Ive got a rheem tankless water heater less than a year 4 days ago had power failure now the heater wont come on remote does not work and keeps blowing 3 amp fuses

3 Answers

Michael Fech

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Sep 07, 2015
Michael Fech
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Sep 07, 2015
Answers
1
Questions
0
Helped
7907
Points
7

Not for sure what your root cause was and I know it's a little late but I just suffered this same exact scenario on the same water heater. Storms came through, power went out, power came back on and the water heater keeps blowing the 3 amp fuses now. I removed all the cables and plugged them back in one at a time. When I plugged in the Fan Motor connector the fuses blew. Installed new fuses with the connector out, the Fan Motor was putting out 150 VDC through the connector port (on main control). I pulled the control from the unit and Q1 is visible blown and disintegrated on the control board. Obvious control design issue. I've ordered a new control and will put a surge protector on the heater now when the new control comes in. Very disappointed that this was not caught in controls testing within the manufacturers facility. New control is not very cheap. Half the cost of a new Heater. Hopefully the Fan Motor survived the high voltage with the fuses blowing. I'm putting this here for anyone else that suffers the same issue on this water heater or the Richmond equivalents as they use the same control.
rheem water heater rtg95dvn keeps blowing 3 amp fu - rheem-water-heater-rtg95dvn-keeps-lig2cnfgd44b3pejpipwueov-2-0.jpg

David Spradling

Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

  • Rheem Master 13,522 Answers
  • Posted on Nov 01, 2020
David Spradling
Rheem Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

Joined: Feb 25, 2015
Answers
13522
Questions
0
Helped
929064
Points
28390

Try disconnecting ignitor leads if then ok replace

Ad

Gene Haynes

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Rheem Master 5,391 Answers
  • Posted on Jul 31, 2012
Gene Haynes
Rheem Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 07, 2012
Answers
5391
Questions
0
Helped
2605844
Points
14124

Call Rheem
1-800-432-8373
They might ask you to contact the installer. If you installed it yourself ... well that is problematic. For example if vent condensation drain was not installed correctly, the condensation can drip down into the unit causing acidic water that will shorten life of heat exchanger.
Make sure there is affordable qualified service in your area before buying tankless water heater.
Avoid wallet thickness error.
http://waterheatertimer.org/pdf/Tankless-WT-Error.pdf
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html
Don't forget to keep up with yearly maintenance, and tankless cannot be exposed to more than 11 grains hardness in water.
http://waterheatertimer.org/pdf/Tankless-maintenance.pdf
And if you need a service manual for your Rheem tankless, well that is problematic since Rheem does not have service manuals ... might try reading Bosch or Bradford white service manuals.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

5 Related Answers

Anonymous

  • 332 Answers
  • Posted on May 29, 2009

SOURCE: rheem tankless water heater wont lite

the system was not sized properly, you need to have a 3/4 gas line to the unit for the volume of gas it needs, the tankless water heaters need to have every bit of gas that is says, it sounds like who ever installed di not make sure you had enough gas comming in the house, you might have to either have a new meter installed or run the gas lind directly from the meter to the water heater and cap off the gas line thats there

Ad

Anonymous

  • 949 Answers
  • Posted on Apr 07, 2009

SOURCE: No hot water from tankless water heater. Bliniking Readout

http://www.rheemtankless.com/content/tankless/rheem/help.shtml

This is there website.Above.
Use the live chat to ask them, the code you listed does not seem to correspond to there code list, the only code that does is code 76,
which is a problem with the remote control not talking to the unit.
So your best bet is to tell them the error.

Anonymous

  • 2 Answers
  • Posted on May 30, 2009

SOURCE: My Rheem Tankless Hot Water Heater is installed, but is it not attempting to start. The digital display keeps blinking 82, 0, 82 , 0 ...?

If this is a new board and Altidude chip with power on set dip switch 1 and 2 to on. Then press and hold adjust button until on board blinks fast then and you will see dashes on LCD display. Set dip switches 1 and 2 back to off. Turn on remote unit and you should see 100F. With any luck you are good to go.

