Close all doors, liftgate, liftgate glass and power running boards.
  • While observing the diagnostic tool, open and close one door.
  • Does the door status PID change between CLOSED and AJAR states?
The door ajar input is an input to the Vehicle Security Module , then transmitted over the bus ! You'll have to find a diagram for the med. speed CAN data bus .
1helpful
1answer

I am getting a close battery door on the display but the door is closed. I have removed the battery and closed it back but it didn't help. any suggestions?

I don't know why you would be getting that error. As far as I remember the mc70 didn't have a battery door switch. It just closes and has the little wings that clamp the door into position. Here is the manual for your model http://peachinfo.net/downloads/mc70UserGuide.pdf

Page 20 shows the door and operation of the door is on 24. Try using a different battery.

Try doing a cold boot of the device after changing the battery. Maybe there is a third party device driver for a aftermarket door installed. It might not be reading the device correctly.
0helpful
1answer

Why is my kodak 5250 showing error code 3807?

Error: "System status failed" (3807) Published 08/25/2010 11:38 AM ' Updated 08/28/2012 05:23 PM ' Answer ID 1249
How do I resolve the error message "System status failed" (error code 3807)?
  1. Disconnect the power adapter from the printer.
  2. Wait 30 seconds to allow the printer to reset.
  3. Connect the power adapter to the printer. Turn the printer on if necessary
If the error continues:
  1. Open the printer access door.
  2. Remove and install the printhead two times.
  3. Close the printer access door.
  4. Wait until the printer is ready to use.
If the error is resolved, upgrade your printer firmware:
  1. Locate and select the firmware for your printer.
  2. Follow the on-screen instructions to install the firmware.
If the error is not resolved, contact us.
2helpful
1answer

Washing machine Siemens iq300 has error CL in display (status) & can't be used

This means that the door is not being closed. It might be a bad door switch.
2helpful
1answer

Could not get pm power status when turn on Mc9090

That error occurs when the LCD module is disconnected from the keyboard module. Check the ribbon cable/connector between the two. It has to be connected by hand prior to reassembling the unit.
0helpful
1answer

Hello, I have a Turbochef tornado oven, while operation i am getting a Fault code Close door error and it keeps on coming while closing the door with a beep . Can anyone please try to resolve the error...

seems like your primary switch isn't closed correctly or it might bad.
step to trouble shoot
OVEN HAS 5000 VOLTS MOVING INTO IT PLEASE BE CAREFULL
1.press back key to turn off the oven.
2.Open left side pannel.
3.press 'back' and 'enter' key together.Then, enter 9428 and then press enter.
4.You will be directing to an testing screen.At the bottom of thetesting screen there are many alphabets.In which you can see 'P' ,'S' and 'M' .
5.Open the door and watch what happened to alphabet 'P'.I meant to say that when door open alphabet will highlited ,and when closed its seems an regular 'P'
6.open door and close the door .And also keep an eye on the primary switch at the top left corner of the oven where the door latches engaged.If it engaged very nicely and you still see an highlited 'P' in the testing screen then REPLACE THE PRIMARY SWITCH OR IF SWITCH IS OKAY THEN CHEK THE WIRING UPTO MAIN BOARD.
7.If switch doesn't latches properly then adjust switch ,by lossning the screw and aligned it properly.
PLEASE LET ME KNOW IF YOU KNOW HOW TO USE MULTIMETER,SO I CAN EXPLAIN YOU HOW TO CHECK THE SWITCH.
ALSO PLEASE RATE MY ANSWER.
THANKS
3helpful
3answers

Printer error error code 3807

From the kodak website:

Error "System status failed" (3807)

How do I resolve the error message "System status failed" (error code 3807)?

To resolve the error message "System status failed" (error code 3807):
Disconnect the power adapter from the printer.
Wait 30 seconds to allow the printer to reset.
Connect the power adapter to the printer. Turn the printer on if necessary

If the error continues:
Open the printer access door.
Remove and install the printhead two times.
Close the printer access door.
Wait until the printer is ready to use.

If the error is resolved, upgrade your printer's firmware.

If the error is not resolved, contact kodak.

Hope this helps
13helpful
2answers

Not ABLE to switch on MC9090. tried replacing the battery . Held the power button for 2 mins . nothing is working. Is there any key combination to start the reader ? please help.

I know it may be a little late now since you're question was a couple months ago, but I have had this problem with some 9090's before too where a warm boot (holding the power button down) will not bring them up, but a cold boot always does (unless of course it truly is defective - that's not usually the case though).

To do a cold boot, pop the battery out part of the way until it "catches" (you'll know what I mean if you have an MC9090 and try it). Then hold down the trigger and the power button simultaneously while pushing in the battery all the way. Once the battery has been pushed in, release the power button and the trigger.

This should cause the MC9090 to boot up fine. Make sure you release the trigger after doing the steps above. Sometimes people don't do that, and this causes the MC9090 to go into an infinite warm boot where it just continuously reboots over and over. The only way to get out of it is to cold boot again, but this time release the trigger in time.

Thanks,

Brad Radaker
Radicomm (makers of QuickTalk - push-to-talk over WLAN for the MC9090)
www.radicomm.com
17helpful
5answers

My MC9090-G scanner is stuck in boot mode. I've tried a cold boot and warm boot and nothing works.

Actually if it is continuously rebooting, it is usually because someone was holding down the trigger through a cold boot process. That's what puts it into this continuous reboot loop. To get out of it do a cold boot again (pop the battery part of the way out, hold down the power button and trigger simultaneously, and then push the battery back in while the power button and trigger are still down). But as soon as you push in the battery to the point where you hear it click, release the trigger. If you hold it in too long, the unit will start continuously rebooting.

Thanks,

Brad Radaker
Radicomm, Inc. (makers of QuickTalk - push-to-talk for the MC9090)
www.radicomm.com
1helpful
3answers

Close door or insert cartridge

check in your backside of printet any paper jam
pull that paper thats it.
also pull the cartridge and refix again it
Not finding what you are looking for?

3,638 views

Ask a Question

Usually answered in minutes!

Top Zebra Computers & Internet Experts

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Brad Brown

Level 3 Expert

19187 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Zebra Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...