These are pretty simple units. If you look on the back you will see a schematic. More or less there is an overload protector in series with the thermostat in series with the compressor. If the overload protector is not open and there is still no 120VAC at the compressor with the thermostat turned all the way up then the answer is a bad thermostat. If there is 120VAC at the compressor and it is not running then the compressor is bad. That's about it.
SOURCE: should my haier 1.7 compact refrigerator run
this is a thermoelectric model and runs on a peltier junction. It will always have the fan running. That is the only moving part.