I have a U-LIne Combo 75 that is not getting cold. The light goes on, so I know it has power. How can I tell if it is a compressor or thermostat problem? The thermostat has three wires: Blue, Yellow and Red. If I short any of these wires, will the compressor turn on? Which wires and how long before the compressor turns on? What is the part number of the thermostat if I need to order on?
The 3 wires is. Yellow on terminal 2 (common) red wire on terminal 1 (icemaker) and Blue on terminal 3(compressor and fan). If you bypass the yellow and blue then the compressor and fan should run. If you bypass the red and yellow then the icemaker will advance. Hope this helps.
Hi there,
i have some procedure in troubleshooting a ref., as follows:
1. check if the compressor will run when you plug the ref in the outlet/power.
a. if the compressor run and it will not produce the cold or heat. then the problem is, the system of your ref. has a leak. it lost all the freon charge into the system. find a near service center in your area.
b. if the compressor run and it stop. unplug your ref. from power.
c. if the compressor will not run, unplug your ref from power and then check the follow: