Question about Honeywell HE220A1019 Whole House Humidifier Humidifier

Open Question

Where in colorado can I buy a kip inc. u147112 solonoid valve?

I'm looking to buy a replacement valve near Broomfield, colorado

Posted by Anonymous on

Ad

3 Suggested Answers

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

123456798abc

  • 1 Answer

SOURCE: he220a honeywell humidifier water actuator valve broke

The screw does turn and will open the valve, take the hex nut off and turn the screw to see if water leaks between the valve portion and the hexnut housing. They used that same valve on many models, including the newer models. Make sure you are getting water to the valve.

Posted on Dec 02, 2008

Ad
MNfisherman

Nate Stansfield

  • 11896 Answers

SOURCE: Does anyone know where to get replacement filters

You can get them from honeywellcentral.com
filters-fast.com
nextag.com
amazon.com

Posted on Dec 21, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Water runs continuosly on my Honeywell Envirocaire Elite system, no matter what setting I have the automatic humidity control set at, should I try replacing the Kip valve #3703?


Try to disconnect the main power to the unit and if the water valve is still open and water is running, you have a bad valve (the valve stuck open). Tap on the valve body it may help on sticking it, if not replace it.

Feb 17, 2013 | Honeywell HE360A1027 Whole House...

1 Answer

Should the solenoid should close and stop the water flow when no power/open circuit?


Yes, this solenoid is "Normally Closed". That means that when energized, the solenoid opens the valve to allow water to flow. Otherwise it is closed. Unfortuneately, that doesn't always happen, and there soes not seem to be a pat answer as to why. I spoke with the mfgr (Kip) and they offered plentyof "maybe's" but nothing firm.

What's worse is that I can not find any one or store that stocks or sells these, and Kip's lead time is 4-6 weeks.

Dec 28, 2010 | Honeywell HE220A1019 Whole House...

1 Answer

I have a Honeywell humidfier HE 220A with a KIP U147112 pump. A lot of water bypasses the humidifer and I use 5 gal. in 24 hours. is there an adjustment on the pump to reduce the flow, or some other...


I have a Honeywell humidfier HE 220A with a KIP U147112 valve. Will turning the large screw head on the valve decrease the volume of water flow through the humidifier. Too much water is being wasted.

Dec 20, 2010 | Honeywell HE220A1019 Whole House...

1 Answer

Water runs without furnace running


If this is a new problem, on an existing humidifier, then it is most likely a bad solonoid valve. This is the valve that the water line is connected to, and it controls the flow of water to your humidifier.

If this is a problem on a newly installed humidifier, it is possible to have wired the humidifier directly to the transformer power, and therefore holding the valve open all the time.

Hope this helps

Nov 03, 2010 | Aprilaire 700 Humidifier

1 Answer

Does anyone know where to get replacement filters for the KIP U147112-24/60 valve?


You can get them from honeywellcentral.com
filters-fast.com
nextag.com
amazon.com

Dec 21, 2009 | Honeywell HE220A1019 Whole House...

1 Answer

Water will not shut off even when unit unplugged. With power on the solonoid sounds like it is going on and off but not...


need a new solinoid and valve probably has mineral build up in valve can't close. Turn off at line tap on your water pipe. clean or replace

Nov 28, 2009 | Air King Humidifiers

1 Answer

No water flow in humidifier


clearly your water pump is broken. or you solonoid

Nov 11, 2009 | Aprilaire 600 Humidifier

1 Answer

Hello, I have an Aprilaire 350, and the "solonoid" needs to be replaced. Exactly what is the part #, I would like to do this myself


I dont knnow the part #, but to be honest with you every single residential humidifier with a soleniod valve uses the exact same valve. Same 1/4' inlet and oulet and same 2 hole mounting pattern. The only difference between humidifiers is basically the bigger the unit the more humidity it can produce. Hope this helps. Steve

Dec 22, 2008 | Aprilaire 350 Humidifier

3 Answers

He220a honeywell humidifier water actuator valve broke


The screw does turn and will open the valve, take the hex nut off and turn the screw to see if water leaks between the valve portion and the hexnut housing. They used that same valve on many models, including the newer models. Make sure you are getting water to the valve.

Nov 26, 2008 | Honeywell HE220A1019 Whole House...

2 Answers

Aprilaire 600 humidifier solonoid valve chattering in sync with d10 led


I fixed my problem by ordering a new control unit (model 56) from IAQSOURCE. Installing the control unit took a few mintues, and once the new control module was installed, I've had no more problems. The URL is as follows: http://www.iaqsource.com

Oct 12, 2007 | Aprilaire 600 Humidifier

Not finding what you are looking for?
Honeywell HE220A1019 Whole House Humidifier Humidifier Logo

Related Topics:

285 people viewed this question

Ask a Question

Usually answered in minutes!

Top Honeywell Humidifiers Experts

Dennis

Level 3 Expert

962 Answers

Simon Benzekri

Level 1 Expert

21 Answers

jdthefixer

Level 3 Expert

746 Answers

Are you a Honeywell Humidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...