Anonymous

  • 244 Answers
  • Posted on Nov 01, 2009

SOURCE: Rheem water heater turns off by its self

Flashing code 76 is lost communication between the remote and the burner control assembly CCA (circuit card assembly). The CCA is still under warranty if purchased within the last 3 yrs. Contact Rheem customer service and have your Mod. and S/N available....explain to the agent you are recieving - flashing code 76...they'll walk you through the process.

Lickzee

  • 68 Answers
  • Posted on Jul 31, 2010

SOURCE: rheem gas tankless water heater with error code c4 13

problem is inside burner compartment o2 sensor dirty or block..need to have a qualify technician clean it.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

What is causing electric tankless hot water heater to be needing red button reset often?

PDF]Tankless Electric (RTE) Troubleshooting - Rheem

www.rheem.com/docs/FetchDocument.aspx?ID=87d15e35-5adf-4e9f...
Tankless Electric (RTE) Troubleshooting. Technical Competence .... For four chamber units (RTE18 & 27) go to paragraph 4T. 9. Conduct OHMS resistance ...

Rheem RTE 27 Series ' Use and Care Manual

https://www.manualowl.com/m/Rheem/RTE-27-Series/Manual/296033
Rheem RTE 27 Series ' Use and Care Manual - Page 1. Use & Care Manual Electric Tankless With Installation Instructions for the Installer Water Heaters The ...
0helpful
1answer

Blowing fuses on rheem rtgh 84dv

Call service technician
Check polarity of 120 volt outlet
Call Rheem for new PC board
If the 3A glass fuse located on PC board is blowing, then something is drawing too much current or shorted on board... problem is probably bad PC board
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html

Gene

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

No power to unit

Copy following link for tankless troubleshoot resources:
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html#fuse
Tankless are not protected from surge, but there is a 3-5 amp glass fuse located on circuit board.
Check outlet with circuit analyzer, and multimeter

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Rheem Pronto water heater Error code E1

Before calling service technician, open following link for troubleshoot resources include Rheem chat, error codes, and regular maintenance manual, and possible product manual:
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html
http://waterheatertimer.org/pdf/Tankless-maintenance.pdf

Clean the water filter as shown in product manual.
Error E1 is not specifically shown for Rheem/Pronto tankless.
1 is usually related to water flow.
E errors are related to temperature, so E1 can be temperature sensor failure on hot water pipe.
E errors can be loose/bad wiring or part failure.

Error codes are considered start-point for troubleshoot.
Each tankless manual recommends cleaning the water filter monthly, deliming heat exchanger yearly, and cleaning combustion chamber and burner parts yearly.
Regular maintenance can prevent most common error codes, but the cost and nuisance will outweigh expected $1-8 monthly savings on gas bill.
The requirement for continual maintenance should signal folks that tankless are not effortless hot water as described in tankless promotion.

Solve most tankless problems same day, yourself, any brand, using minimal tools for about $350.
http://waterheatertimer.org/How-to-install-gas-water-heater.html
0helpful
1answer

I have a poloma model/ pt62-42pvn its flashing error code c4 76 i have had no hot water for six days now need help

1) Before calling service technician who can test parts, open following link for Rheem resources including error codes, Rheem chat and phone number, possible manual:
If local technician cannot solve problem, Rheem can probably recommend a person.
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html

2) Error codes are start-point for troubleshooting.

3) Multiple error codes can indicate PC board failure.
If your computer motherboard fails, most people feel the computer is compromised even after motherboard replacement.

4) Error code C7-76 is communication error with remote, and can include bad remote, bad wire to remote, loose wire, or bad PC board.
http://waterheatertimer.org/pdf/Rheem-error-code-C7-76.pdf

5) Error C4-13 can include part failure, vent problem, oxygen depletion, and can also include PC board failure.
http://waterheatertimer.org/pdf/Error-code-13.pdf

6) Tankless routine maintenance manual:
http://waterheatertimer.org/pdf/Tankless-maintenance.pdf

7) Some posts about tankless concede that qualified technician was unable to repair unit.
Solve most tankless problems yourself, same day, for about $350.
http://waterheatertimer.org/How-to-install-gas-water-heater.html

8) Take a moment and rate answer:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

Rheem rtg-53pvn will not turn on and heat water when hot water is turned on - no error code - remote just goes off like the power is off

Before calling service technician, open following link for Rheem troubleshooting resources including Rheem chat:
Rheem will suggest you catch up on required yearly maintenance which would cover most causes for common error codes, and cover cause of no error code including plumbing problem or loose wire or PC board failure. Combination of problems can also cause failure and these issues would be covered by general maintenance.
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html
Solve most tankless problems same day for $350
http://waterheatertimer.org/How-to-install-gas-water-heater.html
0helpful
1answer

Unit wont run and thers no error code

1) Rheem offers on-line chat, which you rarely see for typical tank-type water heater
http://www.rheem.com/products/tankless_water_heaters/customer_support/
http://www.rheem.com/hrc.aspx

2) Call local service technician, and put that person in your rolodex-wallet for future help.
When technician arrives, ask that person for tips and tricks keeping unit working with regular maintenance.
They will gladly offer yearly service.

3) Read manual several times get accustom to yearly maintenance required for tankless water heaters. Tankless water heaters are maintenance heavy. All costs are energy.

4) Read manual several times and notice word troubleshoot appears many times.
Since tankless are complicated machines, many internal and external factors can affect operation, especially as unit ages.

5) Look at label on unit to identify exact product number. Identify same/similar product at Rheem, and become familiar with Rheem website
http://www.rheem.com/products/tankless_water_heaters/

6) Read other question/answers at fixya about Rheem tankless to become familiar with the tankless era
http://www.fixya.com/tags/rtg_74pvn

7) Install DIY tank-type gas water heater and avoid the whole headache
http://waterheatertimer.org/How-to-install-gas-water-heater.html

8) Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

BOUGHT THE UNIT IN JULY 2009 WORKED FINE UP UNTIL THREE DAYS AGO WHEN I RUN THE HOT WATER IT RUNS FOR A FEW MINUTES THEN SHUTS OFF.

1) Rheem offers on-line chat, which you rarely see for typical tank-type water heater
http://www.rheem.com/products/tankless_water_heaters/customer_support/
http://www.rheem.com/hrc.aspx

2) Call local service technician, and put that person in your rolodex-wallet for future help.
Ask technician for tips and tricks for keeping unit working and needed maintenance.
They will gladly offer a yearly service.

3) Read manual several times to get accustom to yearly maintenance required for tankless water heaters. Tankless water heaters are maintenance heavy. All costs are energy.

4) Read manual several times and notice word troubleshoot appears many times.
Since tankless are complicated machines, many internal and external factors can affect operation, especially as unit ages.

5) Look at label on unit to identify exact product number. Identify same/similar product at Rheem, and become familiar with Rheem website
http://www.rheem.com/products/tankless_water_heaters/

6) Read other question/answers at fixya about Rheem tankless to become familiar with the tankless era
http://www.fixya.com/tags/rtg_74pvn

7) Install DIY tank-type gas water heater and avoid the whole headache
http://waterheatertimer.org/How-to-install-gas-water-heater.html

8) Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.
7helpful
5answers

Paloma tank less water heater flashes code C4 13 and we have no hot water?how to fix it?

I had the same problem with my Paloma a year and a half after installation...contacted Rheem customer service (800-432-8373) and they recommened a local installer in my area. The technican diagnosed the problem as the "flow control valve"; he managed to get Rheem/Paloma to cover the part under warranty...I only had to shell out the money for the install.
Not finding what you are looking for?

7,917 views

Ask a Question

Usually answered in minutes!

Top Rheem Water Heaters Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you a Rheem Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...